Краткое содержание страницы № 1 
                    
                        Dell™ PowerEdge™ 2500 Systems Installation and Troubleshooting Guide 
Introduction 
Indicators, Messages, and Codes 
Finding Software Solutions 
Running the Dell™ Diagnostics 
Troubleshooting Your System 
Installing System Board Options 
Installing Drives 
Getting Help 
Jumpers and Connectors 
Abbreviations and Acronyms 
Figures 
Tables 
Notes, Notices, Cautions, and Warnings 
NOTE: A NOTE indicates important information that helps you make better use of your computer.
 
NOTICE: A NOTICE indicat
                    
                    Краткое содержание страницы № 2 
                    
                        Back to Contents Page  Jumpers and Connectors  Dell™ PowerEdge™ 2500 Systems Installation and Troubleshooting Guide    Jumpers—A General Explanation    System Board Jumpers    System Board Connectors    SCSI Backplane Board Connectors    Interposer Board Connectors    Disabling a Forgotten Password  This section provides specific information about the jumpers on the system board. It also provides some basic information on jumpers and switches and describes the  connectors and sockets on the vari
                    
                    Краткое содержание страницы № 3 
                    
                             Table A-1. System-Board Jumper Settings        Jumper Setting Description  PASSWD (default) The password feature is enabled.  The password feature is disabled.    NVRAM_CLR (default) The configuration settings are retained at system boot.  The configuration settings are cleared at next system boot. (If the configuration settings become corrupted to the point where    the system will not boot, install the jumper plug and boot the system. Remove the jumper before restoring the configuration  
                    
                    Краткое содержание страницы № 4 
                    
                             Interposer Board Connectors  Figure A-4 shows the connectors and sockets located on the interposer board.   Figure A-4. Connectors on the Interposer Board          Disabling a Forgotten Password  The computer's software security features include a system password and a setup password, which are discussed in detail in Section 4, "Using the System Setup  Program," in the User's Guide. A password jumper on the system board enables these password features or disables them and clears any passwor
                    
                    Краткое содержание страницы № 5 
                    
                        NOTE: If you assign a new system and/or setup password with the jumper plug still removed, the system disables the new password(s) the next time it  boots. 6.  Repeat step 1.    7.  Install the jumper plug on the PASSWD jumper.    8.  Replace the right-side computer cover, and then reconnect the computer and peripherals to their electrical outlets and turn them on.    9.  Assign a new system and/or setup password.    To assign a new system password using the System Setup program, see "Assigning 
                    
                    Краткое содержание страницы № 6 
                    
                        Back to Contents Page  Abbreviations and Acronyms  Dell™ PowerEdge™ 2500 Systems Installation and Troubleshooting Guide  The following list defines or identifies technical terms, abbreviations, and acronyms used in Dell user documents.  NOTE: Unless otherwise specified, these definitions may not apply to operating systems other than Microsoft® Windows® 95 and Windows NT®.  A  ampere(s)  AC  alternating current  ACPI  Advanced Configuration and Power Interface  ADC  analog-to-digital converter  A
                    
                    Краткое содержание страницы № 7 
                    
                        C  Celsius  CCFT  cold cathode fluorescent tube  CD  compact disc  CD-ROM  compact disc read-only memory  CGA  color graphics adapter  cm  centimeter(s)  CMOS   complementary metal-oxide semiconductor  C.O.D.  collect on delivery  cpi  characters per inch  cpl  characters per line  CPU  central processing unit  DAC  digital-to-analog converter  DASH  Dell Advanced SCSI Host  DAT  digital audio tape  dB  decibel(s)  dBA  adjusted decibel(s)  DC  direct current  DIMM  dual in-line memory module  D
                    
                    Краткое содержание страницы № 8 
                    
                        Deutsche Industrie Norm  DIP  dual in-line package  DMA  direct memory access  DOC  Department of Communications (in Canada)  dpi  dots per inch  DRAC  Dell OpenManage™ Remote Assistant Card  DRAM  dynamic random-access memory  DS/DD  double-sided double-density  DS/HD  double-sided high-density  DSA  Dell SCSI Array  ECC  error checking and correction  EDO  extended-data out  EGA  enhanced graphics adapter  EIDE  enhanced integrated drive electronics  EMI  electromagnetic interference  EMM  exp
                    
                    Краткое содержание страницы № 9 
                    
                        electrostatic discharge  ESDI  enhanced small-device interface  ESM  embedded server management  F  Fahrenheit  FAT  file allocation table  FCC  Federal Communications Commission  FIFO  first-in first-out  ft  feet  g  gram(s)  G  gravities  GB  gigabyte(s)  GUI  graphical user interface  h  hexadecimal  HIP  Hardware Instrumentation Package  HMA  high memory area  HPFS  High Performance File System  Hz  hertz  I/O  input/output  ICBM  inter-chassis management bus  ID                            
                    
                    Краткое содержание страницы № 10 
                    
                        identification  IDE  integrated drive electronics  IRQ  interrupt request  ISA  Industry-Standard Architecture  JEIDA   Japanese Electronic Industry Development Association  K  kilo- (1024)  KB  kilobyte(s)  KB/sec  kilobyte(s) per second  Kb  kilobit(s)  Kbps  kilobit(s) per second  kg  kilogram(s)  kHz  kilohertz  LAN  local area network  lb  pound(s)  LCD  liquid crystal display  LED  light-emitting diode  LIF  low insertion force  LN  load number  lpi  lines per inch                         
                    
