Краткое содержание страницы № 1
14,000 BTU Portable Air Conditioner
14,200 BTU Heat Pump
Model Number: LX-140
Operating Instructions
3092402
Model No. LX-140
V.121031
Краткое содержание страницы № 2
Thank you for choosing a Soleus Air LX-140 Portable Air Conditioner & Heat Pump. This owner’s manual will provide you with valuable information necessary for the proper care and maintenance of your new product. Please take a few moments to thoroughly read the instructions and familiarize yourself with all the operational aspects of your new Soleus Air Portable Air Conditioner with Heat Pump technology. For your own records, please attach a copy of your sales receipt to this manual. Also
Краткое содержание страницы № 3
PACKAGE CONTENTS Portable Air Conditioner Exhaust Hoses (2) Hose Adapters (2) Window Kit Adapter (2) Remote Control AAA Batteries (2) Window Kit - 4 Sliding Panels (1 dual hose panel, 1 single hose panel, 2 extension panels) 81” Length Air Intake and Outlet Covers (2) Owner’s Manual SPECIFICATIONS • The cooling capacity is measured at an ambient temperature of DB 86 °F, WB 78 °F. • Noise level is measured at a distance of 3.28 ft away from the front of the unit, when the unit
Краткое содержание страницы № 4
LCDI POWER CORD AND PLUG This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord with no termination on the load side and a LCDI attachment plug on the line side. The LCDI power cord and plug will remove the supply source via electrical disconnect (circuit trip) if the nominal current leakage between the cord shield and eit
Краткое содержание страницы № 5
PRODUCT DIAGRAM Control Panel Louvers Signal Receptor Casters Filter Compartment Air Intake Cover/Filter 5
Краткое содержание страницы № 6
PARTS & ASSEMBLY PARTS EXHAUST HOSES Window Kit Adapter WINDOW KIT ASSEMBLY & INSTALLATION INSTALLATION When the unit is operating as an air conditioner, heater, or dehumidifier, the unit draws in fresh outdoor air and exhausts hot air (in AC or dehumidifier mode) or cool air (in Heat mode) out of the room to complete the air exchange. When the unit is operating in fan mode, no outdoor air exchange takes place. The window kit and exhaust hose do not need
Краткое содержание страницы № 7
DUAL HOSE WINDOW KIT INSTALLATION - To quickly and efficiently cool a large area. When using with a sliding door, it is recommended to place the air outtake hose above the air intake hose 7
Краткое содержание страницы № 8
Window Kit Assembly 1.Parts: A) 2 Track Screws B) 2 Wing Nuts C1 & C2) 2 Hose Panels, one with Two Exhaust Hose Openings D) 1 Sliding Track Panel 5. Next, take the other Hose Panel (C2) and connect it to Hose Panel (C1) by placing the Sliding Track Panel (D) over the Track Screw (A) on Hose Panel (C2). 2. Assembly: First, take the Track Screws (A) and screw one into each of the small holes found on the Hose Panels (C1 & C2). 6. The Hose Panels (C1 &C2) should now be connected
Краткое содержание страницы № 9
SINGLE HOSE EXHAUST & WINDOW KIT INSTALLATION When you want quick spot cooling, install the LX-140 using the single hose window kit installation. For Single Hose Installation Install only the left exhaust hose over the circular air outlet (this outlet will be on the left side of the unit when you are facing the back of the unit). Cover the right circular air intake using the exhaust intake cover. After installing the hose remove the square air intake cover on the back of the unit and ins
Краткое содержание страницы № 10
CONTROL PANEL, DISPLAY, & OPERATING INSTRUCTIONS CONTROL PANEL & MULTI-COLOR DISPLAY CONTROL PANEL TEMP & TIMER SELECTION POWER BUTTON MODE BUTTON TIMER BUTTONS TEMP SELECT FAN SPEED BUTTON MULTI-COLOR DISPLAY AUTO A/C DEHUM. FAN HEAT TIMER ON TIMER OFF FAN SPEED TEMPERATURE AND TIMER INDICATOR OSCILLATION ON/OFF COMPRESSOR ON/OFF BUCKET FULL SLEEP MODE ON/OFF 10
