Краткое содержание страницы № 1
SH7144 Group FP-112B
User System Interface Board
HS7144ECH61H User’s Manual
Renesas Microcomputer Development Environment System
TM
SuperH Family/SH7144 Series
Rev.4.00
2004.1.29
Краткое содержание страницы № 2
Cautions Keep safety first in your circuit designs! 1. Renesas Technology Corp. puts the maximum effort into making semiconductor products better and more reliable, but there is always the possibility that trouble may occur with them. Trouble with semiconductors may lead to personal injury, fire or property damage. Remember to give due consideration to safety when making your circuit designs, with appropriate measures such as (i) placement of substitutive, auxiliary circuits, (ii) use of nonflam
Краткое содержание страницы № 3
IMPORTANT INFORMATION READ FIRST • READ this user's manual before using this user system interface cable. • KEEP the user's manual handy for future reference. Do not attempt to use the user system interface cable until you fully understand its mechanism. User System Interface Cable: Throughout this document, the term "user system interface cable" shall be defined as the following product produced only by Renesas Technology Corp. excluding all subsidiary products. • User system interface cab
Краткое содержание страницы № 4
LIMITED WARRANTY Renesas warrants its user system interface cables to be manufactured in accordance with published specifications and free from defects in material and/or workmanship. Renesas will repair or replace any user system interface cables determined to be defective in material and/or workmanship. User system interface cables are wearing parts which Renesas will not repair or replace if damaged and/or worn through use. The foregoing shall constitute the sole remedy for any breach of
Краткое содержание страницы № 5
State Law: Some states do not allow the exclusion or limitation of implied warranties or liability for incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may have other rights which may vary from state to state. The Warranty is Void in the Following Cases: Renesas shall have no liability or legal responsibility for any problems caused by misuse, abuse, misapplication, neglect, improper h
Краткое содержание страницы № 6
SAFETY PAGE READ FIRST • READ this user's manual before using this user system interface cable. • KEEP the user's manual handy for future reference. Do not attempt to use the user system interface cable until you fully understand its mechanism. DEFINITION OF SIGNAL WORDS This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. DANGER DANGER indicates an imminently hazardous
Краткое содержание страницы № 7
WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Do not repair or remodel the emulator product by yourself for electric shock prevention and quality assurance. 2. Always switch OFF the E6000H emulator and user system before connecting or disconnecting any CABLES or PARTS. 3. Always before connecting any CABLES, make sure that
Краткое содержание страницы № 8
Preface The HS7144ECH61H is a user system interface board that connects a user system for the SH7144 FP-112B package to the SH7046 E6000H emulator (HS7046EPH60H). i
Краткое содержание страницы № 9
Contents Section 1 Configuration.....................................................................................1 Section 2 Environmental Conditions.................................................................3 2.1 Setting Operating Voltage and Operating Frequency .......................................................3 Section 3 Product Specifications .......................................................................4 Drop in Vcc Level Detection Function:....................
Краткое содержание страницы № 10
Section 1 Configuration Figure 1 and table 1 show the configuration and components of the user system interface board for the FP-112B package. Please make sure you have all of these components when unpacking. EV-chip board Screws (M2.0 x 8 mm) with flat washers Screws (M2.0 x 12 mm) with flat washers Board Socket cover Spacer IC socket User system Figure 1 User System Interface Board for the SH7144 FP-112B Package 1
Краткое содержание страницы № 11
CAUTION Use an IC149-112C15333-0B socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the FP-112B package IC socket on the user system. Table 1 HS7144ECH61H Components No. Component Quantity Remarks With two spacers (2.6MP x 6 mm) 1 Board 1 2 IC socket 1 For the FP-112B package (to be mounted on the user system) 3 Socket cover 1 For the FP-112B package (for installing MCU) 4 Screws (M2.0 x 12 mm) 4 For fastening board (with four flat washers) 5 Screws (M2.0 x 8 mm) 4 For installing an FP
Краткое содержание страницы № 12
Section 2 Environmental Conditions Maintain the conditions in table 2 when using the emulator. Table 2 Environmental Conditions Item Specifications Temperature Operating: +10 to +35°C Storage: -10 to +35°C Humidity Operating: 35 to 80% RH, no condensation Storage: 35 to 80% RH, no condensation Vibration Operating: 2.45 m/s max. Storage: 4.9 m/s max. Transportation: 14.7 m/s max. Ambient gases There must be no corrosive gases present. 2.1 Setting Operating Voltage and Operating Frequency
Краткое содержание страницы № 13
Section 3 Product Specifications The specifications of this product are shown in table 3. Table 3 Product Specifications Item Specifications Target processor SH7144F Package FP-112B Function Level limitation: This function keeps the output signal from 3-V emulator system equal to or less than power supply voltage of the user system (Vcc). User-system operating Power supply voltage conditions Vcc: 3.0 to 3.6 V A drop in the Vcc level of the user system is detected when the power supply voltage
Краткое содержание страницы № 14
Section 4 User Interface Specifications The user system interface board incorporates a level conversion circuit supporting a low-voltage circuit. Accordingly, when connecting the user system to the emulator, pay attention to the signal delays and the number of FANINs and FANOUTs. 4.1 User System Interface Circuit The user system interface circuit of the user system interface board is shown below. (1) NMI and _RES 5Vcc UVcc HD151015 VccB VccA BA Emulator User system Figure 3 User System Inte
Краткое содержание страницы № 15
(3) AVcc and AN7 to AN0 5Vcc QS3384 AN7 to AN0 Emulator User system Vss AVss Figure 5 User System Interface Circuit for AVcc and AN7 to AN0 6
Краткое содержание страницы № 16
Section 5 Connection Procedures 5.1 Connecting User System Interface Board to User System WARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE BOARD is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. To con
Краткое содержание страницы № 17
5.1.2 Installing Cable Head CAUTION Check the location of pin 1 before inserting. Align pin 1 on the IC socket for an FP-112B package on the user system with pin 1 on the user system interface board, and insert the user system interface board into the IC socket on the user system, as shown in figure 6. 5.1.3 Fastening Cable Head CAUTION 1. Use a Phillip-type screwdriver whose head matches the screw head. 2. The tightening torque must be 0.098 N•m or less. If the applied torque cannot be accurate
Краткое содержание страницы № 18
Screws (M2.0 x 12 mm) with flat washers Board Pin 1 IC socket (IC149-112C15333-0B manufactured by User system YAMAICHI ELECTRONICS Co., Ltd.) Figure 6 Connecting User System Interface Board to User System 9
Краткое содержание страницы № 19
5.2 Connecting User System Interface Board to EV-Chip Board WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE BOARD is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. 2.
Краткое содержание страницы № 20
EV-chip board Connector No. EV-Chip Board Board Connector No. Connector No. UCN1 UCN1 UCN2 UCN2 Board Spacer User system Figure 7 Connecting User System Interface Board to EV-Chip Board 11