Summary of the content on the page No. 1
PROGRAMMING
R
INSTRUCTIONS
Publicly traded on NASDAQ Symbol: NSSC
HARDWIRE WIRELESS
GEM-P3200
CONTROL PANEL/COMMUNICATOR
Programming the GEM-P3200 Control Panel with the
"Classic" GEM-RP1CAe2 Keypad and the "K Series" GEM-K1CA Keypad
GEMINI
GEMINI
SYSTEM READY
SYSTEM READY
01/01/06 12:00 AM
01/01/06 12:00 AM
NEXT/YES
NEXT/YES
P
A 1 2 3 E R 1 2 3
D U PRIOR/NO
PRIOR/NO
F B 4 5 6 Q
B 4 5 6
AREA
AREA
C 7 8 9 0 G C 7 8 9 0
Summary of the content on the page No. 2
THIS MANUAL INCLUDES FEATURES WHICH ARE ONLY AVAILABLE IN CONTROL PANEL FIRMWARE VERSION 50 OR LATER. IMPORTANT NOTE This manual supports the keypad programming of the GEM-P3200 control panel with the NAPCO "classic" GEM- RP1CAe2 keypad as well as the GEM-K1CA "K Series" keypad. The new "K Series" GEM-K1CA model offers the new STAY and AWAY buttons with simplified functionality, along with the new MENU and ENTER buttons. Note: While the instructions in this manual are depicted using the
Summary of the content on the page No. 3
Page 3 WI818G 10/05 TABLE OF CONTENTS SYSTEM OPTIONS (ADDRESS 2420-2422, 3874, 3905, 3880-3881) .................35 IMPORTANT NOTE ...................................................... 2 ALARM/TROUBLE REPORTING CODES (ADDRESS 3880-3881) .....................35 SYSTEM OPTIONS (ADDRESS 3882-3901, 3903-3905 & 4084) .........................36 CHANGES FROM PREVIOUS EDITION ..................... 2 KEYPAD OPTIONS (ADDRESS 2425-2446) .......................................................
Summary of the content on the page No. 4
Page 4 WI818G 10/05 SYSTEM PROGRAMMING OPTIONS INTRODUCTION The GEM-P3200 control panel may be programmed by various means, each of which will be covered in detail in the sections that follow. Keypad displays shown are for a GEM-K1CA (v.8), the recommended keypad for programming. Downloading From a Computer. This is the preferred method of programming. The panel may be downloaded from (or uploaded to) an IBM PC-compatible computer, either locally or remotely. Napco's PCD3000
Summary of the content on the page No. 5
EASY MENU DRIVEN PROGRAM MODE Page 5 WI818G 10/05 EASY MENU DRIVEN PROGRAM MODE DEALER PROGRAM - PRELIMINARY INFORMATION Only Keypad #1 may be used for both dealer and user programming, however this keypad may be located in any area. The Master Security Code is printed on the panel’s microprocessor can. Use this code to enter the Dealer Program Mode to program a custom Dealer Security Code. Record the number, then remove the code label to prevent unauthorized access to the panel.
Summary of the content on the page No. 6
Page 6 WI818G 10/05 GEM-RP1CAe2/GEM-K1CA Keypad Easy Program Menu To create a custom program using the GEM-RP1CAe2/GEM-K1CA keypad, simply answer the following questions and re- cord your information on the Easy Menu Programming Worksheet. In each of the following steps, press R to set cursor, the NEXT/YES button to go forwards, the PRIOR/NO button to go backwards, U to save and C twice to exit at any time. Total Number of Zones in Area 1 (New Program Only) #of Zns in Area1 •
Summary of the content on the page No. 7
GEM-RP1CAE2/GEM-K1CA KEYPAD EASY PROGRAM MENU Page 7 WI818G 10/05 Chime 2 Zones in Area 1 (New Program Only) Chime 2 Zones • Enter the zone numbers which are to be used as Chime 2 Zones. Enter Zone # °° • Valid entries are from 01 to 48. Directly enter each zone number, including leading zeros. (Direct Entry) • Press U to save and then repeat for any additional zone(s), Press the NEXT/YES button to proceed. NOTE: A chime time of 2 seconds will be automatically programmed.
