Краткое содержание страницы № 1
CheetahSwitch Workgroup-4508
Management Guide
Краткое содержание страницы № 2
Management Guide CheetaSwitch Workgroup-4508 Intelligent Gigabit Ethernet Switch with 8 1000BASE-SX (SC) Ports
Краткое содержание страницы № 3
Copyright © 2000 by Accton Technology Corporation. All rights reserved. No part of this document may be copied or reproduced in any form or by any means without the prior written consent of Accton Technology Corporation. Accton makes no warranties with respect to this documentation and disclaims any implied warranties of merchantability, quality, or fitness for any particular purpose. The information in this document is subject to change without notice. Accton reserves the right to make revis
Краткое содержание страницы № 4
Краткое содержание страницы № 5
Contents Chapter 1: Managing the Switch 1-1 Configuration Options 1-1 Making Connections for System Configuration 1-2 Onsite Connection 1-2 Modem Connection 1-2 Telnet Connection 1-3 In-Band Network Connection 1-3 Chapter 2: Using the System Configuration Program 2-1 Main Menu 2-2 System Information Menu 2-4 Displaying System Information 2-4 Displaying Version Information 2-5 Management Setup Menu 2-5 Changing the Network Configuration 2-6 IP Configuration 2-7 IP Connectivity Test (Ping) 2-8 Acc
Краткое содержание страницы № 6
Configuring Traffic Classes 2-27 Port Priority Configuration 2-27 802.1p Port Traffic Class Information 2-28 Configuring Virtual LANs 2-29 802.1Q VLAN Base Information 2-29 802.1Q VLAN Current Table Information 2-30 802.1Q VLAN Static Table Configuration 2-31 802.1Q VLAN Port Configuration 2-32 Monitoring the Switch 2-33 Displaying Port Statistics 2-34 Displaying RMON Statistics 2-35 Using the Address Table 2-37 Displaying the IP Multicast Registration Table 2-38 Configuring Static Unicast Addre
Краткое содержание страницы № 7
Priority 3-18 Port Priority Configuration 3-18 Port Traffic Class Information 3-19 Configuring VLANs 3-20 VLAN Basic Information 3-20 VLAN Current Table 3-21 VLAN Static List 3-22 VLAN Static Table 3-22 VLAN Static Membership by Port 3-23 VLAN Port Configuration 3-24 IGMP Multicast Filtering 3-25 Configuring IGMP 3-25 IP Multicast Registration Table 3-26 Port Menus 3-26 Port Information 3-26 Port Configuration 3-27 Port Mirroring Configuration 3-28 Port Statistics 3-28 Etherlike Statistics 3-28
Краткое содержание страницы № 8
iv
Краткое содержание страницы № 9
Chapter 1: Managing the Switch Configuration Options The CheetahSwitch Workgroup-4508 provides a menu-driven system configuration program that can be accessed through a direct console connection or modem connection to the serial port on the switch’s rear panel (out-of-band), or by a Telnet connection over the network (in-band). The switch also includes an embedded HTTP Web agent. This Web agent can be accessed using a standard Web browser from any computer attached to the network. The switch’s m
Краткое содержание страницы № 10
CheetahSwitch Workgroup-4508 Making Connections for System Configuration The switch includes a menu-driven configuration program. The ASCII interface to this program can be accessed by making a direct connection to the serial port on the rear panel, or by a Telnet connection to the switch over the network. This section describes how to access the menu-driven configuration program via: • Onsite connection A terminal or workstation connected to the serial port on the rear panel • Modem connection
Краткое содержание страницы № 11
Management Guide Telnet Connection Prior to accessing the switch via an in-band Telnet connection, you must first configure it with a valid IP address, subnet mask, and default gateway using an out-of-band connection or BOOTP protocol. After configuring the switch’s IP parameters, you can access the on-board configuration program from anywhere within the attached network. Note: Up to four Telnet sessions are supported. In-Band Network Connection The on-board configuration program can be accessed
Краткое содержание страницы № 12
