Operating Instructions
HOB
Contents
GB
Installation, 2-6
Positioning
GB
Electrical connections
Gas Connection
English, 1
Technical data
Characteristic of the burners and nozzles
Description of the appliance, 7
Overall view
Start-up and use, 8
Practical Advise on Using the Burners
Precautions and tips, 9
General safety
Disposal
Maintenance and care, 10
PI 640 A GB
Switching the appliance off
PI 640 TC GB
Cleaning the appliance
Greasing the Taps
Assistance, 11
Краткое содержание страницы № 2
Installation ! Before operating your new appliance please read this The hob may be located in a kitchen, a kitonen/diner GB instruction booklet carefully. It contains important or bed sitting room, but not in a bathroom or shower information for safe use, installation and care of the room. appliance. The furniture standing next to the unit, that is higher than the working boards, must be placed at least ! Please keep these operating instructions for future 600 mm from the edge of the board.
Краткое содержание страницы № 3
45 mm. Front Electrical Connection for Gas Cooktop GB Fit the supply cord with a standard plug for the demand rate indicated on the rating plate or connect it directly to the electrical mains. In the latter case, a single pole switch must be placed between the appliance and the mains, with a minimum opening between the contacts of 3 mm in compliance with current safety codes (the earthing wire must not be interrupted by the switch). The power supply cord must be positioned so that it does not re
Краткое содержание страницы № 4
Gas Connection Adapting the Cooktop for Different Types of Gas GB The cooktop should be connected to the gas supply To adapt the cooktop to a different type of gas than by an authorized installer. During installation of this that for which it was designed, (see the sticker under product it is essential to fit an approved gas tap to the hob or on the packaging), the burner nozzles must isolate the supply from the appliance for the be changed, as follows: convenience of any subsequent removal or s
Краткое содержание страницы № 5
! If the gas pressure is different than that prescribed, a DATA PLATE GB pressure regulator must be installed at the source, in Class: II2H3+ compliance with national standards governing the use Rated power kW (1): of piped gas regulators. Gas section 8,05 (585 g/h - G30) (575 g/h - G31) Electrical section voltage: 220-240V ~ 50/60Hz This appliance conforms to the following European Economic Community directives: - 73/23/EEC of 19/02/73 (Low Voltage) and subsequent amendments; - 89/336/
Краткое содержание страницы № 6
Characteristic of the burners and nozzles GB Table 1 Liquid Gas Natural Gas Burner Diameter Thermal power By-Pass Nozzle Flow* Nozzle Flow* (mm) kW (p.c.s.*) 1/100 1/100 g/h 1/100 l/h Nomin. Ridot. (mm) (mm) *** ** (mm) Fast (R) 100 3,00 0,70 41 87 218 214 128 286 Semi Fast (S) 75 1,90 0,40 30 70 138 136 104 181 Auxiliary (A) 51 1,00 0,40 30 52 73 71 76 95 Triple Crown (TC) 130 3,25 1,30 57 91 236 232 133 309 Nominal (mbar) 28-30 37 20 Supply Minimum (mbar) 20 25 17 Pressures Maximum (mbar) 35 4
Краткое содержание страницы № 7
Description of the appliance Overall view GB Support Grid for Cookware Gas Burners Control Knobs for Gas Burners Ignition Button for Gas Burners Ignitor for Gas Burners 7
Краткое содержание страницы № 8
Start-up and use The position of the corresponding gas burner is Practical Advise on Using the Burners GB indicated on each control knob. For best performance, follow these general guidelines: Gas Burners Use the appropriate cookware for each burner (see The burners differ in size and power. Choose the most table) in order to prevent the flame from reaching appropriate one for the diameter of the cookware the sides of the pot or pan; being used. The burner can be regulated with the corresondin
Краткое содержание страницы № 9
Precautions and tips ! This appliance has been designed and Always make sure pan handles are turned towards GB manufactured in compliance with international safety the centre of the hob in order to avoid accidental standards. The following warnings are provided for burns. safety reasons and must be read carefully. Avoid closing the cover (if present) while the gas burners and electric plates are still warm. General safety Do not use cookware with uneven or deformed This manual is for a c
Краткое содержание страницы № 10
Maintenance and care Switching the appliance off Greasing the Taps GB Disconnect your appliance from the electricity supply The taps may jam in time or they may become difficult before carrying out any work on it. to turn. If so, the tap itself must be replaced. ! This operation must be performed by a technician Cleaning the appliance authorised by the manufacturer. ! Do not use abrasive or corrosive detergents, stain removers, anti-rust products, powder detergents or sponges with abrasive surfa
Краткое содержание страницы № 11
Assistance It may occur that the cooktop does not function or does not function properly. Before calling customer service for GB assistance, lets see what can be done. First of all, check to see that there are no interruptions in the gas and electrical supplies, and, in particular, that the gas valves for the mains are open. The burner does not light or the flame is not uniform around the burner. Check to make sure that: The gas holes on the burner are not clogged; All of the movable parts t
Краткое содержание страницы № 12
10/2004 - 195045883.00 XEROX BUSINESS SERVICES GB 12