Preparation before use Before using the air conditioner, be sure to check and preset the following. Remote Controller presetting The remote controller is NOT presetting as Cooling Only Air Conditioner or Heat Pump by manufacturer. Each time after the remote controller replaces batteries or is energized, the Cooling indicator and Heating indicator will flashes alternately on LCD of the remote controller. User can preset the remote controller type depending on the air conditioner typ
Краткое содержание страницы № 3
JE T TIMER ON TIMER OFF CLOCK Safety precautions Symbols in this Use and Care Manual are interpreted as shown below. Be sure not to do. Be sure to follow this instruction. The feature of the appliance, Grounding is essential. instead of a fault. Warning: Incorrect handling could Pay attention to such a situation. cause a serious hazard, such as death, serious injury, etc. ON ON Use correct power supply in OFF OFF accordance with the rating plate requirement. Otherwise, serious faults or h
Краткое содержание страницы № 4
JET TIMER ON TIMER OFF CLOCK O ON N O OF FF F FAN MODE LOCK Identification of parts Indoor unit Air Intake Front Panel Emergency Panel Display Panel Air Outlet Vertical Adjustment Louver Horizontal Adjustment Louver Air Filter Remote Controller Air Intake Outdoor unit Pipes and Power Connection Cord Drain Hose Note: Condensate water drains at COOLING or DRY operation. Air Outlet The figures in this manual are based on the external view of a standard model. Consequently, the shape may d
Краткое содержание страницы № 5
Identification of parts UH series operating and display Run Indicator Timer Indicator It is on during operation. It lights up during the It flashes during set time. defrosting. Sleep Indicator Compressor indicator Temperature display It lights up when Display actual room It lights up when . unit is in sleep mode. temperarure. compressor is running. Display set temperature. The shape and position of the switches and indicators may vary from different models, but their function are similar
Краткое содержание страницы № 6
TIMER ON TIMER OFF CLOCK Remote controller Remote controller The remote controller transmits signals to the system. ON/OFF BUTTON 1 The appliance will be started when it is energized or will be stopped when it is in operation, if you press this button. MODE BUTTON 2 Press this button to select the operation mode. 1 O ON N 4 3 FAN BUTTON O OF FF F Used to select fan speed in sequence auto, high, medium or low. 2 3 ROOM TEMPERATURE 5 4 SETTING BUTTONS 6 th Used to adjust the room temperatur
Краткое содержание страницы № 7
SUPER TIMER ON T ME FF I R O CLOCK O ON N FAN MODE O OF FF F LOCK ON ON OF OFF F F FA AN N M MO OD DE E M MO OD DE E ON ON OF OFF F F FA AN N Remote controller Remote controller How to Insert the Batteries Remove the battery cover according to the arrow direction. Insert new batteries making sure that the (+) and (-) of battery are matched correctly. Reattach the cover by sliding it back into position. Note: Use 2 LR03 AA(1.5volt) batteries. Do not use rechargeable batteries. Replace batt
Краткое содержание страницы № 8
TIMER ON TIMER OFF CLOCK 3 Operation instructions Operation modes Selecting mode Each time MODE button is pressed, the operation mode is changed in sequence: COOLING DRY FAN ONLY HEATING Heating mode is NOT available for cooling only air conditioner. FAN mode Each time the "FAN" button is pressed, the fan speed is O ON N changed in sequence: O OF FF F High Medium Auto Low th At "FAN ONLY" mode, only "High","Medium" and "Low" are available. sense At "DRY" mode, Fan speed is set at "Low" a
Краткое содержание страницы № 9
TIMER ON TIM FF ER O CLOCK Operation instructions Airflow direction control Airflow direction control O ON N Vertical airflow is automatically adjusted to a certain angle O OF FF F in accordance with the operation mode after turning on the unit. The direction of airflow can be th Operation mode Direction of airflow also adjusted to your own se ns e FAN MODE requirement by pressing the 5 horizontal COOLING, DRY "SWING" button of the remote controller. *HEATING, downward FAN ONLY *Heating
Краткое содержание страницы № 10
TIMER ON TIMER OFF CLOCK Operation instructions 6th sense mode th Press the button, the unit enters 6th sense mode(fuzzy logic operation) directly regardless of sense the unit is on or off. In this mode, temperature and fan speed are automatically set based on the actual room temperature. Operation mode and temperature are determined by indoor temperature Heat pump models Indoor temperature Operation mode Target temperature HEATING 21 or below 22 22 O ON N O OF FF F 21 -23 FA
Краткое содержание страницы № 11
Operation instructions Timer mode It is convenient to set the timer on with TIMER ON/OFF buttons when you go out in the morning to achieve a comfortable room temperature at the time you get home. You can also set timer off at night to enjoy a good sleep. How to set TIMER ON TIMER ON button can be used to set the timer programming as wished in order to switch on the appliance at your desired time. i) Press TIMER ON button, "ON 12:00" flashes on the LCD, then you can press the o