CheetahSwitch Workgroup-4508 1-4
Краткое содержание страницы № 13
Chapter 2: Using the System Configuration Program Once a direct connection to the serial port or a Telnet connection is established, the login screen for the on-board configuration program appears as shown below. AAAAAAA AAAAAAAAAA AAAAA AAAA AAAAA AAAA AAAAA AAAA CCCCCCC CCCCCC TTTTTTTTTT OOOOOO NN NN AAAAA AAAA CC CC CC CC TT OO OO NNN NN AAAAA AAAA CC CC
Краткое содержание страницы № 14
CheetahSwitch Workgroup-4508 Main Menu With the system configuration program you can define system parameters, manage the switch and all its ports, or monitor network conditions. The figure below of the Main Menu and the following table briefly describe the selections available from this program. Note: Options for the currently selected item are displayed in the highlighted area at the bottom of the interface screen. CheetahSwitch Workgroup - 4508 Main Menu System Information Menu... Management
Краткое содержание страницы № 15
Management Guide Parameter Description Port Information Displays operational status, including link state, flow control method, speed and duplex mode. Spanning Tree Configuration Enables Spanning Tree Algorithm; also sets parameters for hello time, maximum message age, switch priority, and forward delay; as well as port priority, path cost and Fast STA mode. Spanning Tree Information Displays full listing of parameters for the Spanning Tree Algorithm. Mirror Port Configuration Sets the source an
Краткое содержание страницы № 16
CheetahSwitch Workgroup-4508 System Information Menu Use the System Information Menu to display a basic description of the switch, including contact information, and hardware/firmware versions. CheetahSwitch Workgroup - 4508 System Information Menu System Information ... Switch Information ... Use or arrow keys to move. to select. Displaying System Information Use the System Information screen to display descriptive information about the switch, or for quick system identificat
Краткое содержание страницы № 17
Management Guide Displaying Version Information Use the Switch Information screen to display hardware/firmware version numbers, as well as the power status. CheetahSwitch Workgroup - 4508 Switch Information Hardware Version : V1.0 POST ROM Version : V01.00.00 Firmware Version : V01.00.01 Serial Number : Port Number : 8 Internal Power Status : Redundant Power Status : Use or arrow keys to move. to select. Parameter Description Hardware Version Hardware version of the main board
Краткое содержание страницы № 18
CheetahSwitch Workgroup-4508 CheetahSwitch Workgroup - 4508 Management Setup Network Configuration ... Serial Port Configuration ... SNMP Configuration ... Console Login Configuration ... TFTP Download ... Use or arrow keys to move. to select. Changing the Network Configuration Use the Network Configuration menu to set the bootup option, configure the switch's Internet Protocol (IP) parameters, enable the on-board Web agent, or enable Telnet access. The screen shown below is d
Краткое содержание страницы № 19
Management Guide IP Configuration Use the IP Configuration screen to set the bootup option, or configure the switch's IP parameters. The screen shown below is described in the following table. CheetahSwitch Workgroup - 4508 Network Configuration: IP Configuration Interface Type : Ethernet IP Address : 10.1.113.29 Subnet Mask : 255.255.0.0 Gateway IP : 10.1.0.254 IP State : USER-CONFIG Use or arrow keys to move. other keys to make changes. Parameter Description Interfa
Краткое содержание страницы № 20
CheetahSwitch Workgroup-4508 IP Connectivity Test (Ping) Use the IP Connectivity Test to see if another site on the Internet can be reached. The screen shown below is described in the following table. CheetahSwitch Workgroup - 4508 Network Configuration: IP Connectivity Test (Ping) IP Address : 200.123.211.109 Test Times : 1000 Interval : 1 Success : 1000 Failure : 0 [Start] Use or arrow keys to move. other keys to make changes. Parameter Description IP Address IP address of the site