Summary of the content on the page No. 8
Page 8 WI818G 10/05 Enable SIA CP-01 Features? Enable SIA CP-01? • Press the NEXT/YES button to enable. Y/N • Press the PRIOR/NO button to continue. The SIA CP-01 Features are designed to reduce the incidence of false alarms. NOTE: Do not enable (Press YES or NO) unless reporting, otherwise system trouble Fail to Communicate may occur. Number of Keypads in Area 1 # Area 1 Keypads • Enter the total number of Keypads to be installed in Area 1
Summary of the content on the page No. 9
GEM-RP1CAE2/GEM-K1CA KEYPAD EASY PROGRAM MENU Page 9 WI818G 10/05 Central Station Receiver 1 Account Number Central Station • Enter an account number of up to four digits. Account # (____) • Press 0 through 9 for digits 0–9, and G 0 for a blank (•). • Press U to save and press the NEXT/YES button to proceed. (Direct Entry) NOTE: Central Station Receiver 2 and 3 Account Numbers must be entered in Direct Address Pro- gramming. See CS Reporting Options.
Summary of the content on the page No. 10
Page 10 WI818G 10/05 Enter User Codes (Press the R button to set cursor.) Enter up to 48 User Codes with User Options, Authority Level and Access Enter user code 001 123 -E3- Control Options (if necessary) for each code. Refer to the tables below and on the next page for available data entries for User Options, Authority Level and User# User Code Access Control Options. Note: All 48 Users must be assigned to areas in “User Area Options” (Address 2455-2502) i
Summary of the content on the page No. 11
GEM-RP1CAE2/GEM-K1CA KEYPAD EASY PROGRAM MENU Page 11 WI818G 10/05 USER AUTHORITY LEVEL NOTES: KEYPAD DISPLAY FUNCTION MENU * Minimum Level required to access function FUNCTION LEVEL* ** Level-3 Code with appropriate user option DISPLAY ZN FAULTS 1 *** Requires Dealer Code DISPLAY ZN BYPASSED 1 DISPLAY ZN DIRECTORY 1 ACTIVATE BELL TEST 1 USER OPTIONS DISPLAY PHONE #’S 1 OPTIONS EXPLANATION DISPLAY SYS TRBL 1 Disabled User Code not active in this area. DISPLA
Summary of the content on the page No. 12
Page 12 WI818G 10/05 Enter Proximity Card Users (FOR ACM USE ONLY). (Press the R button to set cursor). See WI1221 for more information. Enter user code 001 123456- 6- Enter up to 48 Proximity Cards with User Options, Access Level and ACM Area (if necessary) for each card. Refer to the tables below and to WI1221 for User# User Code more information. Press the R button to set the cursor to the User Code. Use the number buttons 1 through 9 to enter a 6
Summary of the content on the page No. 13
GEM-RP1CAE2/GEM-K1CA KEYPAD EASY PROGRAM MENU Page 13 WI818G 10/05 RF Transmitter Points (Press R to set cursor.) ZN# XMIT#+CS P For each transmitter enter: (For wireless systems only. Also see Quick Method, which follows) Zn01- 000000:0-0 • The zone number (01–48) to which the transmitter will be mapped. Zone # Xmitter Check Point Mapped to ID Sum # • The 6-digit RF ID # and 1-digit checksum numbe
Summary of the content on the page No. 14
Page 14 WI818G 10/05 KeyFob Transmitters as Zone Input Devices DATA AUX 1/AUX 2 OPTIONS (Refer to display above: press the PRIOR button to go backwards). ENTRY Each of the 4 keyfob buttons can be assigned to a zone. For example, On button = point 1; Off button = point 0 None 2; A1 = point 3; A2 = point 4. Up to 48 keyfobs (using 1 button) or 24 keyfobs (using 2 buttons) or 14 keyfobs 1 Relay Group 1 Toggle (using all 4 buttons) or any combination up to a maximum of 48 controlled
