Краткое содержание страницы № 1
TECHNICAL USER MANUAL FOR:
smartCore Express
SMA200
Nordstrasse 11/F
CH - 4542 Luterbach
Tel.: ++41 (0)32 681 58 00
Fax: ++41 (0)32 681 58 01
Email: support@digitallogic.com
Homepage: http://www.digitallogic.com
Краткое содержание страницы № 2
DIGITAL-LOGIC AG SMA200 Manual V1.0 For internal use only: File: SMA200_TechManual_V1.0.doc Path: R:\HANDBUCH\smart\SMA200\SMA200_TechManual_V1.0.doc COPYRIGHT 2008 BY DIGITAL-LOGIC AG This publication is protected by copyright and all rights are reserved. No part of this document may be reproduced, transmitted, transcribed or stored in a retrieval system, in any form or by any means, electronic, mechanical, optical, manual, or otherwise, without the prior written permissio
Краткое содержание страницы № 3
DIGITAL-LOGIC AG SMA200 Manual V1.0 Table of Contents 1. PREFACE.....................................................................................................................................................4 1.1. Trademarks ..................................................................................................................................... 4 1.2. Disclaimer ..............................................................................................................
Краткое содержание страницы № 4
DIGITAL-LOGIC AG SMA200 Manual V1.0 1. PREFACE The information contained in this manual has been carefully checked and is believed to be accurate; it is subject to change without notice. Product advances mean that some specifications may have changed. DIGITAL-LOGIC AG assumes no responsibility for any inaccuracies, or the consequences thereof, that may appear in this manual. Furthermore, DIGITAL-LOGIC AG does not accept any liability arising from the use or application of any circuit or
Краткое содержание страницы № 5
DIGITAL-LOGIC AG SMA200 Manual V1.0 1.5. Recycling Information All components within this product fulfill the requirements of the RoHS (Restriction of Hazardous Substances Directive). The product is soldered with a lead free process. 1.6. Technical Support 1. Contact your local DIGITAL-LOGIC Technical Support, in your country. 2. Use the Internet Support Request form at http://support.digitallogic.ch/ embedded products New Support Request Support requests are only accepted wit
Краткое содержание страницы № 6
DIGITAL-LOGIC AG SMA200 Manual V1.0 1.8. Explanation of Symbols CE Conformity This symbol indicates that the product described in this manual is in compliance with all applied CE standards. Caution, Electric Shock! This symbol and title warn of hazards due to electrical shocks (> 60V) when touching products or parts of them. Failure to observe the precautions indicated and/or prescribed by the law may endanger your life/health and/or result in damage to your equipment. Cautio
Краткое содержание страницы № 7
DIGITAL-LOGIC AG SMA200 Manual V1.0 1.9. Applicable Documents and Standards The following publications are used in conjunction with this manual. When any of the referenced specifications are superseded by an approved revision, that revision shall apply. All documents may be obtained from their respective organizations. Advanced Configuration and Power Interface Specification Revision 2.0c, August 25, 2003 Copyright © 1996-2003 Compaq Computer Corporation, Intel Corporation, Microsoft
Краткое содержание страницы № 8
DIGITAL-LOGIC AG SMA200 Manual V1.0 Smart Battery Data Specification Revision 1.1, December 11, 1998. www.sbs-forum.org System Management Bus (SMBus) Specification Version 2.0, August 3, 2000 Copyright © 1994, 1995, 1998, 2000 Duracell, Inc., Energizer Power Systems, Inc., Fujitsu, Ltd., Intel Corporation, Linear Technology Inc., Maxim Integrated Products, Mitsubishi Electric Semiconductor Company, Power- Smart, Inc., Toshiba Battery Co. Ltd., Unitrode Corporation, USAR Systems, Inc.
