Краткое содержание страницы № 7
PART A, FIGURE 5 MINIMUM CHIMNEY CLEARANCE TO (FIGURE 5 CONTIUED ON NEXT PAGE) BRICK AND COMBUSTIBLES IS 2 IN. MINIMUM CLEARANCES 12 IN. OF BRICK ALL AROUND CHINEY CONNECTOR TO HEATER FIRE CLAY LINER MINIMUM 12 IN. (5/8" MIN. WALL THICKNESS) TO COMBUSTIBLES MASONRY CHIMNEY MIN. 3-1/2" THICK BRICK CONSTRUCTED TO MASONRY WALL NFPA 211 1. Use a minimum 3-1/2" thick brick masonry wall framed into the combustible wall. A fireclay liner (ASTM C315 or equivalent) having a 5/8" minimum wall thickness m
Краткое содержание страницы № 8
AIR SPACE MINIMUM CHIMNEY CLEARANCES FROM MASONRY TO PART B SHEET STEEL SUPPORTS AND COMBUSTIBLES 2 IN. FIGURE 5 - (FIGURE 5 CONTIN- UED) FACTORY-BUILT MINIMUM CLEARANCE CHIMNEY LENGHT 9 IN. ALL AROUND NONSOLUBLE CHIMNEY CONNECTOR REFACTORY TO HEATER CEMENT CHIMNEY LENGHT FLUSH WITH INSIDE USE CHIMNEY MFRS. PARTS TO OF FLUE AIR SPACE ATTACH CONNECTOR SECURELY 9 IN. MINIMUM SOLID INSULATED, LISTED FACTORY-BUILT CHIMNEY LENGHT MASONRY CHIMNEY CONSTRUCTED SHEET STEEL SUPPORTS TO NFPA 211 (24 GAUGE
Краткое содержание страницы № 9
METAL PREFABRICATED CHIMNEY REQUIREMENTS Any metal prefabricated chimney that this heater is connected to must be a Listed High Temperature Type 103-HT Factory- Built Residential Type and Building Heating Appliance Chimney. Its interior size should be no smaller than 6 inches in diameter or no larger than 8 inches in diameter. An undersized chimney (less than 6 inches interior diameter) will result in poor draft and insufficient operation where as an oversized chimney (larger than 8 inches dia
Краткое содержание страницы № 10
FIGURE 5 - METAL PREFABRICATED CHIMNEY INSTALLED INSIDE THE RESIDENCE THROUGH THE CEILING AND THE ROOF LISTED CHIMNEY INSTALL AN INSULATION SHEILD INSULATION TO MAINTAIN THE SPECIFIED SHEILD CLEARANCE TO INSULATIO. INSU- COMBUSTIBLE SPECIFIED LATION IN THIS AIR SPACE WILL CEILING CLEARANCE CAUSE A HEAT BUILDUP WHICH JOIST MAY IGNITE THE CEILING JOIST. CEILING SUPPORT CHIMNEY CONNECTOR TO HEATER DETAIL OF CONNECTION CHIMNEY CAP (WITH SPARK ARRESTER IF DESIRED OR WHERE REQUIRED BY LAW.) MAINTAIN
Краткое содержание страницы № 11
FIGURE 7 - EXTERIORLY INSTALLED METAL PREFABRICATED CHIMNEY THAT RUNS UP THE OUTSIDE OF THE RESIDENCE. COMBUSTIBLE OUTSIDE WALL 2" CLEARANCE (BETWEEN WALL AND CHIMNEY) LISTED CHIMNEY SECTION LISTED CHIMNEY PIPE TO HEATER INSULATED "T" WALL SUPPORT CHIMNEY CONNECTOR TRIM COLLAR ON INSIDE WALL WALL SPACER ON OUTSIDE WALL DETAIL OF CONNECTION STORM COLLAR CHIMNEY CAP MAINTAIN 2 INCH CLEAR- (WITH SPARK ARRESTER ANCE THROUGH EAVE IF DESIRED OR WHERE REQUIRED BY LAW.) ROOF FLASHING CEILING CHIMNEY INS
Краткое содержание страницы № 12
HEATER INSTALLATION CAUTION: FOR YOUR SAFETY, THE INSTALLATION OF THIS HEATER MUST COMPLY WITH LOCAL CODES AND REGULATIONS. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT INSPECTION TO ASSURE PROPER COMPLIANCE WITH LOCAL CODES AND REGULATIONS. MINIMUM CLEARANCES TO COMBUSTIBLE WALL AND CEILINGS CAUTION: MOST WALLS AND CEILINGS CONTAIN WOOD EVEN THOUGH THEY ARE MADE OF SHEETROCK OR PLASTER ON THE OUTSIDE. THESE WALLS AND CEILINGS CAN CATCH FIRE FROMTHE HOT WATER HEATER OR CHIMNEY CONNECTOR IF
Краткое содержание страницы № 13
