Краткое содержание страницы № 1
Operation/Reference Guide
®
Modero NXD-500i
G4 Touch Panel
5" Wall/Flush Mount Touch Panel with
Intercom
Initial Release: 11/3/2008
Touch Panels
Краткое содержание страницы № 2
AMX Limited Warranty and Disclaimer AMX warrants its products to be free of defects in material and workmanship under normal use for three (3) years from the date of purchase from AMX, with the following exceptions: • Electroluminescent and LCD Control Panels are warranted for three (3) years, except for the display and touch overlay components that are warranted for a period of one (1) year. • Disk drive mechanisms, pan/tilt heads, power supplies, and MX Series products are warranted for a pe
Краткое содержание страницы № 3
Table of Contents Table of Contents Introduction ........................................................................................................1 NXD-500i Specifications ........................................................................................... 3 Front Bezel Button.................................................................................................... 5 Ethernet and mini-USB Ports ..............................................................................
Краткое содержание страницы № 4
Table of Contents Master Connection section - NetLinx Master Ethernet IP Address - Auto Mode........... 36 Using G4 Web Control to Interact with a G4 Panel ................................................ 37 Using the NetLinx Master to control the G4 panel ................................................. 38 Upgrading Modero Firmware ...........................................................................43 Upgrading the Firmware via the USB port...............................................
Краткое содержание страницы № 5
Table of Contents Refreshing the Panel Statistics ...................................................................................... 73 Clearing the Panel Statistics.......................................................................................... 73 Connection Utility Page ................................................................................................ 74 Using the Connection Utility ....................................................................................
Краткое содержание страницы № 6
Table of Contents iv NXD-500i 5" Wall/Flush Mount Touch Panel with Intercom
Краткое содержание страницы № 7
Introduction Introduction The NXD-500i 5" Modero Wall/Flush Mount Touch Panel with Intercom (FG2261-02) is a widescreen full-color mini-touch panel with full sound and intercom capability (FIG. 1). It offers the same perimeter footprint as the NXD-CV5, but with a shallower mounting depth. Faceplate Microphone Touch screen Button Trim Ring Speaker Front Bezel button FIG. 1 NXD-500i Color Video Touch Panel This panel includes a built-in microphone, speakers, a mini-USB port for programming and
Краткое содержание страницы № 8
Introduction Locking tabs Touch screen Button trim ring Front Bezel button Back box FIG. 2 NXD-500i Color Video Touch Panel - Schematics FIG. 3 shows the connectors located on the NXD-500i Modero panel. The mini-USB port is used both for programming the touch panel and for audio output. The mini-USB port automatically detects the presence of a headphone adaptor, allowing the port to be used for headphone connectivity. Ethernet 10/100 port Mini-USB port Back box FIG. 3 NXD-500i Color Video To
Краткое содержание страницы № 9
Introduction Key features include: Support of AMX's 4th generation (G4) graphics which provide higher brightness, richer colors, and deeper contrast. The new G4 graphics technology is supported by the TPDesign4 Touch Panel Design application, available for download from www.amx.com. Display of images on a large 16:9 image format, while providing a wide 90-degree top-to- bottom viewing angle. A front panel light sensor, motion sensor, IR receiver and a Sleep/Setup Access button. Utilizatio
Краткое содержание страницы № 10
Introduction Specifications for NCXC-500i 5" Widescreen Video Touch Panel (Cont.) Supported Audio Sample • 48000Hz, 44100Hz, 32000Hz, 24000Hz, 22050Hz, 16000Hz, 12000Hz, Rates: 11025Hz, and 8000Hz. Intercom: • Full duplex VoIP capabilities. Front Panel Components: Light sensor: • Motion-sensitive light detector for automatic adjustment of the panel brightness (a dim room results in a dimmer LCD display, and a bright room results in a brighter LCD display). Note: The light sensor can be adjus
Краткое содержание страницы № 11
Introduction Specifications for NCXC-500i 5" Widescreen Video Touch Panel (Cont.) Included Accessories: • NXD-500i Installation Guide (93-2261-02) • Front Bezel (60-2261-11) Other AMX Equipment: • CB-TP5i Rough-In/Wallbox (FG038-11) • Back Cover for CB-TP5i Rough-In/Wallbox (FG038-12) • PS-POE-AF PoE Injector (FG423-80) • CC-USB Type-A to Mini-B 5-wire programming cable (FG10-5965) • USB to Headphone Adaptor (FG5966-23) • NXA-RK5 Rack Mount Kit for 5" Wall Mount panels (FG2904-55): - 5" Rackmoun
Краткое содержание страницы № 12
Introduction 6 NXD-500i 5" Wall/Flush Mount Touch Panel with Intercom
Краткое содержание страницы № 13
Installation Installation While the NXD-500i is designed to fit into pre-existing NXD-CV5 touch panel sites, the actual installation differs from that of the NXD-CV5 is several significant ways. The NXD-500i can be installed either directly into the (optional) CB-TP5i Rough-In Box or another solid surface environment, using either solid surface screws or the included locking tabs for different mounting options. For more information, please refer to the NXD-500i User Manual, available at www.
