FieldServer Gardner Denver FS-8700-60 user manual

User manual for the device FieldServer Gardner Denver FS-8700-60

Device: FieldServer Gardner Denver FS-8700-60
Category: Computer Drive
Manufacturer: FieldServer
Size: 0.12 MB
Added : 6/13/2013
Number of pages: 13
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for FieldServer Gardner Denver FS-8700-60. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with FieldServer Gardner Denver FS-8700-60.

For your convenience

If looking through the FieldServer Gardner Denver FS-8700-60 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual FieldServer Gardner Denver FS-8700-60 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual FieldServer Gardner Denver FS-8700-60 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
FieldServer Gardner Denver FS-8700-60 User manual - Online PDF
Advertisement
« Page 1 of 13 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual FieldServer Gardner Denver FS-8700-60 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to FieldServer Gardner Denver FS-8700-60. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1



A Sierra Monitor Company

Driver Manual
(Supplement to the FieldServer Instruction Manual)

FS-8700-60 Gardner Denver Auto Sentry
ES/RS2000

APPLICABILITY & EFFECTIVITY
Effective for all systems manufactured after May 1, 2001

Summary of the content on the page No. 2

FS-8700-60 Gardner Denver Manual Table of Contents TABLE OF CONTENTS 1. Gardner Denver Auto Sentry ES/RS2000 Description....................................... 1 2. Driver Scope of Supply........................................................................................ 2 1.01 Supplied by FieldServer Technologies for this driver ....................................... 2 rd 1.02 Provided by the Supplier of 3 Party Equipment.............................................. 2 rd 2.1

Summary of the content on the page No. 3

FS-8700-60 Gardner Denver Manual Page 1 of 11 1. Gardner Denver Auto Sentry ES/RS2000 Description The Gardner Denver Auto Sentry ES/RS2000 driver allows the FieldServer to transfer data from devices over either RS-232 or RS-485 using Gardner Denver Auto Sentry ES/RS2000 protocol. The driver can be configured to communicate with ES Controllers with software versions V2.0X, V2.1X and RS2000 Controllers with software versions V4.0X The client driver implements the following fun

Summary of the content on the page No. 4

FS-8700-60 Gardner Denver Manual Page 2 of 11 2. Driver Scope of Supply 1.01 Supplied by FieldServer Technologies for this driver FieldServer Technologies Description PART # FS-8915-10 UTP cable (7 foot) for RS-232 use FS-8917-03 RJ45 to DB9M connector adapter FS-8700-60 Driver Manual rd 1.02 Provided by the Supplier of 3 Party Equipment rd 2.1.1. Required 3 Party Hardware Part # Description - ES/RS2000 controller rd 2.1.2. Required 3 Party Software None. rd 2.1.3. R

Summary of the content on the page No. 5

FS-8700-60 Gardner Denver Manual Page 3 of 11 3. Hardware Connections The FieldServer is connected to the ES/RS2000 Controller as shown in the connection drawing below: Configure the ES/RS2000 Controller according to manufacturer’s instructions. 1.03 Hardware Connection Tips / Hints If inter-controller communications are set up for the controller, connect to the RS-232 port only. If inter-controller communications are not used, connect to either the RS- 232 or RS-485 po

Summary of the content on the page No. 6

FS-8700-60 Gardner Denver Manual Page 4 of 11 4. Configuring the FieldServer as a Gardner Denver Auto Sentry ES/RS2000 Client For a detailed discussion on FieldServer configuration, please refer to the FieldServer Configuration Manual. The information that follows describes how to expand upon the factory defaults provided in the configuration files included with the FieldServer (See “.csv” sample files provided with the FieldServer). This section documents and describes the parame

Summary of the content on the page No. 7

FS-8700-60 Gardner Denver Manual Page 5 of 11 1.05 Client Side Connection Descriptions Section Title Connections Column Title Function Legal Values Specify which port the device 1 Port is connected to the P1-P8, R1-R2 FieldServer Protocol Specify protocol used Gardner_Denver Baud* Specify baud rate 1200, 9600 (match to Controller) Parity* Specify parity None Data_Bits* Specify data bits 7 Stop_Bits* Specify stop bits 1 Specify hardware Handshaking* None handshaking

Summary of the content on the page No. 8

FS-8700-60 Gardner Denver Manual Page 6 of 11 1.06 Client Side Node Descriptors Section Title Nodes Column Title Function Legal Values Up to 32 alphanumeric Node_Name Provide name for node characters Unit number connected to an Node_ID 1-8 ES/RS2000 controller Protocol Specify protocol used Gardner_Denver Specify which port the device is 1 Connection P1-P8, R1-R2 connected to the FieldServer Sets the protocol to be used for ES V2.0X Node_Type* different Controller so

