Краткое содержание страницы № 1
GB 18-11-2003 13:57 Pagina 1
CF 210
CF 210
• Use and maintenance manual . . . .pag. 4
• Mode d’emploi et d’entretien . . . . .pag. 15
• Instrucciones de uso . . . . . . . . . .pag. 21
• Manual de instruções . . . . . . . . . .pag. 41
• Istruzioni per l’uso . . . . . . . . . . . .pag. 54
Краткое содержание страницы № 2
GB 18-11-2003 13:57 Pagina 2 Important safeguards • Use this appliance only as described in this instruction manual. As with any electrical appliance, the instructions aim to cover as many eventualities as possi- ble. Caution and common sense should be used when operating and installing this air condi- tioner. • This appliance has been manufactured to cool and dehumidify domestic environments and should not be used for other purposes. • It is dangerous to alter or modify the unit's characteri
Краткое содержание страницы № 3
GB 18-11-2003 13:57 Pagina 3 Introduction The portable air conditioner is a compact unit for regulating air temperature and humidity. Its extremely flexible characteristics make it easy to use at any time and in any room. It can be operated in multiple modes including cooling, dehumidifying and ventilating. The appliance has been designed for dome- stic use and may be used in the home, office, etc. It must be connected to an outlet with an impedance of less than 0.197 Ohms. If necessary, cons
Краткое содержание страницы № 4
GB 18-11-2003 13:57 Pagina 4 Description DESCRIPTION OF PARTS Front Control panel Air flow direction fins (right hand – left hand) Air outlet Air flow direction fins (high – low) Handle Water tank Castors Back Top air intake grille for cooling, dehumidifying and ventilating. Hot air outlet Connector for supplementary water tank Bottom air intake grill 4
Краткое содержание страницы № 5
GB 18-11-2003 13:57 Pagina 5 Control panel All functions of the unit can be controlled from the control panel or the remote control unit (certain models only). SET TEMP buttons These buttons can MODE KEY TIMER ON/OFF FAN SPEED button SWING button be used to set the Press this button to button Press this button to required room tem- Press this button to select the various Press this button to perature in a range distribute the air flow set the speed of the activate the timer operating modes: b
Краткое содержание страницы № 6
Краткое содержание страницы № 7
GB 18-11-2003 13:57 Pagina 7 Operation SETTING THE REMOTE CONTROL CLOCK Remove the cover of the battery compartment on the back of the remote control unit. After inserting two 1.5 V alkaline batteries in the compartment, the clock is automatically set at 12:00. If you want to set the time to 10:30, proceed as follows: Press the CLK button (in the battery compart- ment) with a pointed object such as a pencil. 1 The time indicator on the display flashes and the CLK ACL correct time can be set.
Краткое содержание страницы № 8
GB 18-11-2003 13:57 Pagina 8 Operation TIMER FUNCTION When the air conditioning unit is off (but plug- ged into the outlet), to turn it on at the required time press the "TIMER ON/OFF" button (" " will appear on the display), then press the " TIMER HOUR" button until the number of hours to elapse before the appliance comes on appears on the display. Vice versa, when the air conditioning unit is on, to turn it off at the required time press the "TIMER ON/OFF" button (" " will
Краткое содержание страницы № 9
Краткое содержание страницы № 10
Краткое содержание страницы № 11
GB 18-11-2003 13:57 Pagina 11 Installation CONDENSATION DRAINAGE 3. Do not remove the cap of the tube in the When the air conditioning unit is operating in water tank compartment (present in certain air conditioning or dehumidifying mode, the models only) while the unit is operating with condensation is collected in a special tank. condensation collecting in the tank as this When the tank is full, the "tank full" indicator could lead to leaks of water. light on the control panel flashes. Remo
Краткое содержание страницы № 12
GB 18-11-2003 13:57 Pagina 12 Maintenance MAINTENANCE END OF SEASON PROCEDURE •Turn the appliance off and unplug from 1. Turn the appliance off and disconnect the outlet before cleaning. from the outlet by unplugging from the • Make sure the unit is disconnected from all outlet. voltage before proceeding with mainte- 2. In models with a continuous condensation nance. This avoids the risk of electric drain tube only, before emptying the con- densation from the tank, remove the cap shock. from
Краткое содержание страницы № 13
GB 18-11-2003 13:57 Pagina 13 Troubleshooting Before contacting an authorized technical service center, check the following: Problem Check Solution The appliance does not • If there is a power outage work. • Check it no longer occurs • If the plug is not correctly • Plug into the outlet inserted in the outlet • If the outlet switch or the • Check the outlet switch or switch on the air conditio- turn the air conditioning ning unit is off. unit switch on • If the condensation tank •Empty the w
Краткое содержание страницы № 14
GB 18-11-2003 13:57 Pagina 14 Limited Warranty De’Longhi is the distributor of Kenwood home appliances. This warranty applies to all home appliances with De’Longhi or Kenwood brand names. FOR CONTIGUOUS UNITED STATES ONLY Limited Warranty We warrant each De’Longhi AIR CONDITIONER to be free from defects in material and workman- ship. From the purchase date, our obligation under this warranty is to provide one (1) year free parts and labor on the entire AIR CONDITIONER, with an additional