Краткое содержание страницы № 14
Installation Removing the Faceplate In certain circumstances, the Faceplate must be removed and replaced with a new faceplate. Because the device is installed against a wall, the faceplate must be removed carefully to prevent the two top prongs on the underside of the Faceplate from being broken. To remove the faceplate: 1. Gently lift up on the faceplate from the bottom. Do NOT pull up from the sides or the top. 2. Let the faceplate fall forward from the top of the device and let it pivot fro
Краткое содержание страницы № 15
Installation Installation of an NXD-500i Touch Panel The NXD-500i can be installed either directly into the (optional) CB-TP5i Rough-In Box or other solid surface environment, using solid surface screws or the included locking tabs as mounting options. The following sections describe mounting the touch panel directly into a pre-wall rough-in box, a solid surface, drywall, or an NXA-RK5 Rack Mount Kit. Pre-Wall Installation of the Rough-In Box The CB-TP5i Rough-In Box (FG038-11) is an option
Краткое содержание страницы № 16
Installation 5. Install the drywall/sheetrock before inserting the main NXD-500i device into the CB-TP5i. Installing the NXD-500i panel within a Rough-In Box The Rough-In Box must be mounted prior to continuing this section. Refer to the procedures in the Pre-Wall Installation of the Rough-In Box section on page 9 for detailed pre-wall installation instructions. Verify that all necessary cables have been threaded through the knockouts on the left of the Rough-In Box and the connections have b
Краткое содержание страницы № 17
Installation with the wall: this ensures that the locking tabs will tighten up against the inside of the wall. The back box is clear to allow visual confirmation that the tabs have been extended and are gripping the wall. This also allows visual confirmation if the entire assembly has to be removed from the wall for any reason. The maximum recommended torque to screw in the locking tabs on the back box is 105 IN-OZ [74 N-CM]. Applying excessive torque while tightening the locking tab screw
Краткое содержание страницы № 18
Installation Installing the NXD-500i into drywall Unlike most AMX touchpanels, the NXD-500i comes with a clear plastic backbox (FIG. 7) designed to attach the panel to standard drywall. This backbox has a locking tab on three of the four faces (missing only on the face containing the space for the connections) to help lock the backbox to the wall. These locking tabs are only extended AFTER the backbox is inserted into the wall. Locking tab screws Locking tabs - Closed Locking tabs - Open FIG.
Краткое содержание страницы № 19
Installation FIG. 8 NXD-500i Wall Mount panel dimensions Making sure that the actual cutout opening be slightly smaller than the provided dimensions is highly recommended. This action provides the installer with a margin for error if the opening needs to be expanded. Too little drywall removed is always better than too much. 3. Remove the Faceplate/bezel (A in FIG. 9) from the main NXD-500i device (B in FIG. 9) by gripping the faceplate and pulling up and then out with gentle outward force.
Краткое содержание страницы № 20
Installation Do not disconnect the connectors from the touch panel. The unit must be installed with the attached connectors before being inserted into the drywall. 7. Push the back box into the wall opening. Insure that the locking tabs lie flush against the back box. 8. Extend the locking tabs on the sides of the back box by tightening the screws inside the box. Not all of the tabs must be extended to lock the back box in place, but extending a minimum of the top and bottom tabs is highly r