FieldServer FS-8707-06 user manual

User manual for the device FieldServer FS-8707-06

Device: FieldServer FS-8707-06
Category: Computer Drive
Manufacturer: FieldServer
Size: 0.13 MB
Added : 8/31/2014
Number of pages: 15
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for FieldServer FS-8707-06. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with FieldServer FS-8707-06.

For your convenience

If looking through the FieldServer FS-8707-06 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual FieldServer FS-8707-06 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual FieldServer FS-8707-06 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
FieldServer FS-8707-06 User manual - Online PDF
Advertisement
« Page 1 of 15 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual FieldServer FS-8707-06 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to FieldServer FS-8707-06. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1



A Sierra Monitor Company

Driver Manual
(Supplement to the FieldServer Instruction Manual)

FS-8707-06
FST OPC Server for FieldServers

APPLICABILITY & EFFECTIVITY
Effective for all systems manufactured after May 1, 2001
Driver Version: 7.16
Document Revision: 7

Summary of the content on the page No. 2

FS-8707-06 FST OPC Server for FieldServers Table of Contents TABLE OF CONTENTS 1. FST OPC SERVER FOR FIELDSERVERS DESCRIPTION ............................................3 1.1. OPC Version Supported ...............................................................................................3 2. DRIVER SCOPE OF SUPPLY.........................................................................................4 2.1. Supplied by FieldServer Technologies for this driver ....................

Summary of the content on the page No. 3

FS-8707-06 FST OPC Server for FieldServers Page 3 of 15 1. FST OPC Server for FieldServers Description This OPC Server (I/O Driver) communicates with the FieldServer. The method of data transfer is called Data Array Access (DAA). The Data Arrays are arrays of typed data memory in the FieldServer. The source of the information in the Data Arrays can be any one of the standard FieldServer I/O Drivers. It is incumbent on the user to configure the ports and the Map Descriptors on

Summary of the content on the page No. 4

FS-8707-06 FST OPC Server for FieldServers Page 4 of 15 2. Driver Scope of Supply 2.1. Supplied by FieldServer Technologies for this driver FieldServer Technologies Description PART # FS-8915-10 UTP cable (7 foot) for Ethernet connection FS-8707-06 Driver Manual rd 2.2. Provided by the Supplier of 3 Party Equipment rd 2.2.1. Required 3 Party Software This OPC Server package must be installed on a Client supplied PC with the following requirements: • Operating Systems: One

Summary of the content on the page No. 5

FS-8707-06 FST OPC Server for FieldServers Page 5 of 15 3. Hardware Connections The FST OPC Server communicates with the FieldServers via standard Ethernet & TCP/IP connections. Please refer to the FieldServer Configuration Manual for instructions on setting up the FieldServer side. Before proceeding to configure the OPC Server we recommend that you have a proper TCP/IP network setup - verify this by PINGing a FieldServer. Refer to the Microsoft documentation for the setup of

Summary of the content on the page No. 6

FS-8707-06 FST OPC Server for FieldServers Page 6 of 15 4. Installing the FST OPC Server for FieldServers From the CD run the file Setup.exe You will be guided through a series of dialogs prompting you for an Installation directory. When asked if you wish to install a Client or Server, “Server” is the default & recommended. Only Select Client If you wish to run the OPC Server on a different machine from the one where the OPC Client (usually a SCADA System) is running. FieldServe

Summary of the content on the page No. 7

FS-8707-06 FST OPC Server for FieldServers Page 7 of 15 5. Quick Start Steps to Implement a simple OPC configuration 1. Configure a FieldServer with a valid IP address. Make sure that at least one Data Array exists. An N1 or N2 connection must be configured with the SMT protocol (SMT is default so the protocol field can be blank). This Nx connection must be the one used to connect to the OPC Server machine. 2. Open a DOS box and “PING” the FieldServer from this machine to che

Summary of the content on the page No. 8

FS-8707-06 FST OPC Server for FieldServers Page 8 of 15 6. Configuring Your OPC Client to use the FST OPC Server for FieldServers OPC Server. The OPC Client refers to the Application Using the data available in the FieldServer. Normally this is a SCADA system or other third party software. From your Client browse the OPC Servers installed on the machine. Select the one named “FieldServer.7.16k”. If you installed the Server on this machine then your Client should find this lis

