FieldServer FS-8700-12 user manual

User manual for the device FieldServer FS-8700-12

Device: FieldServer FS-8700-12
Category: Computer Drive
Manufacturer: FieldServer
Size: 0.06 MB
Added : 6/13/2013
Number of pages: 14
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for FieldServer FS-8700-12. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with FieldServer FS-8700-12.

For your convenience

If looking through the FieldServer FS-8700-12 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual FieldServer FS-8700-12 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual FieldServer FS-8700-12 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
FieldServer FS-8700-12 User manual - Online PDF
Advertisement
« Page 1 of 14 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual FieldServer FS-8700-12 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to FieldServer FS-8700-12. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1



A Sierra Monitor Company

Driver Manual
(Supplement to the FieldServer Instruction Manual)

FS-8700-12 AB DH+

APPLICABILITY & EFFECTIVITY
Effective for all systems manufactured after May 1, 2001

Summary of the content on the page No. 2

FS-8700-12_DH+ Manual Page 2 of 14 TABLE OF CONTENTS 1. Allen Bradley DH+ Description ......................................................................................3 2. Driver Scope of Supply...................................................................................................4 2.1. Supplied by FieldServer Technologies for this Driver ...................................................4 rd 2.2. Provided by the supplier of 3 Party Equipment .................

Summary of the content on the page No. 3

FS-8700-12_DH+ Manual Page 3 of 14 1. Allen Bradley DH+ Description The DH+ driver allows the FieldServer to transfer data to and from devices using DH+ protocol. The Communications Adapter card is included with the FieldServer. The FieldServer can emulate either a Server or Client. The information that follows describes how to expand upon the factory defaults provided in the configuration files included with the FieldServer. FieldServer Technologies 1991 Tarob Court Mi

Summary of the content on the page No. 4

FS-8700-12_DH+ Manual Page 4 of 14 2. Driver Scope of Supply 2.1. Supplied by FieldServer Technologies for this Driver SMC PART # DESCRIPTION FS-SPA23027 DH+ cable rd 2.2. Provided by the supplier of 3 Party Equipment 2.2.1. Hardware PART # DESCRIPTION 1 AB DH+ compatible PLC, e.g. SLC5/03, PLC 5/40, etc 2 DH+ Client, e.g. RSView, Wonderware, Intellution FIX, GE Cimplicity, etc. 1 If FieldServer used as Allen Bradle

Summary of the content on the page No. 5

FS-8700-12_DH+ Manual Page 5 of 14 3. Hardware Connections Configure the PLC according to manufacturer’s instructions and configure checksum to use BCC checksum, not CRC. FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: support@fieldserver.com

Summary of the content on the page No. 6

FS-8700-12_DH+ Manual Page 6 of 14 4. Configuring theFieldServer as a DH+ Client For a detailed discussion on FieldServer configuration, please refer to the FieldServer Configuration Manual. The information that follows describes how to expand upon the factory defaults provided in the configuration files included with the FieldServer (See “.csv” sample files provided with the FS). This section documents and describes the parameters necessary for configuring the FieldServer

Summary of the content on the page No. 7

FS-8700-12_DH+ Manual Page 7 of 14 4.2. Client Side Connection Descriptors Section Title Connections Column Title Function Legal Values Port Port name DH+ Protocol Specify protocol used AB_DH+ Example // Client Side Connections Connections Port, Protocol DH+, AB_DH+ 4.3. Client Side Node Descriptors Section Title Nodes Column Title Function Legal Values Up to 32 alphanumeric Node_Name Provide name for node characters Node ID of physical server node N

Summary of the content on the page No. 8

FS-8700-12_DH+ Manual Page 8 of 14 4.4. Client Side Map Descriptors Section Title Map_Descriptors Column Title Function Legal Values Name of this Map Up to 32 alphanumeric Map_Descriptor_Name Descriptor characters Name of Data Array where One of the Data Array Data_Array_Name data is to be stored in the names from “Data Array” FieldServer section above 0 to maximum specified Starting location in Data Data_Array_Offset in “Data Array” section Array above Function of C

