Краткое содержание страницы № 1
H8/3694, H8/36014 Group TNP-48
User System Interface Cable
for E6000 Emulator
HS36014ECN61H User’s Manual
Renesas Microcomputer Development Environment System
H8 Family / H8/300H Tiny Series
Rev.1.00
2003.12.19
Краткое содержание страницы № 2
Cautions Keep safety first in your circuit designs! 1. Renesas Technology Corp. puts the maximum effort into making semiconductor products better and more reliable, but there is always the possibility that trouble may occur with them. Trouble with semiconductors may lead to personal injury, fire or property damage. Remember to give due consideration to safety when making your circuit designs, with appropriate measures such as (i) placement of substitutive, auxiliary circuits, (ii) use of nonflam
Краткое содержание страницы № 3
? IMPORTANT INFORMATION READ FIRST • READ this user's manual before using this user system interface cable. • KEEP the user's manual handy for future reference. Do not attempt to use the user system interface cable until you fully understand its mechanism. User System Interface Cable: Throughout this document, the term "user system interface cable" shall be defined as the following product produced only by Renesas Technology Corp. excluding all subsidiary products. • User system interface c
Краткое содержание страницы № 4
LIMITED WARRANTY Renesas warrants its user system interface cables to be manufactured in accordance with published specifications and free from defects in material and/or workmanship. Renesas will repair or replace any user system interface cables determined to be defective in material and/or workmanship. User system interface cables are wearing parts which Renesas will not repair or replace if damaged and/or worn through use. The foregoing shall constitute the sole remedy for any breach of
Краткое содержание страницы № 5
State Law: Some states do not allow the exclusion or limitation of implied warranties or liability for incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may have other rights which may vary from state to state. The Warranty is Void in the Following Cases: Renesas shall have no liability or legal responsibility for any problems caused by misuse, abuse, misapplication, neglect, improper h
Краткое содержание страницы № 6
SAFETY PAGE READ FIRST • READ this user's manual before using this user system interface cable. • KEEP the user's manual handy for future reference. Do not attempt to use the user system interface cable until you fully understand its mechanism. DEFINITION OF SIGNAL WORDS This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. DANGER DANGER indicates an imminently hazardous
Краткое содержание страницы № 7
WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Do not repair or remodel the emulator product by yourself for electric shock prevention and quality assurance. 2. Always switch OFF the E6000 emulator and user system before connecting or disconnecting any CABLES or PARTS. 3. Always before connecting any CABLES, make sure that
Краткое содержание страницы № 8
Preface Thank you for purchasing this user system interface cable (HS36014ECN61H) for the Renesas’ original microcomputer H8/3694 group and H8/36014 group. The HS36014ECN61H is a user system interface cable that connects an H8/3694 group, H8/36014 group E6000 emulator (HS3664EPI61H; hereinafter referred to as the emulator) to the IC socket for a TNP-48 package for the H8/3694 group or H8/36014 group MCU on the user system. i
Краткое содержание страницы № 9
Contents Section 1 Configuration....................................................................................1 Section 2 Connection Procedures ......................................................................3 2.1 Connecting User System Interface Cable to Emulator Station..........................................3 2.2 Connecting User System Interface Cable to User System.................................................5 2.2.1 Installing IC Socket.................................
Краткое содержание страницы № 10
Section 1 Configuration CAUTION Use an NLPACK048SD socket (manufactured by Tokyo Eletech Corporation) for the TNP-48 package IC socket on the user system. Figure 1 shows the configuration of the HS36014ECN61H user system interface cable for the TNP-48 package. To emulator station CTS screws (M 3x6m)m for fastening the emulator station Cable body Screws (M2 x 01 mm) (for fastening cable head) Screws (M 2x6m)m Cable head Socket cover IC socket User system Figure 1 HS36014ECN61H User System In
Краткое содержание страницы № 11
Table 1 lists the HS36014ECN61H components. Please make sure you have all of these components when unpacking. Table 1 HS36014ECH64H Components No. Component Quantity Remarks 1 Cable body 1 Coaxial cable 2 Cable head 1 3 IC socket 1 For the TNP-48 package 4 Socket cover 1 For installing a TNP-48 packaged MCU 5 Screws (M2 x 10 mm) 4 For fastening cable head 6 Screws (M2 x 6 mm) 4 For installing a TNP-48 packaged MCU 7 CTS screws (M3 x 6 mm) 2 For fastening the emulator station 8 Guide pins (ϕ 0.8
Краткое содержание страницы № 12
Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on
Краткое содержание страницы № 13
Figure 2 Connecting User System Interface Cable to Emulator Station 4
Краткое содержание страницы № 14
2.2 Connecting User System Interface Cable to User System WARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. To connect the cable head to the user system,
Краткое содержание страницы № 15
2.2.1 Installing IC Socket After checking the location of pin 1 on the IC socket fasten it to the user system before soldering. CAUTION After confirming the location of pin 1 on the IC socket, apply epoxy resin adhesive to the end of the four projections at the bottom of the IC socket, and fasten it to the user system. Use the guide pins provided to decide where to install the IC socket, as shown in figure 3. Figure 3 Location Setting of IC Socket 6
Краткое содержание страницы № 16
2.2.2 Soldering IC Socket After fastening, solder the IC socket for a TNP-48 package to the user system. CAUTION Be sure to completely solder the leads so that the solder slops gently over the leads and forms solder fillets. (Use slightly more solder than the MCU.) 2.2.3 Inserting Cable Head CAUTION Check the location of pin 1 before inserting. Align pin 1 on the IC socket for a TNP-48 package on the user system with pin 1 on the user system interface cable head, and insert the user system inter
Краткое содержание страницы № 17
2.2.4 Fastening Cable Head CAUTION 1. Use the screwdriver provided for tightening screws. 2. The tightening torque must be 0.098 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening. If a screw is tightened too much, the screw head may break or an IC socket contact error may be caused by a crack in the IC socket solder. 3. If the emulator does not operate c
Краткое содержание страницы № 18
Fasten the user system interface cable head to the IC socket for a TNP-48 package on the user system with the four screws (M2 x 10 mm) provided. Each screw should be tightened a little at a time, alternating between screws on opposing corners. Take special care, such as manually securing the IC socket soldered area, to prevent the soldered IC socket from being damaged by overtightening the screws or twisting the components.s Figure 4 Connecting User System Interface Cable to User System 9
Краткое содержание страницы № 19
2.2.5 Fastening Cable Body Connect the cable body to the cable head. Figure 5 Fastening Cable Body 10
Краткое содержание страницы № 20
2.3 Recommended Dimensions for User System Mount Pad Figure 6 shows the recommended dimensions for the mount pad (footprint) for the user system with an IC socket for a TNP-48 package (NLPACK048SD: manufactured by Tokyo Eletech Corporation). Note that the dimensions in figure 6 are somewhat different from those of the actual chip's mount pad. 8.2 (min.) 6.1 (max.) 5.7 2- ϕ0.8 Hole for a guide pin 0.3 Unit: mm 0.5 0.5 × 11 = 5.5 Figure 6 Recommended Dimensions for Mount Pad 11 3.5 5.7 6.1 (max