Краткое содержание страницы № 1
®
DUAL GPR-DBC
®
WITH SMART FUNNEL
®
SINGLE GPR DBC-DV
®
WITH SMART FUNNEL
Dual Voltage Model
PROGRAMMING MANUAL
BUNN-O-MATIC CORPORATION
POST OFFICE BOX 3227
SPRINGFIELD, ILLINOIS 62708-3227
PHONE: (217) 529-6601 FAX: (217) 529-6644
41343.0000C 10/11 ©2010 Bunn-O-Matic Corporation
CAUTION
!
DISCARD DECANTER
IF:
. CRACKED
. SCRATCHED
. BOILED DRY
. HEATED WHEN EMPTY
. USED ON HIGH FLAME
FUNNEL CONTENTS . OR EXPOSED ELECTRIC
ARE HOT ELEMENTS
FAILURE TO COMPLY RISKS INJURY
Краткое содержание страницы № 2
BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTY Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows: 1) All equipment other than as specified below: 2 years parts and 1 year labor. 2) Electronic circuit and/or control boards: parts and labor for 3 years. 3) Compressors on refrigeration equipment: 5 years parts and 1 year labor. 4) Grinding burrs on coffee grinding equipment to grind coffee to meet original factory screen sieve analysis: parts and labor for 3 years or 30,000 po
Краткое содержание страницы № 3
INTRODUCTION The brewer incorporates a wireless interface system that allows the DBC Grinder to load certain information into the "programming chip" located inside the handle of the funnel. This information includes what flavor of coffee is being ground and what batch size will be brewed (small, medium, or large). Once the correct flavor name and amount of coffee is ground, the funnel is loaded into the brewer. The information from the funnel handle is then transferred into the brewer. The
Краткое содержание страницы № 4
GLOSSARY AD CARD: An assembly consisting of a computer chip (TAG) and an instruction label. Used for loading advertis- ing messages into the brewer. BREW LOCKOUT: The inability to initiate a brew if the water temperature is less than the ready temperature programmed into the brewer. BYPASS: The process of diverting a portion of the brew water to the outside of the paper filter so that it does not pass through the coffee grounds. This process is sometimes used to optimize the flavor of the fin
Краткое содержание страницы № 5
PROGRAMMING Using the menu-driven display on the front of the brewer, the operator has the ability to alter or modify various brewing parameters such as brew temperatures, brew volumes, bypass percentages, etc. This allows for the precise brewing of various flavors of coffee. Programming of the brewer is achieved by entering a certain function. Then, by the use of hidden programming switches, the operator can customize the brewing process to their specifications. PROGRAMMING SWITCHES To
Краткое содержание страницы № 6
DISABLE PROGRAMMING THE BREWER The programming of the brewer is divided into two levels. There is one function in Level 1. All other functions are accessed in Level 2. The following function screens are in order of appearance. Each screen will have instructions on how to access, and the procedures to program the various functions of the brewer. IMPORTANT PROGRAMMING NOTES - READ CAREFULLY - To exit the programming mode at any time, press and release the ON/OFF switch (either on DUAL brewe
Краткое содержание страницы № 7
PROGRAMMING THE BREWER (cont.) RECIPE PROGRAMING METHODS METHOD 2: There are three methods of programming the vari- Using a RECIPE CARD to enter all of the brew set- ous brewing parameters of the SINGLE/GPR DBC or tings at one time: DUAL/GPR DBC with Smart Funnel Brewer. If using a coffee name not in the grinder's memory, the customer can obtain a RECIPE CARD from the METHOD 1: factory with all the information needed to set up that Using a Smart Funnel and a G9-2T DBC or MHG particular co
Краткое содержание страницы № 8
PROGRAMMING FUNCTIONS LEVEL I Press upper right hidden switch for approximately 2 seconds, until the following screen appears. BREW LOCKOUT? NO DONE YES Returns to normal operating mode LEVEL II Press upper right hidden switch for approximately 4 seconds, until “UNITS” appears on screen. Sets unit of Sets unit of Sets warmer Adjusts on UNITS WARMER OFF: OFF WARMER CONTROL? measure to measure to time up to 6 time and heat METRIC DONE ENG (-) DONE (+) NO DONE YES Metric English hours i
Краткое содержание страницы № 9
PROGRAMMING FUNCTIONS (cont.) (A) Sets freshness FRESH TIME: OFF ENABL ENERGYSAVR ? alert up to 4 (-) DONE (+) NO DONE YES hours DUAL SET NEW RECIPE? INSERT FUNNEL BREWERS WITH NEW NAME NO YES SINGLE BREWERS USE LEFT SIDE ONLY (B) QUIT SETUP ? REVIEW RECIPES? YES NO YES (C) NO-NAME SINGLE MODIFY SHOW NEXT BREWERS (C) DUAL SINGLE DUAL BREWERS BREWERS NO-NAME LEFT BREWERS MODIFY SHOW NEXT Continue Cycles thru COPY SETTINGS? to (F) program NO
Краткое содержание страницы № 10
PROGRAMMING FUNCTIONS (cont.) (F) (E) (J) SET ALL FULL 1st ON TIME: X:XX TRANSFER % BYPASS XX SET BY EXAMPLE 3 BATCHES 1/2 (-) DONE (+) COMPLETE (-) DONE (+) NO YES (both sides 1/4 for DUAL brewers) G) ENTER TIMES OFF TIMES: X:XX 3 BATCHES DONE? ENABLE ADS? NO YES (-) DONE (+) NO YES NO DONE YES SET ALL FULL CONTAINER RDY? SET PULSE BREW 3 BATCHES LAST ON: X:XX SET TEMP: 200°F 1/2 QUIT YES NO YES (bot
Краткое содержание страницы № 11
