Краткое содержание страницы № 1
C
N
E
R
G
T
I
INSTALLER / CONSUMER
SAFETY INFORMATION
PLEASE READ THIS MANUAL
BEFORE INSTALLING AND USING
APPLIANCE.
Stardance Direct Vent,
WARNING!
IF THE INFORMATION IN THIS
Rear Vent Gas Heater
MANUAL IS NOT FOLLOWED
Models:
EXACTLY, A FIRE OR EXPLOSION
SDDVR Series: SDDVRCB, SDDVREB, SDDVRMB,
MAY RESULT CAUSING
SDDVRBS, SDDVRCH, SDDVRVG, SDDVRBD
PROPERTY DAMAGE, PERSONAL
SDDVRC Series: SDDVRCCB, SDDVRCEB,
INJURY OR LOSS OF LIFE.
SDDVRCMB, SDDVRCBS, SDDVRCCH, SDDVRCVG,
— Do not s
Краткое содержание страницы № 2
Stardance Direct Vent - Rear Vent Gas Heaters Table of Contents PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a Vermont Castings stove. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty. Installation & General Information .......................................................
Краткое содержание страницы № 3
Stardance Direct Vent - Rear Vent Gas Heaters Installation & Operating Instructions The Stardance Direct Vent Room Heater, Models. SDDVR Series: The Stardance Direct Vent Room Heater, when installed, must SDDVRCB, SDDVREB, SDDVRMB, SDDVRBS, SDDVRCH, SD- be electrically grounded in accordance with local codes or, in the DVRVG, SDDVRBD; SDDVRC Series: SDDVRCCB, SDDVRCEB, absence of local codes, with the National Electrical Code ANSI/ SDDVRCMB, SDDVRCBS, SDDVRCCH, SDDVRCVG, SDDVR- NFPA 70, (late
Краткое содержание страницы № 4
Stardance Direct Vent - Rear Vent Gas Heaters Installation & Operating Instructions Inspection Requirements for the Commonwealth of The state or local gas inspector of the side wall Massachusetts horizontally vented gas fueled equipment shall not All gas fitting and installation of this heater shall only be approve the installation unless, upon inspection, the done by a licensed gas fitter or licensed plumber. inspector observes carbon monoxide detectors and For all side wall horizontally ve
Краткое содержание страницы № 5
Stardance Direct Vent - Rear Vent Gas Heaters Stove Dimensions - Stardance Direct Vent Gas Heater 9" 8" (229 mm) (203 mm) C Valve L Inlet 7 ���” SDDVR Models 8 ���” SDDVRC Models (197 mm) (222 mm) C Flue Centerline L 26 ���" (680 mm) 22 ���” (565 mm) Valve Inlet C L 3" (76 mm) 25���" 14 ���" (368 mm) (654 mm) Fig. 1 Stardance dimensions. 12950 SDDVR dimensions 7/07 djt 20012950 5
Краткое содержание страницы № 6
Stardance Direct Vent - Rear Vent Gas Heaters Installation Requirements The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 - latest edition. (EXCEP- TION: Do not derate this appliance for altitude. Main- A D tain the manifold pressure at 3.5 inches w.c. for Natural Gas, and 10 inches w.c. for Propane). C In Canada, installation must be in accordance with the B current CSA B-149.1 Installation Codes and/or l
Краткое содержание страницы № 7
Stardance Direct Vent - Rear Vent Gas Heaters Parallel Installation: Minimum Clearance Mantel Clearances and Flue Centerline Combustible Mantel or Trim Materials C L 18���" 2���" A (476mm) (63mm) B Noncombustible Materials 3" (75mm) Min. ST382 � " � " A (Max.) B (Min.) (102 mm) (102 mm) ST128a 9” 10 ¹⁄₂” (230 mm) (270 mm) Fig. 3 Parallel installation, minimum back and side clearance. 7 ¹⁄₂” 9” Corner Installation: Minimum Clearance ST128a (190 mm) (230 mm) ST382 6” 7 ¹⁄
Краткое содержание страницы № 8
Stardance Direct Vent - Rear Vent Gas Heaters Gas Specifications Horizontal Termination Max. Min. The vent must rise vertically a minimum of 24” (610mm) Input Input after the first elbow directly off the back of the unit, Model Fuel Gas Control BTU/h BTU/h before the next elbow. The horizontal run may extend SDDVR Series Nat Millivolt 21,000 15,000 up to 20’ (6m) and include a vertical rise of up to 40’ SDDVR Series Prop Millivolt 21,000 16,000 (12m). (Fig. 7) Horizontal termination
Краткое содержание страницы № 9
Stardance Direct Vent - Rear Vent Gas Heaters Vertical Termination Restrictor Plate Adjustment A vertical vent system must terminate no less than 8’ for Extended Pipe Runs (2.44m) and no more than 40’ (12m) above the appli- The Stardance stove is shipped with a restrictor plate ance flue collar. A restrictor plate (supplied) must be in the Parts Bag. Adjustments can be made by loosen- used (where specified) in all vertically terminated vent ing the adjustment screw to allow the restrictor pla
Краткое содержание страницы № 10
Stardance Direct Vent - Rear Vent Gas Heaters Vent Termination Clearances When planning the installation, consider the location Your stove is approved to be vented either through the of the vent terminal and clearances. Some of the most side wall, or vertical through the roof. common clearances to keep in mind are shown in • CFM Corporation does not require any opening Figure 11. for inspection of vent pipe. Important: All vent clearances must be maintained. • Only CFM Corporation venting c
Краткое содержание страницы № 11