Summary of the content on the page No. 9

FS-8700-60 Gardner Denver Manual Page 7 of 11 4.1.2. Driver Related Map Descriptor Parameters Column Function Legal Values Title Name of Node to fetch data One of the node names specified Node_Name from in “Client Node Descriptor” above Service_Data, Operating_Mode, Gar_cmd Data poll commands Operating_Data Available with Service_Data: All, Advisories, Shutdown_codes, Hourmeter_shutdown, Hourmeter_total, Hourmeter_loaded, Hourmeter_temp, Data fields in a data poll Hour

Summary of the content on the page No. 10

FS-8700-60 Gardner Denver Manual Page 8 of 11 4.1.4. Map Descriptor Example 1 – Polling all available Controller Data Map_Descriptor_Name, Data_Array_Name, Data_Array_Offset, Function, Node_Name, Gar_cmd, Gar_data, Scan_Interval GD_MBA1, DA_Service_Data, 0, RDBC, Node_1, Service_Data, All, 1.0s GD_MBA2, DA_Oper_Mode, 0, RDBC, Node_1, Operating_Mode, All, 1.0s GD_MBA3, DA_Oper_Data, 0, RDBC, Node_1, Operating_Data, All, 1.0s Note the active Read Block Continuous

Summary of the content on the page No. 11

FS-8700-60 Gardner Denver Manual Page 9 of 11 4 4 Motor current amps 4.1.5. Map Descriptor Example 2 - Polling only specific data items Map_Descriptor_Name, Data_Array_Name, Data_Array_Offset, Function, Node_Name, Gar_cmd, Gar_data, Scan_Interval GD_MBA1, DA_Hourmeter, 0, RDBC, Node_1, Service_Data, Hourmeter_total, 1.0s GD_MBA2, DA_Oper_Mode, 0, RDBC, Node_1, Operating_Mode, Oper_mode, 1.0s GD_MBA3, DA_Motor_Amps, 0, RDBC, Node_1, Operating_Data, Motor_current, 1.0s N

Summary of the content on the page No. 12

FS-8700-60 Gardner Denver Manual Page 10 of 11 Appendix 1. Advanced Topics Appendix 1.1. Can I use only Passive Client mapdescs ? No. A passive client map descriptor must be used after an active RDBC map descriptor. The driver uses the active map descriptors to poll the Controller and then searches for Passive Client map descriptors with matching Node_Name and Gar_Cmd fields. It then stores the data items as specified by the Gar_data field from the data collected by the preceding

Summary of the content on the page No. 13

FS-8700-60 Gardner Denver Manual Page 11 of 11 Appendix 2. Revision History Driver Doc. Date Resp Format Comment Ver. Rev. 9/2/02 JDM 1.00a 1 Applying new template. 4/12/04 DR DR 1.02b 2 Updated 7/12/04 DR DR 1.03a 3 Updated connection diagram Redrew connection diagram. 7/16/04 Meg Meg 1.03a 4 Reformatted document. Replaced connection diagram with 8/24/04 Meg Meg 1.03a 5 original created by Deon. 12/29/04 JD 1.03a 6 Releasing FieldServer Technologies 1991 Tarob Court


Alternative user manuals
# User manual Category Download
1 FieldServer FS-8700-01 User manual Computer Drive 0
2 FieldServer FS-8700-114 X30 User manual Computer Drive 0
3 FieldServer FS-8700-64 User manual Computer Drive 0
4 FieldServer Carrier DataPort FS-8700-86 User manual Computer Drive 2
5 FieldServer FS-8700-80 User manual Computer Drive 1
6 FieldServer FS-8700-103 User manual Computer Drive 1
7 FieldServer Dart FS-8700-78 User manual Computer Drive 1
8 FieldServer Gamewell FS-8700-83 User manual Computer Drive 2
9 FieldServer Data Aire (DAP) FS-8704-49 User manual Computer Drive 15
10 FieldServer FS-8700-105 User manual Computer Drive 1
11 FieldServer A Sierra Monitor Company X30 User manual Computer Drive 2
12 FieldServer FS-8700-73 User manual Computer Drive 1
13 FieldServer FS-8700-03 DF1 User manual Computer Drive 1
14 FieldServer Canatal Satchnet Driver FS-8700-59 User manual Computer Drive 3
15 FieldServer ControlNet FS-8700-104 User manual Computer Drive 1
16 Sony MSH-128S2 User manual Computer Drive 2
17 Sony 2GB Flash Drive USM2GLX User manual Computer Drive 0
18 Sony SAITE1300-F User manual Computer Drive 0
19 Sony CRX - 160E User manual Computer Drive 0
20 Sony 2GN User manual Computer Drive 0