Summary of the content on the page No. 1 
                    
                        -  
     
         A Sierra Monitor Company 
 
Driver Manual  
(Supplement to the FieldServer Instruction Manual) 
 
FS-8700-41 Simplex Time Recorder 
Company - 4100 Computer Port Protocol 
 
APPLICABILITY & EFFECTIVITY 
Effective for all systems manufactured after May 1, 2001 
Driver Version: 1.07 
Document Revision:  8 
                                                                                                                                                                                
                    
                    Summary of the content on the page No. 2 
                    
                        FS-8700-41 Simplex Driver Manual      Table of Contents    TABLE OF CONTENTS  1. Simplex Time Recorder Company - 4100 Computer Port Protocol ............................. 4  1.1. Supported Panel Types............................................................................................... 4  1.2. Simplex Panel Firmware Revision vs. Supported Functionality ................................... 4  2. Driver Scope of Supply .......................................................................
                    
                    Summary of the content on the page No. 3 
                    
                        FS-8700-41 Simplex Driver Manual      Table of Contents    Appendix A.11. Advanced Map Descriptor Example 2. - Read Panel Time.........................33  Appendix A.12. Advanced Map Descriptor Example 3 - Write Panel Time ..........................34  Appendix A.13. Advanced Map Descriptor Example 4 - Panel Revision Information...........34  Appendix A.14. Advanced Map Descriptor Example 5 - AckAll ...........................................35  Appendix A.15. Advanced Map Descriptor Example 6 -
                    
                    Summary of the content on the page No. 4 
                    
                        FS-8700-41 Simplex 4100 Driver Manual      Page 4 of 58  1. Simplex Time Recorder Company - 4100 Computer Port Protocol  The Simplex Time Recorder Company - 4100 Computer Port Protocol driver allows the  FieldServer to transfer data to and from devices over either RS-232 or RS-485 using Simplex  Time Recorder Company - 4100 Computer Port Protocol.      This driver is designed to connect to a Simplex 4100 panel equipped to support the “4100  Computer Port Protocol” as defined in Simplex’s documen
                    
                    Summary of the content on the page No. 5 
                    
                        FS-8700-41 Simplex 4100 Driver Manual      Page 5 of 58  2. Driver Scope of Supply  2.1. Supplied by FieldServer Technologies for this driver  FieldServer Technologies  Description  PART #  FS-8917-16 Ethernet Cable with pigtail (4020 and 4100 Panels)  Ethernet cable with 25 pin male connector. (4100u  FS-8917-07  Panels)  SPA59132 RS-485 connection adapter  FS-8700-41 Driver Manual.    rd 2.2. Provided by Supplier of 3 Party Equipment  To enable the 4100 Protocol, the 4100 system, supplied by t
                    
                    Summary of the content on the page No. 6 
                    
                        FS-8700-41 Simplex 4100 Driver Manual      Page 6 of 58  3. Hardware Connections  The FieldServer is connected to the Simplex Device’s RS-232 port of device type  "COMPUTER", the following port attributes may be configured specifically for that particular  port:     Ensure that these settings correspond to the settings described in section 4 of this document.    Sim4100 Panel  Setting Default  Options  Baud Rate 9600 75, 110, 134.5, 300, 600, 1200, 1800, 2000, 2400, 4800, 9600, 19200  1 Parity E
                    
                    Summary of the content on the page No. 7 
                    
                        FS-8700-41 Simplex 4100 Driver Manual      Page 7 of 58  3.1. Connection to a Simplex 4020 Panel  Communication Board  Chip 4100 RS2120    Card 4020/RS-232/2120 modem ready  assembly.     Terminal Block Markings  Port A =1-5, Port B=6-10.      1=+com(xmt).   2=+com(rts),  3=-com(rcv),   4=-com(cts),   5=gnd,   6=xmt,   7=rts,  8=rcv,  9=cts,  10=gnd,   FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA  Web:www.fieldserver.com  Tel: (408) 262-2299   Fax: (408) 262-2296   To
                    
                    Summary of the content on the page No. 8 
                    
                        FS-8700-41 Simplex 4100 Driver Manual      Page 8 of 58  Serial Connection            FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA  Web:www.fieldserver.com  Tel: (408) 262-2299   Fax: (408) 262-2296   Toll_Free: 888-509-1970   email: support@fieldserver.com                                                                                                                                                                                                                       
                    
                    Summary of the content on the page No. 9 
                    
                        FS-8700-41 Simplex 4100 Driver Manual      Page 9 of 58  3.2. Connection to a Simplex 4100 Panel  WIRE LIST FS-X40 FROM SIMPLEX 4100  FUNCTION PANEL RX RJ45-01 XMIT TX RJ45-08 RCV GND RJ45-04 GND SIMPLEX 100  PANEL PORT B  CONNECTION GND CTS RCV RTS FS-8917-16 XMIT P1-P8 P1 P2 P3 P4 P5 P6 P7 P8 R1  R2 N1  N2   RS485 10 Base T RS232 ETHERNET P1 P2 P3 P4 P5 P6 P7 P8 R1 R2 Net 1 Net 2 Rx Tx Rx Tx Rx Tx Rx Tx Rx Tx Rx Tx Rx Tx Rx Tx Rx Tx Rx Tx Tx Rx Con Tx Rx Con (408)-262-2299 SIMPLEX 4100 CONNECT
                    
