Краткое содержание страницы № 1
05-03-457 A029-OK.PDF
Instruction Manual
P O R T A B L E
Air Conditioner
Model No. WA-1400E Model No. WA-1410E
Model No. WA-1400H Model No. WA-1410H
It is important that you read these
instructions before using your new
purchase and we strongly
recommend that you keep them in a
safe place for future reference.
Краткое содержание страницы № 2
05-03-457 A029-OK.PDF TABLE OF CONTENTS THANK YOU ENERGY SAVING TIPS………..……………………………………………….. 2 SPECIFICATIONS..……………………………………………………………….3 BEFORE USE……….……………………………………………………………. 4 PARTS………..…………………………………………………………………….5 INSTALLATION.…………………………………………………………………...6 MOUNTING OF THE EXHAUST PIPE ………………………………………... 7 INSTALLATION OF THE CARBON FILTER…………………………………... 8 OPERATION ……………………………………………………………………… 9 NOTICE.…………………………………………………………………………..12 DRAINAGE………………………………………………………………………. 13 MAINTENANC
Краткое содержание страницы № 3
05-03-457 A029-OK.PDF THANK YOU Thank you for choosing the portable air conditioner from SPTUSA, a leading brand in indoor air treatment. We would like you to enjoy the many benefits this unit offers, so please take the time to read this manual carefully and take full advantage of the many advanced features that your SPTUSA Air Conditioner offers you. SPTUSA specialize in complete indoor environment control, manufacturing world-class air conditioners, dehumidifiers and air purifiers with
Краткое содержание страницы № 4
05-03-457 A029-OK.PDF SPECIFICATION WA-1400E WA-1400H Model no. WA-1410E WA-1410H Cooling capacity 14000 BTU/hr 14000 BTU/hr 14000 BTU/hr Heating capacity - Power/Ampere 1250W/ 11.0A 1250W/ 11.0A consumption for cooling* Power/Ampere - 1250W/ 11.0A consumption for heating* 3 3 Air volume (max. speed) 580m/h 580m /h Humidity removal capacity 53.9 L/day 53.9 L/day Recommended room size 500sq.ft. 500sq.ft. Power supply 115V/60Hz/1phase Compressor Rotary Refrigerant R-22 Refrigerant load* 6
Краткое содержание страницы № 5
05-03-457 A029-OK.PDF BEFORE USE Important! Transport the unit in an upright position only or leave in upright position for at least 2 hours before use. Keep at least 20 inches away from the wall. (Figure 1 & 4) Always place the unit on an even surface. Make sure the unit is connected to a correctly grounded power supply (refer to the rating label located at the back of the unit). FIG. 1 An opening in a window or wall is required to accommodate the exhaust hose (kit supplied) to e
Краткое содержание страницы № 6
05-03-457 A029-OK.PDF PARTS Front Back FIG. 5 FIG.6 1. Control Panel 5. Air filter 2. Air outlet 6. Air inlet 3. Carrying handle 7. Exhaust air outlet 4. Caster 8. Water stopper / drainage point 9. Cord storage Accessories 10. Inward adaptor - for insertion over hose and connect to back of the air conditioner. 11. Round connector - for insertion over hose and into foam strip (or into hole in the wall/window). 12. Exhaust hose: Length: 14”-60” Diameter: 4.75” 13. Round cap
Краткое содержание страницы № 7
05-03-457 A029-OK.PDF INSTALLATION EXHAUST PIPE INSTALLATION The unit is a portable air conditioner that may be moved from room to room. 1. Using the foam strips / Window installation Used to cover the window gap and can be cut to size if necessary. Foam strips FIG.8 • Attach hose to unit and insert other end through the foam strip. • Attach Round Connector (part 11) by turning clock-wise. • Insert strip into window gap as shown and slide window across so that foam is held securely. Th
Краткое содержание страницы № 8
05-03-457 A029-OK.PDF Mounting of the exhaust pipe • Use only the hose provided. Attach hose to back of unit by connecting the adaptor. • Avoid kinks and sharp bends in the exhaust hose as this will cause expelled moist air to build up and the unit will overheat and shut FIG.11 down. Fig 11 & 12 shows correct position • The hose may be extended from 12 inches to 59 inches but for maximum efficiency use the shortest length possible. FIG.12 FIG.13 WARNING! The length of the exhaust pip
Краткое содержание страницы № 9
05-03-457 A029-OK.PDF Installing the Carbon Filter 1. Remove the filter frame from the unit. 2. Unclip and remove one side of the frame. 3. Remove the active carbon filter from its plastic bag. 4. Insert the active carbon filter into the filter frame. 5. Replace the other half of the frame. 6. Re-insert the filter frame inside the unit. 7. It is recommended to replace the carbon filter every 3 to 6 months. Replacement Filter: FIG. 15 To purchase Replacement Filters for this unit,
Краткое содержание страницы № 10
05-03-457 A029-OK.PDF OPERATION Control panel FIG.17 1. Automatic mode indicator 14. UV-Tio2/Ionizer switch (only for models 2. Cooling mode indicator with UV-Tio2 or Ionizer function) 3. Fan mode indicator 15. Sleep function button 4. Heating mode indicator (for cool & heat 16. “Temperature up” button models only). 17. “Temperature down” button 5. Low ventilation indicator 18. LCD display 6. Medium ventilation indicator 19. ON/OFF (power) button 7
Краткое содержание страницы № 11
