Краткое содержание страницы № 1
P3AM-4822-12ENZ0
ETERNUS DX80 S2/DX90 S2
Disk storage system
User's Guide -Site Planning-
Краткое содержание страницы № 2
This page is intentionally left blank.
Краткое содержание страницы № 3
Preface Fujitsu would like to thank you for purchasing our ETERNUS DX80 S2/DX90 S2 Disk storage system. The ETERNUS DX80 S2/DX90 S2 Disk storage system is designed to be connected to Fujitsu (PRIMEQUEST or PRIMERGY) or non-Fujitsu servers. This manual describes the environmental requirements that are necessary to install and use the ETERNUS DX80 S2/DX90 S2 Disk storage system. This manual is intended for use of ETERNUS DX80 S2/DX90 S2 Disk storage system in regions other than Japan. Please caref
Краткое содержание страницы № 4
About this Manual Organization This manual is composed of the following four chapters: ● Chapter 1 Hardware Configurations This chapter describes the main components and the relative optional products that are installed in the ETERNUS DX80 S2/DX90 S2 Disk storage system. ● Chapter 2 ETERNUS DX Disk Storage System Installation This chapter describes the installation specifications, the installation environment, and the power requirements. ● Chapter 3 Connections This chapter describes the
Краткое содержание страницы № 5
About this Manual Warning Notations Warning signs are shown throughout this manual in order to prevent injury to the user and/or material damage. These signs are composed of a symbol and a message describing the recommended level of caution. The following explains the symbol, its level of caution, and its meaning as used in this manual. This symbol indicates the possibility of minor or moderate personal injury, as well CAUTION as damage to the ETERNUS DX Disk storage system and/or to other user
Краткое содержание страницы № 6
Table of Contents Chapter 1 Hardware Configurations 11 1.1 Controller Enclosure .......................................................................................................... 11 1.1.1 Controllers ..................................................................................................................................................... 15 1.1.2 Power Supply Units ..................................................................................................................
Краткое содержание страницы № 7
Table of Contents Chapter 3 Connections 46 3.1 Host Connections .............................................................................................................. 46 3.1.1 Host Interfaces .............................................................................................................................................. 46 3.1.2 Host Connection Path ...............................................................................................................................
Краткое содержание страницы № 8
List of Figures Figure 1.1 Front view of a 2.5" type controller enclosure.............................................................................................. 11 Figure 1.2 Rear view of a 2.5" type controller enclosure (single-controller type).......................................................... 12 Figure 1.3 Rear view of a 2.5" type controller enclosure (dual-controller type) ............................................................ 12 Figure 1.4 Top view of a 2.5" type control
Краткое содержание страницы № 9
List of Figures Figure 3.11 iSCSI connection for remote copy (using lines)............................................................................................ 53 Figure 3.12 Example of a LAN connection...................................................................................................................... 55 Figure 3.13 Dual-line power supply when connecting to power sockets......................................................................... 57 Figure 3.14 Dual-line pow
Краткое содержание страницы № 10
List of Tables Table 1.1 Host interface specifications........................................................................................................................ 16 Table 1.2 Drive interface port specifications for controllers......................................................................................... 16 Table 1.3 LAN port specifications for controllers ......................................................................................................... 17 Table 1.4
Краткое содержание страницы № 11
Chapter 1 Hardware Configurations This chapter explains hardware configurations for the ETERNUS DX Disk storage system. 1.1 Controller Enclosure This section explains the main components in the controller enclosure. The controller enclosure contains drives installed in the front, and controllers and power supply units in the rear. Since the power supply units are redundant, operations can continue even if one of them fails. There are two models: a single-controller type and a dual-controller ty