Masonry, or other non-combustible products, attached directly to a combustible surface without an air space offer very little protection and cannot be considered a clearance reducer unless specified materials have been tested and listed for direct attachment to a combustible surface. The same applies to thin veneer brick and stone coverings. These materials provide adequate protection only when mounted on sheet metal with a 1 inch spacing to the wall. A variety or prefabricated clearance reduc
Краткое содержание страницы № 14
6. Place the crimped end of the first chimney pipe or elbow into the heater's flue collar and mark it through each of the holes in the heater's flue collar. 7. Remove the pipe or elbow from the flue collar and drill 1/8 - inch diameter holes at the points marked. 8. Apply the furnace to the inside surface of the heater's flue collar, reinstall the first pipe or elbow and fasten in place with No. 8 sheet metal screws. Apply additional furnace cement to the outside of the chimney connector flue
Краткое содержание страницы № 15
OPERATING INSTRUCTIONS Burning Coal in your 4027/ASA7 Your Wondercoal is capable of burning both bituminous and Anthracite coal. Anthracite is the best coal fuel because its long even burn time, high heat output, and cleanliness make it a good choice for the home. However, keep in mind it is a much more difficult fuel to use and requires more care and patience. SIZE OF COAL: Most sizes of bituminous coal will work in your heater; for best results we recommend large nut coal to small egg coal
Краткое содержание страницы № 16
OPERATING INSTRUCTIONS continued... Loading • Coal should never be added unless there is a reasonable hot fire. The coal bed should be bright and vigorous. • If the fire is burning hot and there is a deep bed of coals, full loads of coal can be added at any time. However, if there is not a deep bed of coals, it is best to add small amounts of coal at first. Increasing Heat From a Low Fire • Every effort should be made not to let a coal fire burn too long so that the fire has started to die.
Краткое содержание страницы № 17
OPERATING INSTRUCTIONS continued... Safety • Before opening the loading door, open the pipe damper and the ash door first. • Whenever a loading door is opened, it always should be cracked slightly to allow oxygen to enter and burn any combus- tion gases that are present before fully opening. Failure to do this could result in sudden ignition of the unburned gases when the door is opened. • A stove never should be filled with excessive coal so that the flue gas exit is blocked or impeded in any
Краткое содержание страницы № 18
23 22 21 20 4027 & ASA7 Repair Parts 20 26 25 24 16 15 19 14 17 2 15 18 16 89 3 56 7 4 10 12 11 13 1 18 USSC
Краткое содержание страницы № 19
MODEL 4027 & ASA7 - PARTS LIST KEY PART NO. DESCRITION QTY. 1 40422 Cast Iron Legs 4 • 83507 3/8-16 x 1-1/4 Bolt 4 2 25096 Flue Collar 1 • 83431 Weld Tab 3 • 83045A Washer 3/8 i.d._7/8 o.d. 3 • 83432 5/16-18 x 1-1/2 Hex Bolt 3 3 25080B Door Latch 2 • 83508 5/16- 18 x 3/4 Bolt 2 • 83338 5/16- 18 Lock Nut 2 4 69338B Shaker Handle Assembly 12 * 40423 Complete Shaker Grate Assembly 1 5 83109 1/4-20 Square Nut 2 6 25079 Retainer, Cog 1 7 83227 1/4-20 x 1 Bolt 2 8 40408 Left Shaker Grate 1 9 40409 R
Краткое содержание страницы № 20