Summary of the content on the page No. 9

FS-8700-12_DH+ Manual Page 9 of 14 4.4.1. Map Descriptor Example // Client Side Map Descriptors Map_Descriptors Map_Descriptor_Name, Data_Array_Name, Data_Array_Offset, Function Node_Name File_Type, File_Number, Address, Length Scan_Interval CMD_AI_01, DA_AI_01, 0, Rdbc PLC 1 N 10 0 16 1.0s CMD_AO_01, DA_AO_01, 0, Rdbc PLC 1 N 11 0 16 1.0s Map_Descriptors Map_Descriptor_Name, Data_Array_Name, Data_Array_Offset, Function Node_Name Fi

Summary of the content on the page No. 10

FS-8700-12_DH+ Manual Page 10 of 14 5. FieldServer as a DH+ Server 5.1. Server Side Connection Descriptors Section Title Connections Column Title Function Legal Values Port Port name DH+ Protocol Specify protocol used AB_DH+ Example // Server Side Connections Connections Port, Protocol DH+, AB_DH+ 5.2. Server Side Node Descriptors Section Title Nodes Column Title Function Legal Values Up to 32 alphanumeric Node_Name Provide name for node characters No

Summary of the content on the page No. 11

FS-8700-12_DH+ Manual Page 11 of 14 5.3. Server Side Map Descriptors Section Title Map_Descriptors Column Title Function Legal Values Name of this Map Up to 32 alphanumeric Map_Descriptor_Name Descriptor characters Name of Data Array where One of the Data Array Data_Array_Name data is to be stored in the names from “Data Array” FieldServer section above 0 to maximum specified Starting location in Data Data_Array_Offset in “Data Array” section Array above Function of

Summary of the content on the page No. 12

FS-8700-12_DH+ Manual Page 12 of 14 Map Descriptor Example // Server Side Map Descriptors Map_Descriptors Map_Descriptor_Name, Data_Array_Name, Data_Array_Offset, Function, Node_Name, File_Type, File_Number, Address, Length, Data_Array_Low_Scale, Data_Array_High_Scale, Node_Low_Scale, Node_High_Scale SMD_AI_01, DA_AI_01, 0, Server, DHP_Srv_11, N, 10, 0, 200, 0, 100, 0, 100 SMD_AO_01, DA_AO_01, 0, Server, DHP_Srv_11, N, 11, 0, 200, 0, 100, 0, 100 Map_Des

Summary of the content on the page No. 13

FS-8700-12_DH+ Manual Page 13 of 14 6. Driver Notes 6.1. Continuous Map Descriptors RS View has been known to crash if it tries to read a server mapping that is discontinuous. e.g. Server map 1: N21: 0-31 Server map 2: N21: 32-100 This will panic the FieldServer and crash RS view as the DH+ will attempt to map N21: 0-100 If set up as: Server Map 1: N21: 0-100 No problems are experienced 6.2. Checksum When selecting checksum options for DH+ devices communicating

Summary of the content on the page No. 14

FS-8700-12_DH+ Manual Page 14 of 14 7. Revision History Driver Document Date Resp Comment Version Revision 11/28/03 1 MF Updated formatting 2/18/04 2 JD Releasing


Alternative user manuals
# User manual Category Download
1 FieldServer FS-8700-01 User manual Computer Drive 0
2 FieldServer FS-8700-114 X30 User manual Computer Drive 0
3 FieldServer FS-8700-64 User manual Computer Drive 0
4 FieldServer Carrier DataPort FS-8700-86 User manual Computer Drive 2
5 FieldServer FS-8700-80 User manual Computer Drive 1
6 FieldServer FS-8700-103 User manual Computer Drive 1
7 FieldServer Dart FS-8700-78 User manual Computer Drive 1
8 FieldServer Gamewell FS-8700-83 User manual Computer Drive 2
9 FieldServer Data Aire (DAP) FS-8704-49 User manual Computer Drive 15
10 FieldServer FS-8700-105 User manual Computer Drive 1
11 FieldServer A Sierra Monitor Company X30 User manual Computer Drive 2
12 FieldServer FS-8700-73 User manual Computer Drive 1
13 FieldServer FS-8700-03 DF1 User manual Computer Drive 1
14 FieldServer Gardner Denver FS-8700-60 User manual Computer Drive 11
15 FieldServer Canatal Satchnet Driver FS-8700-59 User manual Computer Drive 3
16 Sony MSH-128S2 User manual Computer Drive 2
17 Sony 2GB Flash Drive USM2GLX User manual Computer Drive 0
18 Sony SAITE1300-F User manual Computer Drive 0
19 Sony CRX - 160E User manual Computer Drive 0
20 Sony 2GN User manual Computer Drive 0