Summary of the content on the page No. 9

FS-8707-06 FST OPC Server for FieldServers Page 9 of 15 7. Quick Start Steps to Implement a Simple Intellution Fix Configuration 1. Configure a FieldServer with a valid IP address. Make sure that at least one Data Array exists. An N1 or N2 connection must be configured with the SMT protocol (SMT is default so the protocol field can be blank). This Nx connection must be the one used to connect to the OPC Server machine. 2. Open a DOS box and “PING” the FieldServer from this mac

Summary of the content on the page No. 10

FS-8707-06 FST OPC Server for FieldServers Page 10 of 15 11. In the Fix Database Builder add a new block (AI,AO,DI,DO,MDI) and set the I/O Device to “FST” enter I/O addresses in the following format for AI & AR blocks & DI & DR & MDI blocks to bit datatype addresses. :: enter I/O addresses in the following format for DI & DR & MDI blocks to packed bit addresses in Integer datatypes. :::<

Summary of the content on the page No. 11

FS-8707-06 FST OPC Server for FieldServers Page 11 of 15 8. Example Setup 8.1. Sample FieldServer Setup In this example, the low level driver (Modbus) is irrelevant to the operation of the OPC Server, however the user needs to be aware of how field addresses map to Data Array addresses. FieldServer Title, DAA_TEST // Server Side Connections connections adapter, protocol n1, SMT Data_Arrays Data_Array_Name

Summary of the content on the page No. 12

FS-8707-06 FST OPC Server for FieldServers Page 12 of 15 8.2. Example OPC Server Setup FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldServer.com Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: support@fieldServer.com

Summary of the content on the page No. 13

FS-8707-06 FST OPC Server for FieldServers Page 13 of 15 Appendix A. Troubleshooting Appendix A.1. FAQ Q: I cannot “see” the “FieldServer.7.16k” listed as an available data source? A: When Configuring an OPC Client link to the FieldServer OPC, your OPC Client will be browsing for available Servers using the OPC Foundation supplied utility OPCENUM.EXE (Installed with the FST OPC Server for FieldServers) 1. If the Client & Server are on the same machine • Check that OPCEN

Summary of the content on the page No. 14

FS-8707-06 FST OPC Server for FieldServers Page 14 of 15 Appendix A.2. The OPC Server – Limitations- Q&A Q: How many fieldServers can one OPC Server communicate with? A: Unlimited Q: How many Clients can connect to the Server and how many points are possible? A: Unlimited Clients & points, memory usage is about 2k/point/Client e.g.20 Clients with 10000 tags ea = 400MB. Server creates a thread for each Client, default each Client is looping thru 10000 tags every 25 ms looking

Summary of the content on the page No. 15

FS-8707-06 FST OPC Server for FieldServers Page 15 of 15 THIS PAGE INTENTIONALLY LEFT BLANK FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldServer.com Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: support@fieldServer.com


Alternative user manuals
# User manual Category Download
1 FieldServer FS-8700-01 User manual Computer Drive 0
2 FieldServer FS-8700-114 X30 User manual Computer Drive 0
3 FieldServer FS-8700-64 User manual Computer Drive 0
4 FieldServer Carrier DataPort FS-8700-86 User manual Computer Drive 2
5 FieldServer FS-8700-80 User manual Computer Drive 1
6 FieldServer FS-8700-103 User manual Computer Drive 1
7 FieldServer Dart FS-8700-78 User manual Computer Drive 1
8 FieldServer Gamewell FS-8700-83 User manual Computer Drive 2
9 FieldServer Data Aire (DAP) FS-8704-49 User manual Computer Drive 15
10 FieldServer FS-8700-105 User manual Computer Drive 1
11 FieldServer A Sierra Monitor Company X30 User manual Computer Drive 2
12 FieldServer FS-8700-73 User manual Computer Drive 1
13 FieldServer FS-8700-03 DF1 User manual Computer Drive 1
14 FieldServer Gardner Denver FS-8700-60 User manual Computer Drive 11
15 FieldServer Canatal Satchnet Driver FS-8700-59 User manual Computer Drive 3
16 Sony MSH-128S2 User manual Computer Drive 2
17 Sony 2GB Flash Drive USM2GLX User manual Computer Drive 0
18 Sony SAITE1300-F User manual Computer Drive 0
19 Sony CRX - 160E User manual Computer Drive 0
20 Sony 2GN User manual Computer Drive 0