Speco Technologies KBD-927 user manual

User manual for the device Speco Technologies KBD-927

Device: Speco Technologies KBD-927
Category: Mouse
Manufacturer: Speco Technologies
Size: 3.78 MB
Added : 4/19/2014
Number of pages: 33
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Speco Technologies KBD-927. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Speco Technologies KBD-927.

For your convenience

If looking through the Speco Technologies KBD-927 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Speco Technologies KBD-927 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Speco Technologies KBD-927 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Speco Technologies KBD-927 User manual - Online PDF
Advertisement
« Page 1 of 33 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Speco Technologies KBD-927 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Speco Technologies KBD-927. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1



SPECO TECHNOLOGIES KEYBOARD CONTROLLER

KBD-927



Instruction Manual





























L








Please read this manual thoroughly before use and keep it handy for future reference.
Rev.040130

Summary of the content on the page No. 2

WARNING AND CAUTION WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE. DO NOT INSERT ANY METALLIC OBJECTS THROUGH THE VENTILATION GRILLS OR OTHER OPENINGS ON THE EQUIPMENT. CAUTION EXPLANATION OF GRAPHICAL SYMBOLS The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated "dangerous voltage" within the pr

Summary of the content on the page No. 3

FCC COMPLIANCE STATEMENT FCC INFORMATION: THIS EQUIPMENT HAS BEEN TESTED AND FOUND TO COMPLY WITH THE LIMITS FOR A CLASS A DIGITAL DEVICE, PURSUANT TO PART 15 OF THE FCC RULES. THESE LIMITS ARE DESIGNED TO PROVIDE REASONABLE PROTECTION AGAINST HARMFUL INTERFERENCE WHEN THE EQUIPMENT IS OPERATED IN A COMMERCIAL ENVIRONMENT. THIS EQUIPMENT GENERATES, USES, AND CAN RADIATE RADIO FREQUENCY ENERGY AND IF NOT INSTALLED AND USED IN ACCORDANCE WITH THE INSTRUCTION MANUAL, MAY

Summary of the content on the page No. 4

IMPORTANT SAFEGUARDS 1. READ INSTRUCTIONS -- All the safety and operating 10. POWER CORDS -- Do not allow anything to rest on the instructions should be read before the appliance is operated. power cord. Do not locate video monitor or equipment where the cord will be abused by persons walking on it. 2. RETAIN INSTRUCTIONS -- The safety and operating instructions should be retained for future reference. 11. HEED WARNINGS -- Follow all instructions marked on the v

Summary of the content on the page No. 5

Table of Contents Chapter 1.0 INTRODUCTION 1.1 Features 1.2 Unpacking Chapter 2.0 INSTALLATION 2.1 Connection Diagram 2.2 Dip Switch Setting 2.3 Keyboard Setup 2.4 Install with ADR series 2.5 Install with SDR series 2.6 Install with IDR series Chapter 3.0 OPERATION 3.1 Multiplexer Control 3.2 Keyboard Lock/Unlock 3.2 Summary of Keyboard Control Appendix A Trouble Shooting Appendix B SPECIFICATION 5

Summary of the content on the page No. 6

Chapter 1 INTRODUCITON 1.1 Features This keyboard controller is capable to control 32 FastraxII dome cameras and remote control functions for variety of external switching devices like Multiplexer(max 255), Digital Video Recorder(max 99) etc… The keyboard controller features: • The capability of control a camera’s panning and tilting movement with variable speed from 0.5 °/sec to 90 °/sec as well as its zoom, focus, and iris command. Normal speed is inversely proportional to the cur

Summary of the content on the page No. 7

1.2 Unpacking Unpack the equipment and make sure all listed items are included in the box. Contents of Keyboard box Keyboard controller ------------------------------- 1 Junction box --------------------------------------- 1 3m cable -------------------------------------------- 2 M4 Self tapping screws ------------------------- 4 Instruction manual --------------------------------- 1 12VDC SMPS -------------------------------------- 1 7