V Operable Stardance Direct Vent - Rear Vent Gas Heaters General Venting Information - Termination Location INSIDE CORNER DETAIL G V N H N A D E L C B ����� B V B V ������ V Fixed Operable Closed F V B M V B X J B I K X V A CFM145a AREA WHERE TERMINAL IS NOT PERMITTED V VENT TERMINATION X AIR SUPPLY INLET 1 2 Canadian Installations US Installations CFM145a A = Clearance above grade, veranda, porch, 12” (30cm) 12” (30cm) DV Termin Location deck, or balcony 5/01/01 Rev. 12/05/01 sta B =
Краткое содержание страницы № 12
Stardance Direct Vent - Rear Vent Gas Heaters Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. Inside Corner Alcove Applications* Outside Corner D C C F = Combustible G = 6" (152 mm) Combustible V G 6" (152 mm) Noncombustible V E 2" (51 mm) Noncombustible O V F 2" (51 mm) Balcony - Balcony - with no side wall with perpendicular side wall E = Min. 6” (152 mm) for non-vinyl sidewalls Min. 12” (305 mm) for vinyl sidewalls O =
Краткое содержание страницы № 13
Stardance Direct Vent - Rear Vent Gas Heaters Vertical Termination Kit, 7/12-12/12 Pitch Vent Components 7TDVSKVB The following kits are available to meet the needs of (1) 7/12 - 12/12 Flashing most installations. All pipe has a 7” outer diameter and and all of the other Vertical Termination parts. includes a 4” diameter inner section. A (CG) designa- Vertical Termination, Flat Roof 7DVSKVF tion indicates the part is finished in Charcoal Gray paint. (1) Flat Flashing Consult your de
Краткое содержание страницы № 14
Stardance Direct Vent - Rear Vent Gas Heaters Installation Unpack the Stove The stove is shipped fully assembled on its back. Un- 1/4-20 x 3/8” pack the stove and carefully set it upright. Hex Head Bolt CAUTION Bracket Porcelain enamelled surfaces are fragile. Handle porcelain enamelled castings tenderly. Familiarize Snapstat yourself with the assembly steps before you begin and proceed with deliberation and care. If possible, have assistance available. 1/2” Sheet FK101b Metal Screws Place
Краткое содержание страницы № 15
Stardance Direct Vent - Rear Vent Gas Heaters 2. Locate the vent opening on the wall. Refer to Fig- ures 18 & 19 to determine the top of the opening centerline. It may be necessary to first position the stove and measure to find the hole location. De- pending on whether the wall is made of combustible Rheostat materials, cut the opening to the size shown in Fig- ure 18. Combustible wall openings must be framed as shown in Figure 18. Retaining Nut Vent Opening - Combustible Wall Rheostat Knob
Краткое содержание страницы № 16
Stardance Direct Vent - Rear Vent Gas Heaters 6. Slip the wall plate and trim collar over the interior Inner Flue Collar end of the horizontal pipe and install into the wall sleeve. Seal the joint inside the wall plate if needed to keep cold air from being drawn into the home. Vent Starter Pipe 7. Connect the pipe to the inner collar. Fasten the wall plate to the pipe with three sheet metal screws. Slide Inner the trim collar up against the wall plate to cover the Elbow screws. (Figs. 1
Краткое содержание страницы № 17
Stardance Direct Vent - Rear Vent Gas Heaters Vent Opening - Combustible Wall 9 ³⁄₈" (240mm) 9 ³⁄₈" (240mm) X Vent Opening - Noncombustible Wall 7 ¹⁄₂" (191mm) VO584-100a Fig. 23 Locate vent opening. ST478 Attach the firestop plate to the sleeve end with the Fig. 25 Determine the vertical pipe length. holes. (Fig. 24) NOTE: The wall sleeve is required in combustible walls only. ST214 3. Install the Wall Firestop/Sleeve assembly into the measure vertical vent 12/6/99 djt wall cutout and f
Краткое содержание страницы № 18
Stardance Direct Vent - Rear Vent Gas Heaters NOTE: Be sure to maintain side wall clearances and 10.Install the vent terminal. (Fig. 28) Guide the inner vent run restrictions. Refer to Figures 3 through 11. and outer vent termination collars into the adjacent pipes. Double check that the vent pipes overlap the 1. Establish the vent hole through the wall. collars by 2”. Fasten the termination to the wall with 2. Remove soil to a depth of approximately 16” (400 the screws provided, and caulk
Краткое содержание страницы № 19
Stardance Direct Vent - Rear Vent Gas Heaters 7. Install the appropriate roof support and flashing, Vertical (Through the Roof) making certain that the upper flange of the flashing Vent Assembly base is below the shingles. (Fig. 32) NOTE: All vertically terminated installations must, 8. Install appropriate pipe sections until the vent run where specified, use the restrictor plate, to com- reaches above the flashing. The enlarged ends of ply with Vertical Termination Window (Fig. 8, Page the v
Краткое содержание страницы № 20
Stardance Direct Vent - Rear Vent Gas Heaters • All vegetation within 36” (914 mm) that may interfere with the draft. Fireplace Vent System B NOTE: The collar extending down from the Termina- B tion base is the air intake collar. Use the flex vent liner, B marked with a blue line, to connect between this collar A D and the lower flue collar on the Transition Connector. Also make sure the other flex vent liner is attached to B C the upper Transition Connector collar and the Rain Cap. C (Fig.