                    Summary of the content on the page No. 10 
                    
                        FS-8700-41 Simplex 4100 Driver Manual      Page 10 of 58  3.3. Connection to a Simplex 4100U Panel  Front of 4100U Panel Port A  Port B      Pin 3 - Blue  Pin 7 - Green  Pin 2 - White        FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA  Web:www.fieldserver.com  Tel: (408) 262-2299   Fax: (408) 262-2296   Toll_Free: 888-509-1970   email: support@fieldserver.com                                                                                                              
                    
                    Summary of the content on the page No. 11 
                    
                        FS-8700-41 Simplex 4100 Driver Manual      Page 11 of 58    FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA  Web:www.fieldserver.com  Tel: (408) 262-2299   Fax: (408) 262-2296   Toll_Free: 888-509-1970   email: support@fieldserver.com                                                                                                                                                                                                                                                 
                    
                    Summary of the content on the page No. 12 
                    
                        FS-8700-41 Simplex 4100 Driver Manual      Page 12 of 58  4. Configuring the FieldServer as a Simplex Time Recorder Company - 4100  Computer Port Protocol Client  For a detailed discussion on FieldServer configuration, please refer to the relevant instruction  manual.  The information that follows describes how to expand upon the factory defaults  provided in the configuration files included with the FieldServer (See “.csv” files provided with  the FieldServer).    This section documents and des
                    
                    Summary of the content on the page No. 13 
                    
                        FS-8700-41 Simplex 4100 Driver Manual      Page 13 of 58  4.2. Client Side Connection Descriptions  Section Title  Connections  Column Title Function Legal Values  Specify which port the device is connected  3 Port P1-P8, R1-R2  to the FieldServer  110 – 115200, standard baud  Baud* Specify baud rate  rates only.    Even, Odd, None, Mark,  Parity* Specify parity  Space  Data_Bits*  Specify data bits 7, 8  Stop_Bits*  Specify stop bits 1  Protocol  Specify protocol used sim4100   Handshaking* Spe
                    
                    Summary of the content on the page No. 14 
                    
                        FS-8700-41 Simplex 4100 Driver Manual      Page 14 of 58  Example    //    Client Side Nodes       Nodes     Node_Name,     PLC_Type, Protocol, Connection  Device1,            4100U, Sim4100, P8    4.4. Client Side Driver Tables  A driver table is used to extend a table of values/attributes that have been hard coded into  the driver.  It is possible to extend the tables using CSV file parameters.    Additional information on the use of these tables may be found in Appendix A.8     4.4.1. SHOW Re
                    
                    Summary of the content on the page No. 15 
                    
                        FS-8700-41 Simplex 4100 Driver Manual      Page 15 of 58  4.4.2. SHOW Response Attribute States Driver Table  Column Title Function Legal Values  The protocol must be  Protocol specified on each row of Sim4100  a driver table.  Use this parameter to Define a state word such as  extend this list of ‘Normal’ and associate a  sim4100_Attr_State_Name  predefined attribute value using the ‘value’  states. parameter.  This parameter is the  sim4100_Attr_State_Value value to be associated May not be ze
                    
                    Summary of the content on the page No. 16 
                    
                        FS-8700-41 Simplex 4100 Driver Manual      Page 16 of 58  4.5.4. Protocol (Simplex Device) Specific Parameters  Column Title Function Legal Values  Further notes on  these keywords  are provided in  Appendix A    Ackall, Setd,  A keyword which controls the function being  Disable, Restart,  sim4100_func performed or the type of data being polled /  Clistall, Clist,  written.  Time, Ctime,  Ack,  Xpoint, Seta,  Super, Show,  Earths, Value,  ClearAll  The Simplex Time Recorder Company - 4100 Compu
                    
                    Summary of the content on the page No. 17 
                    
                        FS-8700-41 Simplex 4100 Driver Manual      Page 17 of 58  4.5.5. Map Descriptor Example 1. - Read Point Status  This Map Descriptor can be used to poll for the status of a particular point.  When the response is obtained the driver sets the value  of one Data Array element to a number indicating the point’s status.  The values are described in Appendix A.4.  You need one such  Map Descriptor for every point whose status you wish to poll. Notes in Appendix A.13 provide more information    Map_Des
                    
                    Summary of the content on the page No. 18 
                    
                        FS-8700-41 Simplex 4100 Driver Manual      Page 18 of 58  4.5.6. Map Descriptor Example 2. - Use unsolicited messages from the Panel to determine point  status  This Map Descriptor can be used to store point status data when the FieldServer receives an unsolicited message from the Panel  containing point status information (Xpoint messages).  The panel sends an Xpoint message each time a point’s status changes to  any non-normal state.  Using these Map Descriptors will ensure that the FieldServe
                    
                    Summary of the content on the page No. 19 
                    
                        FS-8700-41 Simplex 4100 Driver Manual      Page 19 of 58  5. Configuring the FieldServer as a Simplex Time Recorder Company - 4100  Computer Port Protocol Server  The driver contains some server side functionality which has been developed to meet  FieldServer’s continuous quality assurance efforts.  However, the server side functions are not  documented or supported for customer use. If you have a strong requirement for this  functionality then please contact the Sales and Marketing group of Fie
                    
                    Summary of the content on the page No. 20 
                    
                        FS-8700-41 Simplex 4100 Driver Manual      Page 20 of 58  Appendix A. Advanced Topics  Appendix A.1. Hardware Handshaking  The driver does not support the Simplex RTS/CTS handshaking model.  Therefore deselect  the HSHAKE terminal flag or connect CTS to RTS with a jumper on the 4100 side.    Appendix A.2. Simplex Address Formatting – Specific Keywords   The Simplex Time Recorder Company - 4100 Computer Port Protocol only uses the  standard 4100 address format of --.  Symb