Краткое содержание страницы № 11
OPERATING INSTRUCTIONS CONTROL PANEL BUTTONS (Refer to the images on page 10) 1) Power On and Off - Press the POWER button once to manually turn the unit on. Press the POWER button once more to turn the unit off. 2) Mode Selection - Press the MODE Button repeatedly to cycle between the different modes: Auto mode, Air Conditioner, Dehumidifier, Fan only, and Heater. 3) Fan Speed Control - Press the FAN SPEED Button to cycle through the different fan speeds: High, Medium, and low. The f
Краткое содержание страницы № 12
NOTE: During hot days, the unit will cool the room most efficiently by setting the temperature at the lowest setting and the fan speed on high. Reducing the length of the exhaust duct, insulating the exhaust hose and window kit, and keeping direct sunlight to a minimum will also improve the cooling efficiency. NOTE: When the unit is running on cooling mode, the exhaust hoses are required and must be vented outside using the supplied window kit. Dehumidifier Mode 1) Install the exhaus
Краткое содержание страницы № 13
Auto Mode 1) Install the exhaust hoses and window kit properly (see pages 7 , 8 & 9 ). 2) Plug the Power Cord into an electrical outlet. 3) Turn on the unit by pressing the POWER button on the control panel. 4) Press the MODE button until the “ ” icon appears on the control panel display. Select the fan speed by pressing the FAN button. ° NOTE: During AUTO mode, the unit operates in Heating mode when the room temperature is below 68 F, ° ° Dehumidifier mode when the room
Краткое содержание страницы № 14
Emergency Condensate Holding Tank When the room temperature is low and the indoor humidity is high, the air conditioner may not be able to evaporate some of the moisture fast enough. When this happens, the water will accumulate in an emergency condensate tank inside the unit. Once the emergency condensate tank is full, the unit will automatically shut off and the “ ” will appear on the control panel display. To empty the condensate tank, unscrew the screw plug at the bottom back of the un
Краткое содержание страницы № 15
OPERATING THE UNIT USING THE REMOTE CONTROL REMOTE CONTROL LCD DISPLAY MODE BUTTON POWER BUTTON FAN SPEED TEMP SETTING SWING (LOUVER OSCILLATION) TIMER ON SLEEP BUTTON TIMER OFF MINUTE SELECTER HOUR SELECTER 15
Краткое содержание страницы № 16
REMOTE CONTROL OPERATING INSTRUCTIONS 1) Power On and Off - If the unit is already on, press the POWER (I/O) button on the remote while point- ing the remote away from the unit. This will turn the remote on. If the unit is off, now press the POWER (I/O) button once to manually turn the unit on. Press the Power button once more to turn the unit off. When you press the POWER button the upper right square on the remote control LCD Display will light up. When in Air Conditioner, Heating, and
Краткое содержание страницы № 17
MAINTENANCE Note: Make sure power is off and the power cord is not plugged into an electrical outlet prior to performing any maintenance on the unit. Clean or replace filter - If the air filter is blocked with a dust, the airflow volume may reduce. It is recommended to clean the filter once every two weeks or as needed. 1) Remove the filter from the filter compartment on the back of the unit. 2) Wash the air filter by immersing it gently into warm water with a neutral detergent.
Краткое содержание страницы № 18
WARRANTY One Year Limited Warranty Soleus International Inc. warrants the accompanying Soleus Air LX-140 Portable Air Conditioner with Heat Pump technology to be free of defects in material and workmanship for the applications specified in its operation instruction for a period of ONE (1) year from the date of original retail purchase in the United States. If the unit exhibits a defect in normal use, Soleus International Inc. will, at its option, either repair or replace it, free of