Summary of the content on the page No. 8

Chapter 2 INSTALLATION 2.1 Connection Diagram 2.1.1 Basic Installation Diagram POWER AC 24V AWG # 24 SIREN POWER AC 24V RS-485 HALF DUPLEX MODE : TX+,TX- LIGHT ALARM OUTPUT SENSOR UP TO 4 ALARM INPUT UP TO 8 ALARM INPUT ALARM INPUT 5~8 1~4 BNC ALARM OUTPUT ALARM OUTPUT 1~2 3~4 (RS-422) MONITOR RS-422 SIMPLEX MODE : TX+,TX- DUPLEX MODE : TX+,TX-,RX+,RX- BNC Figure 2 – Basic installation diagram 8 AC+ AC- FGND (RX+) (RX+) (RX-) (RX-) DOME1 + RX+(TX+) RX+(TX+) RS-485 RX-(TX-) RX-(TX-) DO

Summary of the content on the page No. 9

2.1.2 Single Multiplexer POWER POWER POWER AC 24V AC 24V AC 24V AWG # 24 (RS-422) BNC SPOT MONITOR MAIN MONITOR BNC BNC MULTIPLEXER RS-485(+) PIN No.4 RS-485(-) PIN No.5 Figure 3 – Single Multiplexer 9 AC+ AC- FGND (RX+) (RX+) (RX-) (RX-) RX+(TX+) RX+(TX+) RS-485 RX-(TX-) RX-(TX-) GND AC- AC+ NO4 NO2 NC4 NC2 COM4 COM2 NO3 NO1 NC3 NC1 COM3 COM1 GND GND AL8 AL4 AL7 AL3 GND GND AL2 AL6 AL5 AL1

Summary of the content on the page No. 10

2.1.3 Single User with Two Multiplexer POWER POWER POWER AC 24V AC 24V AC 24V AWG # 24 (RS-422) BNC 1ST MAIN MONITOR SPOT MONITOR 2ND MAIN MONITOR BNC BNC BNC 1ST MULTIPLEXER 2ND MULTIPLEXER RS-485(+) PIN No.4 RS-485(-) PIN No.5 Spot output of the first multiplexer to be th connected to 16 input of the second multiplexer. nd And first spot output of the 2 multiplexer to be connected to the spot monitor. You will see the picture of the selected camera (1~31) on spot monitor by selecting

Summary of the content on the page No. 11

2.1.4 Two Multiplexer with Slave Keyboard Controller POWER POWER POWER AC 24V AC 24V AC 24V AWG # 24 (RS-422) BNC SPOT MONITOR SPOT MONITOR 1ST MAIN MONITOR FOR SLAVE K/B FOR MASTER K/B 2ND MAIN MONITOR BNC BNC BNC 1ST MULTIPLEXER 2ND MULTIPLEXER RS-485(+) PIN No.4 RS-485(-) PIN No.5 th Spot output 1 of the first multiplexer to be connected to 16 input of the second multiplexer. th th nd th n: User, Spot out of n to be connected to (15-n) camera input of the 2 multiplexer. n spot nd

Summary of the content on the page No. 12

2.2 Termination & Dip Switch Setting The first and last devices in an installation (dome and keyboard controller) must have the data line terminated by setting the DIP switch. Without proper termination, there is potential for control signal errors. Total length of the cable for communication should not exceed 1 mile. Refer to Figure 7 for setting the dome camera and keyboard controller termination. Cable for communication More than two branches require repeater (HID2404SR) which

Summary of the content on the page No. 13

Sub- Multi- DOME controll plexer Termination Controller er 1 2 3 4 5 6 7 8 ON ON ON ON SLAVE ON Factory reserved Use OFF OFF OFF OFF MASTER OFF Table 1 - S1 Switch Setting 2.3 Multiplexer Control Duplex setup: NOTE: Multiplexers require a new ROM version to be controlled by the keyboard controller. The new multiplexer ROM accepts control instructions from the keyboard controller. If your multiplexer’s serial number is M104xxxx or higher, then it is ready to accept con

Summary of the content on the page No. 14

Unit address: 001 ~ 128 Protocol: B1 2.4 Keyboard Setup User need to setup network, passwords and special functions such as Uploading and Downloading programmed data from the dome cameras. To enter the Keyboard menu, press Ctrl + Menu. You will see the following menu. Joystick Up/Down scrolls menu items, push the stick to Right to enter the sub-menu. Configuration Network Data Bank Alarm Exit Configuration - Key Beep : ON - enable key beep sound, OFF - Disable beep s