                    Краткое содержание страницы № 11 
                    
                        LVD  low voltage differential  m  meter(s)  mA  milliampere(s)  mAh  milliampere-hour(s)  MB  megabyte(s)  Mb  megabit(s)  Mbps  megabit(s) per second  MBR  master boot record  MDA  monochrome display adapter  MGA  monochrome graphics adapter  MHz  megahertz  MMX™  MultiMedia eXtensions  mm  millimeter(s)  ms  millisecond(s)  MS-DOS®  Microsoft Disk Operating System  MTBF  mean time between failures  mV  millivolt(s)  NIC  network interface controller  NiCad  nickel cadmium                      
                    
                    Краткое содержание страницы № 12 
                    
                        NiMH  nickel-metal hydride  NMI  nonmaskable interrupt  NNM  Network Node Manager  ns  nanosecond(s)  NTFS  NT File System  NVRAM  nonvolatile random-access memory  OS/2®  Operating System/2  OTP  one-time programmable  PAL  programmable array logic  PCI   Peripheral Component Interconnect  PCMCIA  Personal Computer Memory Card International Association  PGA  pin grid array  POST  power-on self-test  ppm  pages per minute  PQFP  plastic quad flat pack  PSDB  power-supply distribution board  PS/2
                    
                    Краткое содержание страницы № 13 
                    
                        RAID  redundant arrays of independent disks  RAM  random-access memory  RAMDAC   random-access memory digital-to-analog converter  RCU   Resource Configuration Utility  REN   ringer equivalence number  RFI  radio frequency interference  RGB  red/green/blue  ROM  read-only memory  rpm  revolutions per minute  RTC  real-time clock  SCA  Single Controller Architecture  SCSI  small computer system interface  SDS  Scalable Disk System  sec  second(s)  SEC  single-edge contact  SDRAM  synchronous dyna
                    
                    Краткое содержание страницы № 14 
                    
                        SRAM  static random-access memory  SSU  system setup utility  SVGA  super video graphics array  TFT  thin film transistor  tpi  tracks per inch  TSR  terminate-and-stay-resident  UMB  upper memory block  UPS  uninterruptible power supply  USOC  Universal Service Ordering Code  V  volt(s)  VAC  volt(s) alternating current  VDC  volt(s) direct current  VESA®  Video Electronics Standards Association  VGA  video graphics array  VLSI  very-large-scale integration  VRAM  video random-access memory  VR
                    
                    Краткое содержание страницы № 15 
                    
                        watt-hour(s)  X  XMM  extended memory manager  XMS  eXtended Memory Specification  Z  ZIF  zero insertion force  Back to Contents Page                                                                                                                                                                                                                                                                                                                                                                              
                    
                    Краткое содержание страницы № 16 
                    
                        Back to Contents Page  Introduction   Dell™ PowerEdge™ 2500 Systems Installation and Troubleshooting Guide    Other Documents You May Need    Getting Help    Safety, Regulatory, and Warranty Information  Dell™ PowerEdge™ 2500 systems are high-speed servers that offer significant service and upgrade features. These systems include the following service features to  make troubleshooting and repair easy and effective:  l Embedded server management hardware, which monitors temperatures and voltages 
                    
                    Краткое содержание страницы № 17 
                    
                        Back to Contents Page                                                                                                                                                                                                                                                                                                                                                                                                                                                                                               
                    
                    Краткое содержание страницы № 18 
                    
                        Back to Contents Page  Indicators, Messages, and Codes   Dell™ PowerEdge™ 2500 Systems Installation and Troubleshooting Guide    Bezel Indicators   System Messages    Front-Panel Indicators and Features   System Beep Codes    Back-Panel Features   Warning Messages    SCSI Hard-Disk Drive Indicator Codes   Diagnostics Messages    Redundant Power Supply Features   Alert Log Messages From the Dell OpenManage Server Agent  Applications, operating systems, and the system itself are capable of identif
                    
                    Краткое содержание страницы № 19 
                    
                          Back-Panel Features  Figure 2-3 shows the back-panel features of the non-redundant AC power version of the system.   Figure 2-3. Back-Panel Features    SCSI Hard-Disk Drive Indicator Codes  If you have the integrated RAID controller activated, or an optional PERC 3/Di controller is installed in the system, three indicators on each of the hard-disk drive  carriers provide information on the status of the SCSI hard-disk drives (see Table 2-1). The SCSI backplane firmware controls the drive onlin
                    
                    Краткое содержание страницы № 20 
                    
                          Table 2-1 lists the drive indicator patterns established by the SCSI backplane firmware. Different patterns are displayed as drive events occur in the system. For  example, in the event of a hard-disk drive failure, the "drive failed" pattern appears. After the drive is selected for removal, the "drive being prepared for removal"  pattern appears, followed by the "drive ready for insertion or removal" pattern. After the replacement drive is installed, the "drive being prepared for operation" p