Краткое содержание страницы № 1
RuggedPower™ RP100
Hardware Installation Guide
Revision 100 - June 13, 2011
www.RuggedCom.com
Краткое содержание страницы № 2
RuggedPower™ RP100 RuggedPower™ RP100: Hardware Installation Guide Copyright © 2011 RuggedCom Inc. All Rights Reserved Dissemination or reproduction of this document, or evaluation and communication of its contents, is not authorized except where expressly permitted. Violations are liable for damages. All rights are reserved, particularly for the purposes of patent application or trademark registration. This document contains proprietary information, which is protected by copyright. All rights a
Краткое содержание страницы № 3
RuggedPower™ RP100 Table of Contents Cautions ..................................................................................................................................... 6 1. Product Overview ................................................................................................................... 7 1.1. Functional Overview .................................................................................................... 7 1.2. RP100 Front Panel Description .................
Краткое содержание страницы № 4
RuggedPower™ RP100 List of Figures 1.1. RP100 Front Panel ............................................................................................................. 7 1.2. RP100 Top View ................................................................................................................. 8 1.3. RP100 Side View ................................................................................................................ 8 2.1. RP100 DIN Rail Mounting .............................
Краткое содержание страницы № 5
RuggedPower™ RP100 List of Tables 1.1. RP100 Front Panel LED ..................................................................................................... 7 2.1. RJ45 Ethernet Port Pinout ................................................................................................ 11 3.1. RP100 HI AC/DC Power Supply Specifications ................................................................ 12 3.2. RP100 LO DC Power Supply Specifications ...........................................
Краткое содержание страницы № 6
Cautions Cautions Caution: Service This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by RuggedCom Inc. could invalidate specifications, test results, and agency approvals, and void the user’s authority to operate the equipment. Should this device require service, refer to Appendix A, Warranty in this guide. Caution: Physical Access This product should be installed
Краткое содержание страницы № 7
1. Product Overview 1. Product Overview 1.1. Functional Overview The RuggedPower™ RP100 is a wide mouth power injector. Data presented on the 10/100 TX port is coupled with power on the RuggedMax port. This allows for a single CAT-5E STP (shielded twisted pair) cable between the RP100 and the powered device, providing both data and power. The RP100 can be ordered with one of two power supply options: • “LO” power supply option: the RP100 operates on DC power in the range of 10 VDC to 60 VDC and
Краткое содержание страницы № 8
1. Product Overview 1.3. RP100 Top View Figure 1.2. RP100 Top View 1.4. RP100 Side View Figure 1.3. RP100 Side View RuggedCom® RuggedPower™ 8 RP100 Installation Guide Rev100
Краткое содержание страницы № 9
2. Installation 2. Installation 2.1. DIN Rail Mounting The RP100 comes with a standard DIN rail mounting bracket. Figure 2.1, “RP100 DIN Rail Mounting” details the mounting configuration for a standard 1" DIN rail. Figure 2.1. RP100 DIN Rail Mounting 2.2. AC Power Supply Wiring and Grounding This section applies only to RP100 units equipped with the “HI” power supply option. Figure 2.2. AC Power Supply and Ground Connections Connect the AC power supply as follows: 1. +/L = AC HOT, and is connect
Краткое содержание страницы № 10
2. Installation 2. -/N = AC NEUTRAL, and is connected to the NEUTRAL terminal of the AC power source. 3. Ground must be connected to the Safety Ground via a braided cable or other appropriate grounding wire. 4. Safety Ground should be connected to the power supply ground or equipment ground bus. 2.3. DC Power Supply Wiring and Grounding + Figure 2.3. DC Power Supply and Ground Connections Connect the DC power supply as follows: 1. +/L = DC (+), and is connected to the positive (+) terminal of th
Краткое содержание страницы № 11
2. Installation 2.4.2. RuggedMAX Power Port / IEEE802.3at Port The RuggedMax Power port takes data received on the 10/100 Base TX port and injects power on pins 4, 5 and 7, 8. CAT-5E STP (shielded twisted pair) cable should be used to connect this port to the powered device. For RP100 units with the “AT” IEEE802.3at-compliance option, the unit only delivers power when an IEEE802.3at-compliant powered device is attached. RuggedMax Power 10/100 Base Tx Pin Signal Pin Signal 1 +Tx 1 +Tx 2 -Tx 2 -Tx
Краткое содержание страницы № 12
3. Specifications 3. Specifications 3.1. Power Supply Specifications Power Output Power Minimum Input Maximum Input Fuse Rating Output Voltage Supply Type @ 85°C 90 VAC 264 VAC 3.15 A 54 V 25 W RP100 HI AC/DC 88 VDC 300 VDC 3.15 A 54 V 25 W Table 3.1. RP100 HI AC/DC Power Supply Specifications Power Output Power Minimum Input Maximum Input Fuse Rating Output Voltage Supply Type @ 85°C 24 W @ 12 Vin RP100 LO DC 10 VDC 60 VDC 5 A 54 V 36 W @ 24-48 Vin Table 3.2. RP100 LO DC Power Supply Specificat
Краткое содержание страницы № 13
3. Specifications 3.3. Physical Dimensions Figure 3.1. RP100 Dimensions RuggedCom® RuggedPower™ 13 RP100 Installation Guide Rev100
Краткое содержание страницы № 14
Appendix A. Warranty Appendix A. Warranty RuggedCom warrants this product for a period of five (5) years from the date of purchase. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. For warranty details, visit www.RuggedCom.com or contact your customer service representative. Should this product require service, contact the factory at: RuggedCom Inc. 300 Applewood Crescent Concord, Ontario Canada L4K 5C7