Summary of the content on the page No. 15
DIRECT ADDRESS PROGRAM MODE Page 15 WI818G 10/05 DIRECT ADDRESS PROGRAM MODE DIRECT ADDRESS OVERVIEW Direct Address Programming allows you to go directly to the address locations (up to 4095) and change the data entries manually in order to customize your control panel options. Whereas the Easy Menu Program Mode guides you through limited selections to get you started, Direct Address Program Mode allows you to change all options directly. It con- sists of up to 4095 address locations
Summary of the content on the page No. 16
Page 16 WI818G 10/05 ZONES 1 8 ZONES 9 16 ZONE FEATURES ADDR Z1 Z2 Z3 Z4 Z5 Z6 Z7 Z8 ADDR Z9 Z10 Z11 Z12 Z13 Z14 Z15 Z16 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 6 7 8 Exit/Entry Follower 1218 1318 PROGRAM THE DATA ENTRIES 1. Enter the panel's Dealer Security Code, then press R. 2. Answer NO to all questions until “ACTIVATE PROGRAM Y/N” is displayed; then press YES. NOTE: If you pass “ACTIVATE PROGRAM”, scroll backward using B. 3. Press C to enter th
Summary of the content on the page No. 17
DIRECT ADDRESS PROGRAM MODE Page 17 WI818G 10/05 advance to the data field. 5. Press 015. The numbers 015 will appear on the keypad display indicating the number of seconds entered. 6. Press U to save. Address 2406 is now programmed with a 15-second Abort Delay. 7. Enter another 4-digit address to continue programming or press C to exit and resume normal keypad operation. C) Hexadecimal Format Data such as Report Codes displays, accepts data by means of a Hexadecimal displ
Summary of the content on the page No. 18
Page 18 WI818G 10/05 PROGRAM THE DATA ENTRIES 1. Enter the panel's Dealer Security Code, then press R. 2. Answer NO to all questions until “ACTIVATE PROGRAM Y/N” is displayed; then press YES. NOTE: If you pass “ACTIVATE PROGRAM”, scroll backward using B. 3. Press C to enter the Address Program Mode. Address "0000" will display. 4. Press 0900 to access Address 0900. The existing data will display and the cursor will ad- vance to the data field. 5. Since you wish
Summary of the content on the page No. 19
SYSTEM DELAYS/TIMEOUTS Page 19 WI818G 10/05 SYSTEM DELAYS & TIMEOUTS (ADDRESS 0000-0002, 2402, 2406, 2414 & 3902) Aux. ADDRESS 2402 ABORT ADDRESS 2406 ENTRY ADDRESS 0002 ADDRESS 0000 ENTRY ADDRESS 0001 EXIT Output DELAY DELAY 2 DELAY 1 DELAY Access (sec.) (sec.) (sec.) Control (sec.) Timeout (sec.) [Default = 000] [Default = 030] [Default = 030] [Default = 060] [Default = 000] Telephone ADDRESS 2414 Line Test Delay (x15 sec.) Sele
Summary of the content on the page No. 20
Page 20 WI818G 10/05 SYSTEM DELAYS & TIMEOUTS (ADDRESS 2400, 2401, 2403-2405, 4082 & 4083) Reset Output ADDRESS 2400 Aux. Output ADDRESS 2401 Burg. Alarm ADDRESS 2403 Pulse Alarm ADDRESS 2404 ADDRESS 2405 Fire Output Timeout Timeout Output Output Timeout (min.) (min.) Timeout Timeout (min.) (min.) (min.) [Default = 000] [Default = 000] [Default = 015] [Default = 015] [Default = 000] Report ADDRESS 4082 Cancel 1. Select delay/timeout (0-255 min.).