Краткое содержание страницы № 9
DIGITAL-LOGIC AG SMA200 Manual V1.0 RoHS is often referred to as the "lead-free" directive but it restricts the use of the following substances: Lead Mercury Cadmium Chromium VI PBB and PBDE The maximum allowable concentration of any of the above mentioned substances is 0.1% (except for Cadmium, which is limited to 0.01%) by weight of homogeneous material. This means that the limits do not apply to the weight of the finished product, or even to a component but to any single
Краткое содержание страницы № 10
DIGITAL-LOGIC AG SMA200 Manual V1.0 1.12. Swiss Quality 100% Made in Switzerland DIGITAL-LOGIC is a member of "Swiss-Label" This product was not manufactured by employees earning piecework wages This product was manufactured in humane work conditions All employees who worked on this product are paid customary Swiss market wages and are insured ISO 9000:2001 (quality management system) 1.13. The Swiss Association for Quality and Management Systems The Swiss Association
Краткое содержание страницы № 11
DIGITAL-LOGIC AG SMA200 Manual V1.0 2. OVERVIEW 2.1. Standard Features The smartCoreExpress is an electrical and mechanical definition for a COM or Computer on Module (miniaturized PC system), based on Intel's ATOM chip unit incorporating the major elements of a PC compatible computer. Powerful though low consumption ATOM CPU Soldered DDR2 RAM 512k up to 2GByte Single 220pin connectors (Tyco) for the smartCoreExpress BUS 5x x1 PCI-Express lanes 8x USB V2.0 1x PATA or (4
Краткое содержание страницы № 12
DIGITAL-LOGIC AG SMA200 Manual V1.0 2.2. Technical Specifications CPU Specification CoreDuo / Celeron M Intel Atom 510 1.10GHz with 0.5MB L2-cache Intel Atom 530 1.60GHz with 0.5MB L2-cache Clock 1.1 or 1.6GHz st 1 Level Cache 2x 32kByte nd 2 Level Cache 0.54 MByte (on die) Technology 40nm VCCCore @ 1.6GHz 1.050V VCCCore @ 1.1GHz 0.844V VCCCore @ deep sleep 0.748V CPU BUS CMOS AGTL+ Termination Not needed FSB 533MHz quad-pumped synchronous BUS Mathematics Coprocessor Avai
Краткое содержание страницы № 13
DIGITAL-LOGIC AG SMA200 Manual V1.0 Intel US15W Specification PCIe BUS 2x x1 Lane EIDE BUS 1x Ultra P-ATA 100 SATA BUS - USB V2.0 8 channel USB APIC INTEL I/O APIC SMB V2.0 SMBus controller FWH FirmWare Hub for BIOS devices LPC Serialized BUS (no ISA) used for external SuperI/O Sound AC97 2.3 HDA Interface with 192kHz sampling rate and 8 channels IRQ Controller 8259 compatible Timers 8254 compatible Power Management Integrated Reset & Power Management Specification Cont
Краткое содержание страницы № 14
DIGITAL-LOGIC AG SMA200 Manual V1.0 Operating Environment Specification Relative Humidity 5-90% non-condensing Vibration 5 to 2000 Hz Shock 10 G Operating Temperature Standard: t.b.d. (depends on the CPU and the cooling concept) Extended Range: t.b.d. Maximum Copper Temperature 90°C Storage Temperature -55°C to +85°C EMI / EMC (IEC1131-2 refer MIL 461/462) Specification ESD Electro Static Discharge IEC 801-2, EN55101-2, VDE 0843/0847 Part 2 Metallic protection needed Separate
Краткое содержание страницы № 15
SPI BUS LPC BUS HD Audio / AC link SD/SDIO/MMC 2x PCIe 8x USB PAT SVDO / GMBus (I2C) FSB LVDS, Backlight, DDC SMB DIGITAL-LOGIC AG SMA200 Manual V1.0 3. DIMENSIONS & DIAGRAMS 3.1. Block Diagram 1 GB DDR2 RAM Intel Atom System Controller Hub FSB Processor US15W Firmware Hub CPU (BIOS) (power supply) Temp. Sensor Option Power SSD 4GB Management Microcontroller Module Connector (220 pin) 15
Краткое содержание страницы № 16
DIGITAL-LOGIC AG SMA200 Manual V1.0 Design IN with the smartModule Attention! When using an active/passive heatsink that is not from DLAG, be very careful! The maximum depth the screws can go into the product is 3mm or the module will be destroyed! 3.2. Dimensions of the smartCoreExpress Module 65.0mm 58.5mm 3.25 3.25 3.25 View of the bottom side of the smartCoreExpress module. All dimensions with +/-0.1mm tolerance if not otherwise specified. Units = millimeter. 58.
Краткое содержание страницы № 17
DIGITAL-LOGIC AG SMA200 Manual V1.0 3.3. Connector Placement & Pin Definition on the Carrier Board View of the Top Side (mounting side) of the smartCoreExpress PCB: d=2.2/D=4.5 3.25 3.25 smartCoreExpress 44.0mm PCB pad design 58.5mm d=2.2/D=4.5 0.3 1.6 1.6 0.5 50.2mm 0.4 B1 B110 1.8 d=1.0 d=1.6 3.6mm A1 A2 A3 ... A110 57.7mm 17
Краткое содержание страницы № 18
DIGITAL-LOGIC AG SMA200 Manual V1.0 3.4. Photo of the Top Side of the PCB 65mm 58mm Pin 1 18
Краткое содержание страницы № 19
DIGITAL-LOGIC AG SMA200 Manual V1.0 3.5. Dimensions of the Carrier Board Connector SMX-CON8: Standard Height: 5.0mm (Available alternative: 8.0mm) DLAG Part Nr: 807138 AMP/Tyco: 8-6318491-6 (Components placed below the smartModule should total a maximum of 2.0mm.) 3.6. Component Heights between Module and Carrier Board Parts mounted on the back side of the module (in the space between the bottom surface of the module PCB and the carrier board) should have a maximum height of
Краткое содержание страницы № 20
DIGITAL-LOGIC AG SMA200 Manual V1.0 4. COM-EXPRESS CONNECTOR DESCRIPTION 4.1. Signal Terminology Descriptions Signal Description PU Internally implemented pull up resistor PD Internally implemented pull down resistor I/O 3.3V Bi-directional signal 3.3V tolerant I/O 5V Bi-directional signal 5V tolerant I 3V Input 3.3V tolerant I 5V Input 5V tolerant I/O 3.3VSB Input 3.3V tolerant, active in standby state O 3V Output 3.3V signal level O 5V Output 5V signal level P Power input/out