HOW TO ORDER REPAIR PARTS THIS MANUAL WILL HELP YOU OBTAIN EFFICIENT, DEPEND- ABLE SERVICE FROM YOUR HOTBLAST FURNACE, AND EN- ABLE YOU TO ORDER REPAIR PARTS CORRECTLY. KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFER- ENCE. WHEN WRITING, ALWAYS GIVE THE FULL MODEL NUMBER WHICH IS ON THE NAMEPLATE ATTACHED TO THE HEATER. WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION AS SHOWN IN THIS LIST: 1. THE PART NUMBER 2. THE PART DESCRIPTION 3. THE MODEL NUMBER: 4027 ASA7 4. THE S
Краткое содержание страницы № 1
E
V
O
T
S
C
S
O
E
M
T
Owner’s
Manual
4027 & ASA7
Free-Standing Coal Heater
This is a COAL ONLY Room Heater
Tested to: UL 1482 and CAN/ULC S627-M93
IMPROPER INSTALLATION MAY VOID
CAUTION:
YOUR WARRANTY
READ ALL INSTRUCTIONS CARE-
FULLY BEFORE STARTING THE
INSTALLATION OR OPERATING DO NOT USE THIS HEATER
THE HEATER IN A MOBILE HOME OR TRAILER
UNITED STATES STOVE COMPANY
227 Industrial Park Road
P.O.Box 151
SC
US
South Pittsburg, TN 37380
C R
US
(423) 837-2100
851523
USSC 1
P
Краткое содержание страницы № 2
SAFETY PRECAUTIONS PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE YOUR NEW HEATING APPLIANCE. FAIL- URE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH. THIS HEATING APPLIANCE SHOULD BE INSTALLED ONLY BY AN EXPERIENCED COAL HEATER INSTALLER. IF THIS HEATING APPLIANCE IS NOT PROPERLY INSTALLED, A HOUSE FIRE MAY RESULT. TO REDUCE THE RISK OF FIRE, FOLLOW THE INSTALLATION INSTRUCTIONS. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND
Краткое содержание страницы № 3
ASSEMBLY Before Assembly, inspect the heater thoroghly for missing parts or shipping damage. If any damage or missing parts are detected, report it to your heater dealer. DO NOT INSTALL OR USE A DAMAGED OR INCOMPLETE HEATER Shaker Handle Assembly: (A) 1. First, remove the two(2) bolts from the left side of the unit where the shaker handle is to be mounted. 2. Next, spin the shaker plate (a) counteclockwise until it stops. Slide the shaker handle through the hole and on to the shaker grate. NOT
Краткое содержание страницы № 4
SELECTING A LOCATION FOR YOUR HEATER 1. When locating the heater , consider safety, convenience, traffic flow, and the fact that the heater will need a chimney,chimney connector,and possibly a floor protector. Make sure none of these materials will be obstructed. 2. The heater should be located away from door ways and central heat outlets to reduce the chances of drafts, blowing smoke, ashes or sparks out of the heater during refueling or ash removal. 3. The heater should be located in an open
Краткое содержание страницы № 5
Ceiling NONCOMBUSTIBLE FIRE-STOPPING MATERIAL FLOOR MINMUM 2 INCH CLEARANCE FOR INTERIOR CHIMNEY. MINIMUM 1 INCH CLEARANCE FOR EXTERIOR CHIMNEY TO SHEATHING CEILING CHIMNEY CAULKING FLOOR FIGURE 2- (SECOND STORY) MASONRY CHIMNEY REQUIREMENTS Minimum 2 Inch Clearance From Combustible Material and Insulation Noncombustible Fire-Stopping Material FIGURE 3- MASONRY CHIMNEY REQUIREMENTS FIGURE 4- CHIMNEY HEIGHT REQUIREMENTS A Chimney must be the required height above the roof or other obstruction for
Краткое содержание страницы № 6
CONNECTION OF CHIMNEY TO A MASONRY CHIMNEY THROUGH A COMBUSTIBLE WALL Figure 5 shows how to connect the chimney connector of a heater to a masonry chimney through a combustible wall. There are five allowable ways that a chimney connector can be connected to a masonry chimney by passing through a combustible wall. NFPA Standard 211 allows the following wall pass-through systems. FIGURE 5 - CONNECTION OF CHIMNEY CONNECTOR TO A MASONRY CHIMNEY THROUGH A COMBUSTIBLE WALL CEILING SEE PARTS A, B, C,