Краткое содержание страницы № 1
Cat.No. W303–E1–4
Programmable Controllers
C200HX/C200HG/C200HE
OPERATION MANUAL
Краткое содержание страницы № 2
C200HX/C200HG/C200HE Programmable Controllers Operation Manual Revised June 2000
Краткое содержание страницы № 3
Notice: OMRON products are manufactured for use according to proper procedures by a qualified operator and only for the purposes described in this manual. The following conventions are used to indicate and classify precautions in this manual. Always heed the information provided with them. Failure to heed precautions can result in injury to people or dam- age to property. ! DANGER Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. ! WARNING
Краткое содержание страницы № 4
TABLE OF CONTENTS PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiii 1 Intended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiv 2 General Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiv 3 Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Краткое содержание страницы № 5
TABLE OF CONTENTS 4-8 Controlling Bit Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 4-9 Work Bits (Internal Relays) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122 4-10 Programming Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124 4-11 Program Execution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Краткое содержание страницы № 6
TABLE OF CONTENTS SECTION 8 Serial Communications . . . . . . . . . . . . . . . . . . . . . . . . . . . 417 8-1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 418 8-2 Host Link Communications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 419 8-3 RS-232C Communications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Краткое содержание страницы № 7
About this Manual: This manual describes the operation of the C200HX/HG/HE Programmable Controllers, and it includes the sections described below. Installation information is provided in the C200HX/HG/HE Programmable Controller Installation Guide. A table of other manuals that can be used in conjunction with this manual is provided in Section 1 Introduction. Provided in Section 2 Hardware Considerations is a description of the differences between the C200HS CPU Units and the new CPU Units descri
Краткое содержание страницы № 8
PRECAUTIONS This section provides general precautions for using the Programmable Controller (PC) and related devices. The information contained in this section is important for the safe and reliable application of the PC. You must read this section and understand the information contained before attempting to set up or operate a PC system. 1 Intended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiv 2 General Precau
Краткое содержание страницы № 9
Safety Precautions 3 1 Intended Audience This manual is intended for the following personnel, who must also have knowl- edge of electrical systems (an electrical engineer or the equivalent). • Personnel in charge of installing FA systems. • Personnel in charge of designing FA systems. • Personnel in charge of managing FA systems and facilities. 2 General Precautions The user must operate the product according to the performance specifications described in the operation manuals. Before using the
Краткое содержание страницы № 10
Application Precautions 5 such problems, external safety measures must be provided to ensure safety in the system. • When the 24-VDC output (service power supply to the PC) is overloaded or short-circuited, the voltage may drop and result in the outputs being turned OFF. As a countermeasure for such problems, external safety measures must be provided to ensure safety in the system. Caution Execute online edit only after confirming that no adverse effects will be caused ! by extending the cycle t
Краткое содержание страницы № 11
Application Precautions 5 • Connecting or disconnecting any cables or wiring. ! Caution Failure to abide by the following precautions could lead to faulty operation of the PC or the system or could damage the PC or PC Units. Always heed these pre- cautions. • Use the Units only with the power supplies and voltages specified in the opera- tion manuals. Other power supplies and voltages may damage the Units. • Take measures to stabilize the power supply to conform to the rated supply if it is not
Краткое содержание страницы № 12
Conformance to EC Directives 6 6 Conformance to EC Directives Observe the following precautions when installing the C200HX/HG/HE PCs that conform to the EC Directives. Provide reinforced insulation or double insulation for the DC power source con- nected to the DC I/O Unit and for the Power Supply Unit. Use a separate power source for the DC I/O Unit from the external power supply for the Relay Output Unit. xvii
Краткое содержание страницы № 13
SECTION 1 Introduction This section gives a brief overview of the history of Programmable Controllers and explains terms commonly used in ladder- diagram programming. It also provides an overview of the process of programming and operating a PC and explains basic terminology used with OMRON PCs. Descriptions of peripheral devices used with the C200HX/HG/HE PCs, a table of other manuals available to use with this manual for special PC applications, and a description of the new features of the C20
Краткое содержание страницы № 14
The Origins of PC Logic Section 1-2 1-1 Overview A PC (Programmable Controller) is basically a CPU (Central Processing Unit) containing a program and connected to input and output (I/O) devices. The pro- gram controls the PC so that when an input signal from an input device turns ON, the appropriate response is made. The response normally involves turning ON an output signal to some sort of output device. The input devices could be photo- electric sensors, pushbuttons on control panels, limit sw
Краткое содержание страницы № 15
PC Terminology Section 1-3 Actually there is not a total equivalence between these terms. The term condi- tion is only used to describe ladder diagram programs in general and is specifi- cally equivalent to one of a certain set of basic instructions. The terms input and output are not used in programming per se, except in reference to I/O bits that are assigned to input and output signals coming into and leaving the PC. Nor- mally open conditions and normally closed conditions are explained in 4
Краткое содержание страницы № 16
Overview of PC Operation Section 1-5 1-4 OMRON Product Terminology OMRON products are divided into several functional groups that have generic names. Appendix A Standard Models list products according to these groups. The term Unit is used to refer to all of the OMRON PC products. Although a Unit is any one of the building blocks that goes together to form a C200HX/HG/HE PC, its meaning is generally, but not always, limited in context to refer to the Units that are mounted to a Rack. Most, but n
Краткое содержание страницы № 17
Peripheral Devices Section 1-6 7. Wire the PC to the controlled system. This step can actually be started as soon as step 3 has been completed. Refer to the C200HX/HG/HE PC Instal- lation Guide and to Operation Manuals and System Manuals for details on individual Units. 8. Test the program in an actual control situation and carry out fine tuning as required. (Section 7 Program Monitoring and Execution and Section 9 Trou- bleshooting) 9. Record two copies of the finished program on masters and st
Краткое содержание страницы № 18
Available Manuals Section 1-7 PC programs can be written on-screen in ladder-diagram form as well as in mne- monic form. As the program is written, it is displayed on a display, making con- firmation and modification quick and easy. Syntax checks may also be per- formed on the programs before they are downloaded to the PC. The SSS comes on 3.5” disks. A computer running the SSS is connected to the C200HX/HG/HE PC via the Pe- ripheral Port on the CPU Unit using the CQM1-CIF02 or CV500-CIF01 cable
Краткое содержание страницы № 19
C200HX/HG/HE Features Section 1-8 Name Cat. No. Contents PID Control Unit Operation Manual W241 Information on PID Control Unit Cam Positioner Unit Operation Manual W224 Information on Cam Positioner Unit 1-8 C200HX/HG/HE Features The C200HX/HG/HE CPU Units have a number of new features, but C200H and C200HS programs can be used in the new CPU Units. 1-8-1 C200HS and C200HX/HG/HE Capabilities The following table shows the new capabilities of the C200HX/HG/HE PCs and compares them with those of t
Краткое содержание страницы № 20
C200HX/HG/HE Features Section 1-8 Function Function Capability C200HX/HG/HE C200HS CPU Unit RS-232C port Available in the Available in the functions C200HX/HG/HE-CPU4-E/6-E C200HS-CPU2-E /3-E Clock function Available in all except the C200HE-CPU11-E Available in all models SYSMAC NET Link and Communications Boards can be installed in Available in the SYSMAC LINK functions all PCs except the C200HE-CPU11-E. C200HS-CPU3-E (Board model numbers: C200HW-COM01/04-E) Communications --- Communicati