ADDENDUM
Addendum No.: C1588M
Date: May 5, 2005
Manuals Affected: KBD300A Universal Keyboard – C527M-L
KBD4000 Genex Multiplexer Keyboard - C1921M-G
Manual Update: ECO 05-10910 optimizes joystick performance whenever you power up the KBD300A and
KBD4000. It also provides an automatic calibration mode.
Automatic Calibration of the Joystick
The KBD300A and KBD4000 will calibrate the joystick automatically on power-up and every 30 minutes of
inactivity. This is the default operation of
Краткое содержание страницы № 2
® KBD4000 ® Genex Multiplexer Keyboard Installation/ Operation Manual C1921M-G (1/04) Pelco World Headquarters • 3500 Pelco Way, Clovis, CA 93612-5699 USA • www.pelco.com USA & Canada: Tel: 800/289-9100 • Fax: 800/289-9150 International: Tel: 1-559/292-1981 • Fax: 1-559/348-1120
Краткое содержание страницы № 3
2 Pelco Manual C1921M-G (1/04)
Краткое содержание страницы № 4
CONTENTS Section Page IMPORTANT SAFEGUARDS AND WARNINGS ........................................................................ 4 REGULATORY NOTICES ........................................................................................................... 4 DESCRIPTION ........................................................................................................................... 5 INSTALLATION .........................................................................................
Краткое содержание страницы № 5
IMPORTANT SAFEGUARDS AND WARNINGS Prior to installation and use of this product, the following WARNINGS should be observed. 1. Installation and servicing should only be done by qualified service personnel and conform to all local codes. 2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X ,6 or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to rain and moisture. 3. Only use replacement parts recommended by Pelco. 4. After replacem
Краткое содержание страницы № 6
DESCRIPTION ® The KBD4000 Genex Multiplexer Keyboard is a full-function keyboard controller for the MX4000 Genex Multiplexer and MX4000SVR Genex Multiplexer Server. This manual covers the KBD4000 keyboard’s operation with both duplex and simplex models of the multiplexer. The differences, as they pertain to the keyboard, are indicated as necessary. The mode of operation depends on whether the keyboard is connected to a multiplexer or to a server. (See Modes of Operation for an explanation.) In a
Краткое содержание страницы № 7
INSTALLATION The following parts are supplied: 1 KBD4000 keyboard 1 25-foot (7.6 m) data cable 1 MODES OF OPERATION The mode of operation depends on whether the keyboard is connected to a multiplexer or to a server. Multiplexer Mode A single keyboard is plugged into the back of a Genex MX4000 Multiplexer. Multiplexer Server Mode Up to four keyboards can be connected to the back of a Genex MX4000SVR Multiplexer Server. Each keyboard connected to the remote keyboard port requires a KBDKIT(-X). P
Краткое содержание страницы № 8
UNUSED Leave switch 5 OFF. It is not used. TURBO MODE Set switch 6 ON to enable the turbo (extra fast) pan feature or OFF to disable. CAMERA ADDRESS MODE There are two modes for addressing cameras: • Set switch 7 ON if you want to address all cameras consecutively from 1-256 (refer to Table A). • Set switch 7 OFF if you want to address cameras in groups of 16 according to the multiplexer to which they are connected. For example, multiplexer 1, cameras 1-16; multiplexer 2, cameras 1-16, etc. Tabl
Краткое содержание страницы № 9
1B DO A MULTIPLEXER SERVER MODE INSTALLATION ADDRESS #1 (LOCAL) CONTROLS MONITOR 1 LOCAL KEYBOARD 1234567 ADDRESS #2 (REMOTE) ADDRESS #3 (REMOTE) ADDRESS #4 (REMOTE) CONTROLS MONITOR 2 CONTROLS MONITOR 3 CONTROLS MONITOR 4 T+ T R- R+ 1234567 1234567 1234567 1 TX+ 1 TX+ 1 TX+ 2 TX- 2 TX- 2 TX- 3 12VAC 3 12VAC 3 12VAC 4 12VAC 4 12VAC 4 12VAC 5 GND 5 GND 5 GND 6NC 6NC 6NC 7 RX- 7 RX- 7 RX- MULTIPLEXER KBDKIT WALL BLOCK 45 3 6 2 7 1 8 00017 Figure 2. Connecting Keyboards to the Server If the keyb
Краткое содержание страницы № 10
3. Replace the cover on the back of the keyboard. 4. Connect the keyboard to the MX4000SVR Multiplexer Server. You can connect up to four keyboards to the server—one to the server’s LOCAL KEYBOARD port and three to its REMOTE KEYBOARD(S) port, or all four to the remote. LOCAL KEYBOARD PORT CONNECTION Plug one end of the 25-foot (7.6 m) data cable with RJ-45 connectors supplied with the keyboard into the back of the keyboard. Plug the other end into the LOCAL KEYBOARD port on the server. Refer to
Краткое содержание страницы № 11
