Napco Security Technologies GEM-X255 user manual

User manual for the device Napco Security Technologies GEM-X255

Device: Napco Security Technologies GEM-X255
Category: Home Security System
Manufacturer: Napco Security Technologies
Size: 0.3 MB
Added : 12/17/2013
Number of pages: 40
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Napco Security Technologies GEM-X255. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Napco Security Technologies GEM-X255.

For your convenience

If looking through the Napco Security Technologies GEM-X255 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Napco Security Technologies GEM-X255 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Napco Security Technologies GEM-X255 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Napco Security Technologies GEM-X255 User manual - Online PDF
Advertisement
« Page 1 of 40 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Napco Security Technologies GEM-X255 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Napco Security Technologies GEM-X255. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

OPERATING GUIDE for the
GEM-X255 Security System
GEMINI
SYSTEM ARMED
01/01/00 12:00 AM
E
A 1 2 3
J
F
B 4 5 6
G
C 7 8 9 0
COMPUTERIZED SECURITY SYSTEM
© NAPCO 2001 DESIGN PATS. PENDING
1
GEM-X255_OI273_USER.pub Tuesday, September 10, 2002 13:14
page 1
STATUS
ARMED

Summary of the content on the page No. 2

INTRODUCTION The GEM-RP1CAe2 is a “smart” future reference. Check the Glossary for Regardless of how your system has user-friendly, menu-driven keypad an explanation of terms that may be been configured, rest assured that it has designed for your Napco GEM-X255 unfamiliar to you. been carefully designed and engineered control panel. The keypad is interactive. You'll probably find subjects to the highest industry standards. To Its alphanumeric screen will not only mentioned in this booklet that d

Summary of the content on the page No. 3

TABLE OF CONTENTS TABLE OF CONTENTS TO SILENCE AN ALARM, ENTER YOUR CODE, AND PRESS J. Section Page KEYPAD CONTROLS & INDICATORS............................................ 4 FOR SERVICE, CALL: _____________________ SETTING THE ALARM (ARMING) WHEN LEAVING....................... 6 CENTRAL STATION: ______________________ PROTECTING YOURSELF WHILE ON THE PREMISES................ 8 EXIT DELAY: _____________________________ TURNING OFF THE ALARM (DISARMING) WHEN RETURNING .. 10 ENTRY DELAY: _____

Summary of the content on the page No. 4

KEYPAD CONTROLS & INDICATORS 1 GEMINI 2 SYSTEM ARMED 01/01/00 12:00 AM 3 7 8 A 1 2 3 E 4 J 9 B 4 5 6 F 5 10 C 7 8 9 0 G 6 11 COMPUTERIZED SECURITY SYSTEM 12 4 GEM-X255_OI273_USER.pub Tuesday, September 10, 2002 13:14 page 4 ARMED STATUS

Summary of the content on the page No. 5

KEYPAD CONTROLS & INDICATORS Window. Displays system status 5 BYPASS Button. (1) Deactivates INSTANT Button. (1) Cancels 1 10 messages, zone descriptions, etc. selected zones from the system. entry delay on Exit/Entry Zones, (2) Unbypasses a bypassed zone. causing an instant alarm upon STATUS Light. Lights (green) to violation. (2) Scrolls window 2 indicate that the system is ready RESET Button. (1) Resets display backward (PRIOR). (3) 6 for arming. If a zone is not secured various system troubl

Summary of the content on the page No. 6

SETTING THE ALARM (ARMING) WHEN LEAVING Arming the System SYSTEM READY 1 Check the keypad. The green STATUS light must be on in order to arm. If the green light is off, “ZONES FAULTED” will display in the window followed by the number and description of each faulted zone. Note each problem zone and secure EXIT TIME 060 it by closing a window, door, etc. When all zones are secure, the green STATUS PLEASE LEAVE NOW light will come on and the window will display “SYSTEM READY”. 2 Arm the system. En