PROGRAMMING FUNCTIONS (cont.) CONTAINER RDY? LEFT BREW VALVE ON NEXT OFF QUIT YES (H) L BYPS OZ/M XX.X SPRAY HEAD CAL? (-) DONE (+) NO YES LEFT BYPASS CALIBRATE SPRAY ON NEXT OFF PRESS BREW START DUAL R BYPS OZ/M XX.X BYPASS CAL? BREWERS (-) DONE (+) NO YES LEFT FUNNEL LOCK SINGLE ON NEXT OFF BREWERS (L) CALIBRATE FLOW? CONTAINER RDY? BREW VALVE NO YES ON NEXT OFF QUIT YES LEFT WARMER ON NEXT OFF BYPASS CALIBRATE BY
Краткое содержание страницы № 12
PROGRAMMING FUNCTIONS - (cont.) UNITS (SETTING UNITS OF MEASURE) 2. Press DONE to proceed. The display should now This function allows the units of measure to be read CHANGING UNITS!! WILL ERASE!! ... ALL set in English or Metric readings for all screens. The PREVIOUSLY STORED RECIPES AND ALL SETUP program is defaulted to English. INFO WILL BE LOST ... ARE YOU SURE?. WARNING: Changing the unit of measure will erase 3. Press YES to begin the change. While the change all coffee recipes stored
Краткое содержание страницы № 13
PROGRAMMING FUNCTIONS - (cont.) AUTO WARMER SHUT OFF (SETTING THE AUTO WARMER CONTROL (SETTING THE HEAT INTENSITY WARMER TO OFF OR A PROGRAMED TIME) AND PROGRAMED TIME) This function allows the warmers on the brewer to This function allows the heat intensity and warm be programed automatically shut off after a set time. time of the warmer(s) on the brewer to be adjusted. When the timer expires the batch lights on that side When the timer expires the batch lights on that side will beg
Краткое содержание страницы № 14
PROGRAMMING THE BREWER (cont.) WARMER CONTROL (SETTING THE HEAT INTENSITY FRESHNESS TIME AND PROGRAMED TIME) (cont.) This function activates a timer to provide a visual indication that the dispensed beverage has 10. Using (-) and (+), set the percent of heat to be reached it's maximum hold time. All batch indicators applied to the warmer. on that side will flash when time expires. 11. When finished, press the center program switch. NOTE: Flashing can be stopped by pressing any The displ
Краткое содержание страницы № 15
PROGRAMMING THE BREWER (cont.) ENABLE ENERGYSAVR This function allows the operator to enable the ENERGY SAVINGS mode function and set the idle time. Once 10. Once the idle time has expired, the display will the set idle time has expired, the operator can choose read either ENERGY SAVER...NO TEMPERATURE to have the heaters either turn off, or reduce the tank or ENERGY SAVER...REDUCED TEMPERATURE, holding temp to 140° F (60° C). depending on the settings. This screen will alternate with PR
Краткое содержание страницы № 16
PROGRAMMING THE BREWER (cont.) SET NEW RECIPE Procedure for Setting the Recipe: Using a Smart Funnel and a G9-2T DBC or MHG NOTE: Before beginning setup, place a server beneath Grinder: the brew funnel (left side on DUAL brewers). This function allows the operator to set BREW 1. Insert the funnel into the grinder and select a batch VOLUMES, BYPASS PERCENTAGES, PULSE BREW size to grind. It is not necessary to have coffee TIMES, and DRIP-OUT TIMES for each coffee name beans in the hopper(s
Краткое содержание страницы № 17
PROGRAMMING THE BREWER (cont.) SET NEW RECIPE (cont.) 8. Using (-) and (+), set the amount of brew water, in proceed with the setup instructions for SETTING ounces, to be dispensed for that particular batch PULSE BREW - ENTER TIMES. SET DRIP TIME. size. (Refer to SET DRIP TIME for description). After 9. When finished, press another batch size and re- SET PULSE BREW has been accomplished, the peat step 8 for that size. Continue setting all batch next function will be SET PREINFUSION. (Ref
Краткое содержание страницы № 18
PROGRAMMING THE BREWER (cont.) SET NEW RECIPE (cont.) being programmed (modified) along with SETUP 24. When finished setting all batch sizes, press DONE. COMPLETE. The display will show the ON and OFF TIMES that 33. After a 5 second delay, the display will advance to were entered for a particular batch size. After a 5 the next coffee name in the brewer's memory. If second delay, the display should read 3 BATCHES no other coffee names are present, the display will DONE. read THAT WAS TH
Краткое содержание страницы № 19
PROGRAMMING THE BREWER (cont.) SET NEW RECIPES (cont.) SET NEW RECIPE: 6. If the brewing information is not correct, or it is Using a RECIPE CARD to load coffee names and desired to exit the setup before the settings are brew settings into the Single/Dual GPR-DBC with loaded into the brewer's memory, press QUIT. The Smart Funnel: display will read (COFFEE NAME) NOT SAVED. The The G9-2T DBC or MHG's memory contains certain display will then return to the MAIN SCREEN. coffee names. If the
Краткое содержание страницы № 20
PROGRAMMING THE BREWER (cont.) SET NEW RECIPES (cont.) SET NEW RECIPE: If not using a Smart Funnel (with a computer chip) and/or a G9-2T DBC or MHG Grinder, the brewer will REVIEW RECIPES? NO YES function as a standard Bunn Single/Dual Brewer: It is possible to operate the brewer without using EXIT TO a Smart Funnel and/or a G9-2T DBC or MHG Grinder. NEXT FUNCTION If a standard funnel, or if a non-DBC grinder is used SCREEN SINGLE DUAL the brewer will automatically