® 3 SETTING COAXITRON CONTROL OF CAMERAS NOTE: If you have a multi- The KBD4000 keyboard provides Coaxitron control of pan, tilt, and lens functions. There are three Coaxitron format settings, which are set in the Camera Setup section. plexer server, you must en- ter the Camera menu from Standard Use for moveable cameras controlled by 15-bit standard Coaxitron the multiplexer’s front panel. receivers, such as the CX9000 Series, the PT7700, and the ED25/27/ Then you can program the 28/29. The
Краткое содержание страницы № 12
PROGRAMMING This section applies only to programming the multiplexer. The multiplexer can be NOTE: To program a multi- programmed from the keyboard or from the multiplexer’s front panel. To program the plexer if a multiplexer server multiplexer from the front panel, refer to the multiplexer manual. To program the is installed, you must enter multiplexer server, refer to the server manual. programming mode from the multiplexer’s front panel. Programming lets you configure the multiplexer (from t
Краткое содержание страницы № 13
MENUS NORMAL REC. SPEED 2/6/8 Hr ALARM REC. SPEED 2/6/8 Hr VCR SETUP VCR TYPE UNIVERSAL VCR VIDEO FORMAT COMPOSITE VCR SWITCH PULSE DISABLED ALARM HANDLING RECORD ALARMS AS A PRIORTIY ALARM RECORD TIME ALARM DURATION LIVE/VCR CONFIGURE CUSTOM VCR PLAYBACK FORMAT PELCO MONITOR UNIT MAIN SPOT SEQ VIEW PATTERN PRESET ON OFF 1 23 NEAR FAR 4 5 6 OPEN
Краткое содержание страницы № 14
SYSTEM SETUP (VIEW KEY) 2/6/8 Hr *2,6,or 8 Hr 120 Hr 2/6/8 Hr 12 Hr 168 Hr 16 Hr 180 Hr MAIN MONITOR VIDEO 18 Hr 240 Hr MAIN MONITOR DISPLAY HIGH RESOLUTION 24 Hr 360 Hr 48 Hr 480 Hr 72 Hr 600 Hr 84 Hr 720 Hr 96 Hr 960 Hr ** ** HIGH RESOLUTION RESET ACTIVITY DETECTION ALL CH TO REDUCED FLICKER * 2/6/8 HR FOR NTSC/EIA MODEL MULTIPLEXERS, 3 HR FOR PAL/CCIR MODELS. REMAINING RECORD SPEEDS DEPEND UPON VCR MODEL. ** NOT SHOWN ON DUPLEX MONOCHROME MODELS OR SIMPLEX MULTIPLEXERS Figure 5. Ba
Краткое содержание страницы № 15
Record Speeds Sets the speed at which the VCR normally records video and at which it records when there is an alarm(s). Setting the speeds in the System Setup menu also sets the speeds in the Record Setup and Custom VCR Setup menus. Main Monitor Video (Duplex Color Models Only) COMPOSITE is standard video on coaxial cable. SVHS is higher resolution video on a special cable. Main Monitor Display The options are HIGH RESOLUTION and REDUCED FLICKER. Select REDUCED FLICKER when there is flickering o
Краткое содержание страницы № 16
ADVANCED SYSTEM SETUP (VIEW KEY) DATE FORMAT MM-DD-YY PASSWORD DISABLED FRONT PANEL CONTROL ENABLED MAIN MONITOR DISPLAY SEQUENCE RESPONDS TO NONE BLANK TRACK MAIN SPOT MONITOR DISPLAY SEQUENCE RESPONDS TO ALARMS *** AUX MONITOR DISPLAY BLANK *** RESPONDS TO ACTIVITY CAMERA TYPES ALL COLOR BLANK CAM 1 UNIT ID 001 COMM. TYPE MASTER (KBD-T/D) CAM 16 SEQUENCE RELAY OUTPUT ALARM ALL COLOR* COLOR & B/W RESERVED 001–240 MASTER (KBD-T/D)** (1) SLAVE (2) * ALL B/W SHOWN ON MONOCHROME MODELS. (1) SIMPLEX
Краткое содержание страницы № 17
Spot Monitor Display • Select BLANK, SEQUENCE, or TRACK MAIN if you want the spot monitor to switch to cameras that have alarms or activity detection. Then under RE- SPONDS TO, select ALARMS, ACTIVITY, or ALARMS/ACTIVITY. • Select NONE if you are using the spot for normal video and you do not want alarms or activity detection to override what you are watching. The options are defined as follows: • BLANK – Lets you view an individual camera, but you cannot run a sequence. An alarm or activity det
Краткое содержание страницы № 18
Comm. Type • In polled communication mode (switch 4 off), one multiplexer (any one) must be the master. Only one multiplexer can be master; all others must be slaves. The master multiplexer communicates with the slave multiplexers. • In non-polled communication mode (switch 4 on), all multiplexers must be slaves (the keyboard is master). The default is MASTER for duplex models and MASTER (KBD T/D) for simplex models. Relay Output This operates the relay on the back of the multiplexer. The relay
Краткое содержание страницы № 19
RECORD SETUP (LIVE/VCR KEY) *2, 6, or 8 Hr 24 Hr 96 Hr 240 Hr 12 Hr 48 Hr 120 Hr 360 Hr 16 Hr 72 Hr 168 Hr 480 Hr 18 Hr 84 Hr 180 Hr 600 Hr NORMAL REC. SPEED 2/6/8 Hr 720 Hr ALARM REC. SPEED 2/6/8 Hr 960 Hr SEE TABLE C VCR SETUP ** VCR TYPE UNIVERSAL ** VCR VIDEO FORMAT
Краткое содержание страницы № 20
VCR Switch Pulse • ENABLED + means the multiplexer waits for a positive head switching pulse from the VCR. If the multiplexer does not get a pulse from the VCR (because of a broken wire or the VCR does not give a pulse in some modes), it may appear the multiplexer is not working properly. • ENABLED – (minus sign) means the multiplexer waits for a negative head switching pulse from the VCR. • DISABLED means the VCR head switching pulse is not used. Alarm Handling This determines how alarms are re