Краткое содержание страницы № 12
TIMER ON TIMER ON TIMER OFF TIMER OFF CLOCK CLOCK Operation instructions SLEEP mode SLEEP mode SLEEP mode can be set in COOLING or HEATING operation mode. This function gives you a more comfortable environment for sleep. O ON N In SLEEP mode, The appliance will stop operation automatically after operating for 8 hours. Fan speed is automatically set at low speed. th sense *Set temperature will rise by 1 at most if the appliance operates in cooling FAN MODE mode for 2 hours constantly, th
Краткое содержание страницы № 13
Dangerous! Electric shock! Maintenance Front panel maintenance Air filter maintenance Cut off the power supply It is necessary to clean the air filter after using it for about 100 hours. Turn off the appliance first before disconnecting Clean it as follows: from power supply. a Stop the appliance and remove the air filter. Grasp position "a" and pull outward to remove the front panel. a Wipe with a soft and dry cloth. 1.Open the front panel. 2.Press the handle of the filter gently Use a dry
Краткое содержание страницы № 14
Protection Noise pollution Operating condition The protective device maybe trip and stop Install the air conditioner at a place that the appliance in the cases listed below. can bear its weight in order to operate more quietly. o Outdoor air temperature is over *43 C COOLING o Install the outdoor unit at a place where Room temperature is below 21 C the air discharged and the operation noise o Room temperature is below 18 C DRY would not annoy your neighbors. Do not place any obstacles in f
Краткое содержание страницы № 15
Troubleshooting The following cases may not always be a malfunction, please check it before asking for service. Trouble Analysis If the protector trip or fuse is blown. Please wait for 3 minutes and start again, Does not run protector device may be preventing unit to work. . If batteries in the remote controller exhausted. If the plug is not properly plugged. Is the air filter dirty? No cooling or Are the intakes and outlets of the air heating air conditioner blocked Is the temperature set p
Краткое содержание страницы № 16
air outlet distance from the wall should be over 500mm Installation instructions Installation diagram Distance from ceiling should be over 50 mm Distance from wall should be over 50mm Distance from the wall should be over 50mm Distance from floor should be over 2000mm Air intake distance from the wall Air intake distance from should be over 250mm the wall should be over 250mm over 250mm Above figure is only a simple presentation of the unit, it may not match the external appearance of the u
Краткое содержание страницы № 17
Select the best location Installation instructions Location for Installing Indoor Unit Where there is no obstacle near the air outlet and air can be easily blown to every corner. Indoor unit Where piping and wall hole can be easily arranged. Keep the required space from the unit to the ceiling and wall according to the installation diagram on previous page. Pipe length is Where the air filter can be easily removed. 15 meters Max. Keep the unit and remote controller 1m or more apart from
Краткое содержание страницы № 18
Installation instructions Indoor unit installation 1. Installing the Mounting Plate Decide an installing location for the mounting plate according to the indoor unit location and piping direction. Keep the mounting plate horizontally with a horizontal ruler or dropping line. . Drill holes of 32mm in depth on the wall for fixing the plate. Insert the plastic plugs to the hole, fix the mounting plate with tapping screws. Inspect if the mounting plate is well fixed. Then drill
Краткое содержание страницы № 19
Installation instructions Piping Joints Thermal Insulation: Wrap the piping joints with thermal insulation materials and then wrap with a vinyl tape. wrapped with vinyl type Thermal insulation Piping Thermal Insulation: Large pipe Thermal insulation a. Place the drain hose under the piping. tube b. Insulation material uses polythene foam over 6mm in thickness. Power cord Note: Drain hose is prepared by user. Small Drain pipe should point downward for easy drain flow. pipe Do not ar
Краткое содержание страницы № 20
Installation instructions 4. Connecting of the Cable Front panel Terminal (inside) Indoor Unit Connect the power connecting cord to the indoor unit by connecting the wires to the terminals on the control board individually in accordance with the outdoor unit Cabinet connection. Indoor unit Chassis Note: For some models, it is necessary to remove the cabinet to connect to indoor unit terminal. Outdoor Unit 1). Remove the access door from the unit by loosening the screw. Connect the wires