Summary of the content on the page No. 7

SETTING THE ALARM (ARMING) WHEN LEAVING System Trouble SYSTEM TROUBLE If you attempt to arm with a “SYSTEM TROUBLE” display alternating with an indicated trouble SYS/TRBL code (e.g. “E02-00” (low battery); see SYSTEM TROUBLE ERROR CODES), a 3-second tone will sound at the keypad. The window will display “PRESS RESET KEY, CAN'T ARM SYSTEM”. If you cannot correct the problem immediately, pressing C will enable you to arm in this LOW BATTERY condition. Be sure to call for service as soon as possibl

Summary of the content on the page No. 8

PROTECTING YOURSELF WHILE ON THE PREMISES Bypassing Interior Zones BYPASSED SYSTEM READY Interior Zones, when bypassed, allow free movement within the home while the protection of armed perimeter zones is maintained. To bypass Interior Zones, press E and enter your User Code followed by D. Your system may have provisions for two groups of Interior Zones. (Optional) (Interior Groups programmed? !YES !NO) • Press E, followed by Dto Bypass Interior Group 1: [ ____________________________________

Summary of the content on the page No. 9

PROTECTING YOURSELF WHILE ON THE PREMISES Easy Exit (Optional - Easy Exit programmed? !YES !NO) Your system may have been programmed for Easy Exit, which allows a user to exit the premises while the system is armed. By activating Easy Exit while the system is armed, the Exit Delay countdown will take place, during which time you are permitted to leave through the exit door. The Easy Exit Delay time will be identical to the Exit Delay time the system gives you each time it is armed. This will a

Summary of the content on the page No. 10

TURNING OFF THE ALARM (DISARMING) WHEN RETURNING Disarming the System ENTRY TIME XXX Enter your premises through the Entry/Exit door. The keypad will sound a steady tone 1 DISARM SYSTEM to remind you to disarm the system before your Entry Delay time expires. 2 Enter your User Code and press D. The red ARMED light will go out, indicating that the system has been disarmed. INVALID ENTRY • If you enter an invalid code, the keypad will beep 4 times, signifying an error. Re-enter TRY AGAIN your

Summary of the content on the page No. 11

FIRE PROTECTION (Applicable only where local ordinance permits use of this alarm control panel for fire protection.) Fire-Zone Alarm FIRE FIRE ALARM If a fire is detected, “FIRE ALARM” will be displayed and the keypad sounder will pulse. 1 If a fire is in progress, evacuate the premises immediately! If necessary, call the Fire Department from an outside phone. 2 Press the C button to silence the keypad sounder. 3 If there is no evidence of a fire, enter your User Code and press Jto turn off the

Summary of the content on the page No. 12

FIRE PROTECTION Preparing a Fire Escape Plan 3. Each person tests his door. window. If the door is cool, brace your Even with the most advanced fire 4. Pretend the door is hot and shoulder against it and open it alarm system, adequate protection use the alternate escape exit. cautiously. Be ready to slam the door requires an escape plan. 5. Everyone meets outdoors at if smoke or heat rushes in. Crawl the assigned spot. through smoke, holding your breath. To prepare your plan, draw floor plans of

Summary of the content on the page No. 13

FIRE PROTECTION Floorplan Draw a plan of your premises in the space provided below. Floorplan 13 GEM-X255_OI273_USER.pub Tuesday, September 10, 2002 13:14 page 13

Summary of the content on the page No. 14

FIRE PROTECTION LIMITATIONS OF FIRE ALARM WARNING SYSTEMS Although a fire alarm system may be of a that start where smoke cannot reach conditioner, or other appliance, or by reliable and state-of- the-art design, neither it them, such as in chimneys, walls, roofs, passing traffic, etc. Alarm warning nor its peripheral detection devices can offer behind closed doors, etc.; (b) they may devices, however loud, may fail to warn guaranteed protection against fire. Any such not sense a fire on a diffe

Summary of the content on the page No. 15

KEYPAD FUNCTIONS The keypad can provide access to a wide assortment of utility functions. The functions are displayed in a prompting “YES/NO” format. 1 . To enter the Function Menu, press A • In all UL-listed or high-security installations, a valid User Code must first be entered followed by A. 2 To skip a function, answer NO (F) or A. 3 To select and execute a function, answer YES (E) or J. • Functions may be manually scrolled forward or backward using A and B, respectively. • To return to