Summary of the content on the page No. 15

- Com Ports Select the device to be connected on selected port. Dome : None/Dome … MUX : None/DUPLEX/TRIPLEX/AUX IN/AUX I/O… DVR485 : None/ADR/SDR/IDR/AUX IN/AUX I/O… DVR232 : None/ADR/SDR/IDR/AUX IN/AUX I/O… Save and Exit Save the programmed data and return to the previous Menu (Exit without saving if you press ESC key) Note) AUX IN : auxiliary signal input ( simplex mode)

Summary of the content on the page No. 16

AC + AC - AC + AC - FG ND (R x+ ) (R x- ) R x+( Tx+) Tx + R x-( Tx-) Tx - GND GND FASTRAX-2L Vxxx Slave ID = 1 ← Current Device ID = 1 Input Password : xxxx ← Default setting is 9999 for administrator 1111 for user CAM:000 3. Press Ctrl + Menu. Set the Slave ID to 01 4. Set Slave Node to “B” in case that master keyboard model is KBD-927(N : NTSC,P : PAL) Slave ID = 1 Slave Node : A/B ← A : KBD-927 RS485 Protocol Half duplex mode Tx-,Tx+ NO4 NO2 NC 4 NC 2 COM4 COM

Summary of the content on the page No. 17

A. Switch the keyboard controller ON B. Input password (Factory setting is 9999) C. Open the menu of the keyboard controller by pressing Ctrl + Main Key. D. Set as below in Network menu. Set Baud Rate Dome : 9600 Mux : 9600 DVR485 : 9600 DVR232 : 9600 Com Port Dome : Dome Mux : None DVR485 : AUX IN DVR232 : ADR 4) How to setup ADR - Switch the ADR on. - Press the Menu button. Input password according to the instruc

Summary of the content on the page No. 18

Select “Camera” on the Device menu. Unit ID should be 1 up to 99. Unit ID is not allowed number “0”. Set “PTZ Device” and “ID” of the dome camera. Select RS232/RS485 after PTZ is installed, and then set-up as below table. 18

Summary of the content on the page No. 19

RS232/RS485 Baud Rate Parity Data Stop Usage RS232 9600 None 8 1 Remote Control RS485 9600 None 8 1 PTZ Control 5) After setting Unit ID, Camera, and RS232/RS485, installing dome camera is basically completed. Please refer to the manual of ADR for the other installation. 6) Press the related number of the controller which is correspondent to unit ID of ADR. Then press DVR button and adjust unit ID of the controller 7) Make sure if any change is appeared on screen when you press

Summary of the content on the page No. 20

D. Set as below in Network menu. Set Baud Rate Dome : 9600 Mux : 9600 DVR485 : 9600 DVR232 : 9600 Com Ports Dome : Dome Mux : None DVR485 : AUX IN DVR232 : SDR 4) How to setup SDR - Switch the SDR on. - Press the Menu button. Input password according to the instruction. (Factory setting is 4321) - If the below screen is appeared, set “Quick Setup” to “Off”. If press OK after putting Quick Setup to off status, the belo


Alternative user manuals
# User manual Category Download
1 3M EM 550GPL User manual Mouse 3
2 3M EM 550GPS User manual Mouse 1
3 Sony PEGA-KB100 User manual Mouse 3
4 Sony 263 User manual Mouse 0
5 Sony User manual Mouse 1
6 Sony PCGA-UMS3 User manual Mouse 2
7 Sony SMU-CL2 User manual Mouse 1
8 Sony PEGA-KB20 User manual Mouse 0
9 Sony SMU-CM2 User manual Mouse 1
10 Sony Wireless LaserVGPWMS10W User manual Mouse 0
11 Acer LZ20400161 User manual Mouse 0
12 Sony BLUETOOTH VGP-BMS55 User manual Mouse 129
13 A4 Tech. Wireless 1-Wheel User manual Mouse 5
14 A4 Tech. NB-30 User manual Mouse 8
15 A4 Tech. X-708 User manual Mouse 9