Краткое содержание страницы № 12
Chapter 1 Hardware Configurations 1.1 Controller Enclosure ● Rear view • Single-controller type Figure 1.2 Rear view of a 2.5" type controller enclosure (single-controller type) Host interface (CA#1) LAN (RMT) port LAN (MNT) port Controller (CM#0) Cover PWC port Power supply unit (PSU#0) Power supply unit (PSU#1) Drive interface (OUT) port Host interface (CA#0) • Dual-controller type Figure 1.3 Rear view of a 2.5" type controller enclosure (dual-controller type) Host interface (CA#1) Hos
Краткое содержание страницы № 13
Chapter 1 Hardware Configurations 1.1 Controller Enclosure ● Top view Figure 1.4 Top view of a 2.5" type controller enclosure ● Side view Figure 1.5 Side view of a 2.5" type controller enclosure ■ External views of a 3.5" type controller enclosure ● Front view Figure 1.6 Front view of a 3.5" type controller enclosure 3.5" disk or 3.5" Solid State Drive (SSD) 13 ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning- Copyright 2013 FUJITSU LIMITED P3AM-4822-12ENZ0
Краткое содержание страницы № 14
Chapter 1 Hardware Configurations 1.1 Controller Enclosure ● Rear view • Single-controller type Figure 1.7 Rear view of a 3.5" type controller enclosure (single-controller type) Host interface (CA#1) LAN (RMT) port LAN (MNT) port Controller (CM#0) Cover PWC port Power supply unit (PSU#0) Power supply unit (PSU#1) Drive interface (OUT) port Host interface (CA#0) • Dual-controller type Figure 1.8 Rear view of a 3.5" type controller enclosure (dual-controller type) Host interface (CA#1) Hos
Краткое содержание страницы № 15
Chapter 1 Hardware Configurations 1.1 Controller Enclosure ● Top view Figure 1.9 Top view of a 3.5" type controller enclosure ● Side view Figure 1.10 Side view of a 3.5" type controller enclosure 1.1.1 Controllers The controller contains a CPU, cache memory, System Capacitor Unit (SCU), non-volatile memory, host interfaces, drive interface ports, and LAN ports. The controller controls all operations in the ETERNUS DX Disk storage system. ■ CPU A single core processor is installed. ■ Cach
Краткое содержание страницы № 16
Chapter 1 Hardware Configurations 1.1 Controller Enclosure ■ Host interfaces A host interface (CA) is a board that has interface ports to connect a controller to a server. Up to two host interfaces can be installed in the controller of an ETERNUS DX Disk storage system. Different types of host interfaces can exist together in the same controller. For details about the installation rules, refer to "4.3.1 Host Interfaces" (page 70). FC, iSCSI, FCoE, and SAS are available as host interface. The
Краткое содержание страницы № 17
Chapter 1 Hardware Configurations 1.1 Controller Enclosure ■ LAN ports Two LAN ports (RJ-45) are installed in each controller. Each LAN port is used for operation management (MNT port) and for remote support function (RMT port) respectively. The following table shows the LAN port specifications. Table 1.3 LAN port specifications for controllers Transfer speed Number of ports Interface Connector type (max.) for each controller Ethernet 1Gbit/s RJ-45 2 (1000Base-T/100Base-TX/10Base-T) ■ SC
Краткое содержание страницы № 18
Chapter 1 Hardware Configurations 1.2 Drive Enclosures 1.2 Drive Enclosures This section explains the main components in the drive enclosure. The drive enclosure contains drives installed in the front, and I/O modules and power supply units in the rear. Up to 24 drives can be installed in a 2.5" type drive enclosure. Up to 12 drives can be installed in a 3.5" type drive enclosure. Since the power supply units are redundant, operations can continue even if one of them fails. When a drive encl
Краткое содержание страницы № 19
Chapter 1 Hardware Configurations 1.2 Drive Enclosures • Dual-IOM type Figure 1.13 Rear view of a drive enclosure (dual-IOM type) Drive interface (OUT) port Drive interface (OUT) port Drive interface (IN) port Drive interface (IN) port I/O module (IOM6#0) I/O module (IOM6#1) Power supply unit (PSU#1) Power supply unit (PSU#0) ● Top view Figure 1.14 Top view of a 2.5" type drive enclosure ● Side view Figure 1.15 Side view of a 2.5" type drive enclosure 19 ETERNUS DX80 S2/DX90 S2 Disk st
Краткое содержание страницы № 20
Chapter 1 Hardware Configurations 1.2 Drive Enclosures ■ External views of a 3.5" type drive enclosure ● Front view Figure 1.16 Front view of a 3.5" type drive enclosure 3.5" disk or 3.5" Solid State Drive (SSD) DE-ID display panel ● Rear view • Single-IOM type Figure 1.17 Rear view of a drive enclosure (single-IOM type) Drive interface (OUT) port Drive interface (IN) port I/O module (IOM6#0) Cover Power supply unit (PSU#1) Power supply unit (PSU#0) • Dual-IOM type Figure 1.18 Rear vie