Summary of the content on the page No. 16

KEYPAD FUNCTIONS Activate Bell Test? Activates the alarm (while disarmed) for about 2 seconds and performs ACTIVATE a battery test. If the alarm does not sound, call for service. BELL TEST Y/N • If the battery is low, a “LOW BATTERY E02-00 SERVICE” will appear in the display indicating a low battery condition. Allow 24 hours for the battery to recharge. If the trouble continues, call for service. Display System Troubles? (Optional) Displays 1- or 2-digit error code along with a DISPLAY d

Summary of the content on the page No. 17

KEYPAD FUNCTIONS Reset System Trouble? System troubles display and sound at the keypad. Correcting RESET the trouble will clear most indications, however the following error codes will require SYS TRBL Y/N manual reset: E13; E19; E20 and E22. (See SYSTEM TROUBLE ERROR CODES for a description of error codes.) Reset Sensor Watch Failure? (Sensor Watch programmed? !YES !NO). RESET Your system may have been programmed for Sensor Watch, a feature which supervises SENSOR MSG Y/N the motio

Summary of the content on the page No. 18

KEYPAD FUNCTIONS Activate Telephone Test? (Telephone Test programmed? !YES !NO). Sends a ACTIVATE communicator test to the central station. A communication failure will be indicated DIALER TEST Y/N at the keypad by a system trouble “E03-FAIL TO COMM” display. Repeat the test to attempt to correct a communication failure, as any successful communication will clear this display. Delay Arming 1-4 hours. (Not for UL-listed systems.) Your system may be set to arm TO ARM IN 1-4 HRS automatically a

Summary of the content on the page No. 19

KEYPAD FUNCTIONS Activate Program? Activates the Program Mode from Keypad No. 1. Note: This ACTIVATE feature is disabled while armed . (See PROGRAMMING USER CODES) PROGRAM Y/N Activate Download? For installer's use only. If accidentally enabled, press C ACTIVATE DOWNLOAD Y/N to exit. Note: This feature is disabled while armed. Relay Control? (Relay Control programmed? !YES !NO). RELAY Turns ON or OFF one or more programmed Relay Groups. Press Jto turn the CONTROL Y/N dis

Summary of the content on the page No. 20

CENTRAL STATION MONITORING Your alarm specialist may have armed. Any or all of up to 96 This will signal at the keypad as a programmed your system to be different users can each be “ringback” beep. Note: If the ringback monitored by a central station. The identified. If your system reports on signal is not heard, call for service. built-in digital communicator can arming (Closing Report), the central transmit emergency signals and status station will acknowledge arming. reports to the central st


Alternative user manuals
# User manual Category Download
1 Napco Security Technologies F-TPG User manual Home Security System 3
2 Napco Security Technologies GEM-K1CA User manual Home Security System 29
3 Napco Security Technologies EXPRESS XP-600 User manual Home Security System 115
4 Napco Security Technologies GEM-DXRP1 User manual Home Security System 2
5 Napco Security Technologies GEM-Series User manual Home Security System 7
6 Napco Security Technologies Alert 800S User manual Home Security System 5
7 Napco Security Technologies GEMINI GEM-P3200 User manual Home Security System 121
8 Napco Security Technologies GEMINI GEM-P400 User manual Home Security System 14
9 Napco Security Technologies GEM-P1664 User manual Home Security System 101
10 Napco Security Technologies MAGNUM 825 User manual Home Security System 14
11 Napco Security Technologies MA3000 User manual Home Security System 89
12 Napco Security Technologies MAGNUM 825HS User manual Home Security System 2
13 Napco Security Technologies NAPCO EXPRESS XP-600 User manual Home Security System 131
14 Napco Security Technologies 1008 User manual Home Security System 4
15 Napco Security Technologies 1010 User manual Home Security System 0
16 3Com 1000BASE-T-GBIC User manual Home Security System 0
17 Sony BRCSDP12 User manual Home Security System 3
18 3Com TECHD-0000000122 User manual Home Security System 1
19 Sony SSC-M354 User manual Home Security System 3
20 Sony DIGITAL 8 DCR-TRV130E User manual Home Security System 9