05-03-457 A029-OK.PDF Auto Mode When this mode is selected, the unit is preset to the following temperature settings and unit will only start to: Cool when room temperature is higher than 75°F Heat when room temperature is lower than 68°F (WA-1400H &WA-1410H models only) If room temperature is between 68°F and 75°F, unit will stay in Fan mode. Again, when in Auto Mode, the temperature settings cannot be changed. Setting temperature o o The pre-setting temperature of this machine is
Краткое содержание страницы № 12
05-03-457 A029-OK.PDF Setting ventilation speed 1. Press SPEED button to choose the desired ventilation speed: High, Medium or Low. The indicator respective speed will light on at the same time. 2. If the unit is in AUTO mode, it will choose the ventilation speed automatically according to the ambient temperature (the related indicators will light on), at this time, this button is invalid. Setting timer 1. Pressing the TIMER button while unit is operating will set desired operating hours (
Краткое содержание страницы № 13
05-03-457 A029-OK.PDF Regulating air flow direction Adjust louver on the air vent horizontally to control air flow direction. FIG. 19 NOTICE ! The compressor will start approximately 3 minutes after the compressor is turned off (this will help prolong the life of the compressor). After switching the unit off, please wait at least 3 minutes before turning the unit back on. The cooling system will switch off if the room temperature is 1ºF lower than set. The fan, however, keeps working at
Краткое содержание страницы № 14
05-03-457 A029-OK.PDF .DRAINAGE During the process of cooling or heating, some water will be extracted from the air. Most of this water is used to cool the cooling coils and make the unit run more efficiently. This is a feature not found in most other portable air conditioners. If the unit is operated in a VERY HUMID environment, water will start to collect in the built-in water reservoir. When the water tank becomes full, the compressor and fan will stop. The water full indicator (W.F.)
Краткое содержание страницы № 15
05-03-457 A029-OK.PDF Original drain NOTE Extended The drain tube must be at or below the drain tube outlet level. (OD: 3/4in) Water Full (full water) indicator will not FIG.23 function in this mode of drainage. If you wish to extend the water tube, please connect with another tube (outside diameter 3/4"). Special caution for heating function! While using the heating function, please note: 1. Install the exhaust hose to exhaust cool air outdoors. (Please refer to page 6 for inst
Краткое содержание страницы № 16
05-03-457 A029-OK.PDF .MAINTENANCE Always unplug the unit before cleaning and maintenance. Cleaning the Housing Use a soft, damp cloth to wipe the body clean. Never use strong chemicals, oil-based products, detergents, chemically treated cloths or other cleaning solutions. These could possibly damage the cabinet. Cleaning the Filter First remove the black active carbon filter from the frame, tap lightly to remove loose dust and dirt. Use a vacuum cleaner or tap the white filter lightly to r
Краткое содержание страницы № 17
05-03-457 A029-OK.PDF .TROUBLE SHOOTING Is the machine plugged in? Is the main power supply on? Is room temperature within working The unit doesn’t run or only runs in fan temp range? mode Is unit set in Auto mode? Select Cool or Heat mode and set to proper temperature. Is there direct sunlight? Please draw curtains and blinds. Are there too many windows or doors The unit seems to do little open? Are there too many people in the room? Is there something in the room tha
Краткое содержание страницы № 18
05-03-457 A029-OK.PDF .DEFECTIVE NOTICE If this product is defective or not working properly Please DO NOT return to your retail store Please contact us directly with any Service or Technical Assistance Contact us toll free at: 1-800-330-0388 REPLACEMENT FILTERS: To purchase Replacement Filters for this unit, contact SPTUSA at 1-800-330-0388 and request model number WA-1400F. 17
Краткое содержание страницы № 19
05-03-457 A029-OK.PDF Portable Air Conditioner / Heater Your Guarantee If this product is found to be faulty as a result of faulty materials or workmanship within one year from date of purchase, it will be repaired or replaced free of charge. This guarantee is subject to the following terms: SPTUSA, must be notified of the fault. Proof of purchase must be presented to SPTUSA’s nominated representative. The warranty will be void if the product is modified, misused or repaired by an unauthor
Краткое содержание страницы № 20
05-03-457 A029-OK.PDF SAFETY POWER SUPPLY CORD: This Portable Air Conditioner is provided with a Leakage Current Detection and Interruption circuit (LCDI) built into the plug of the power supply cord. This device provides protection to reduce the risk of fire due to arcing faults in the power-supply cord. Each time before using the Portable Air Conditioner, follow the “plug Testing Instructions” given below to ensure that the LCDI circuit is functioning properly. PLUG TESTING INSTRUCTIONS