Краткое содержание страницы № 1
®
ELECTRIC BLOWER/VAC
OWNER’S MANUAL
MODELS: BV12200A, BV12200AT
IMPORTANT: Read and understand this manual before assembling or
operating this appliance. Improper use of this appliance can cause severe
injury or death. Keep this manual for future reference.
Double Insulated
Краткое содержание страницы № 2
120133
Краткое содержание страницы № 3
Remington elect Ric blowe R/a v c | iII table of contents 1 Important Safety Information 1 2 Product Identification 3 3 Blower/Vac Assembly 4 Assembling Blower . . . . . . . . . . . . . . . . . . . . . . . 4 . . . . Converting from Blower to Vacuum . . . . . . . . . . . . . . . . .5 . . . 4 Blower/Vac Operation 7 Extension Cords . . . . . . . . . . . . . . .
Краткое содержание страницы № 4
iv | welcome Thank you for purchasing this Remington brand Electric Blower/Vac. We are proud to offer this quality product to assist you in keeping your property neat and well- groomed. This owner’s manual provides complete instructions for safely assembling, operating, and maintaining your Blower/Vac. Read and save these instructions. Refer to this manual each time before using your Blower/Vac. For easy reference, record the information from the carton and Remington brand nameplate labe
Краткое содержание страницы № 5
Remington elect Ric blowe R/a v c | 1 1 important safety information BEFORE OPERATING WHILE OPERATING SAFETY BLOWER/VAC BLOWER/VAC WARNINGS 1. Stay alert. Watch what you are doing. READ ALL INSTRUCTIONS BEFORE When using an electric appliance, basic Use common sense. OPERATING THIS BLOWER/VAC. precautions should always be followed, 2. Keep hair, loose clothing, fingers, and 1. Avoid Dangerous Environments including the following: all parts of body away from openings • This b
Краткое содержание страницы № 6
2 | chapter 1: i mportant Safety i nformation parts, mounting, and any other con- MAINTENANCE AND dition that may affect its operation. STORAGE OF BLOWER/VAC • A guard or other part that is dam- 1. Maintain blower/vac with care. aged should be properly repaired • Do not use with damaged cord or or replaced by a qualified service plug. center unless indicated elsewhere • If blower/vac is not working prop- in this manual. erly, has been dropped, damaged, 3. Store idle blower/vac indoors. W
Краткое содержание страницы № 7
Remington elect Ric blowe R/a v c | 3 2 product identification A. Blower/Vac Housing B. On/Off Switch C. Blower Tube L E D. Bottom Inlet Cover E. Vacuum Bag Adapter F. Vacuum Bag G. Vacuum Tube Adapter H. Upper Vacuum Tube F I. Lower Vacuum Tube J. Extension Cord Retainer K. Inlet Plug L. Draw Latch B G C H L I A K D J Figure 2-1: Remington brand electric blower/vac Specifications BV12200A BV12200AT Input 120V, 12A 120V, 12A Max. Blower Velocity 200 mph 200 mph 3 3 Max. Blower Air Ou
Краткое содержание страницы № 8
4 | 3 blower/vac assembly Assembling Blower 1 WARNING: To Reduce The Risk of Personal Injury or Electric Shock – Disconnect from power source before assembling or changing attachments. Follow the steps below to assemble the blower. IMPORTANT: The blower will not Figure 3-1: Sliding blower tube into place run unless the bottom inlet cover is locked into place. 4 1. Slide the blower tube onto outlet on front of blower/vac housing (see Fig- Figure 3-4: Pivoting bottom inlet cover to bl
Краткое содержание страницы № 9
Remington elect Ric blowe R/a v c | 5 Converting from Blower to Vacuum WARNING: To Reduce The Risk of Personal Injury or Electric Shock – Disconnect from power source before assembling or changing attachments. Follow the steps below to convert from Figure 3-6: Sliding vacuum tube adapter into place blower to vacuum. IMPORTANT: The 1 vacuum will not run unless the vacuum tube assembly is locked into place. 1. Press locking lever on bottom inlet cover and remove bottom inlet
Краткое содержание страницы № 10
6 | chapter 3: blower/v ac a ssembly Converting from Blower to Vacuum, continued 4. Connect the tubes to the vacuum tube adapter (see Figure 3-9). Align the tab on the top tube with the notch on the vacuum tube adapter. Press together until you hear a “snap”. 2 Notch 5. Position front of vacuum tube adapter 5 assembly over motor housing hook (see Figure 3-10). Figure 3-11: Pivoting vacuum tube adapter to Tab 6. Pivot vacuum tube adapter assembly blower/vac housing to bottom of blower/
Краткое содержание страницы № 11
Remington elect Ric blowe R/a v c | 7 4 blower/vac operation IMPORTANT: This blower/vac is for house- To reduce the risk of electric shock, this hold use only. blower/vac has a polarized plug (one blade is wider than the other) and will require the use of a polarized extension cord. The WARNING: Read and under- blower/vac’s plug will fit into a polarized stand this owner’s manual before extension cord only one way. If the plug operating blower/vac. Make cer- does not fit fully
Краткое содержание страницы № 12
8 | chapter 4: blower/v ac operation Operating the Blower/Vac The on/off toggle switch has three settings; off, low, and high. The middle switch po- sition, marked “O”, is off. The rear switch position, marked “I”, is low. The forward switch position, marked “II”, is high. See Figure 4-4. Blower Operation WARNING: The blower can throw debris, causing injury to those nearby. • Do not blow nails, bolts, rocks, Figure 4-4: On/Off switch positions or other hard objects. Figure 4-6: On/Of
Краткое содержание страницы № 13
Remington elect Ric blowe R/a v c | Vacuum Operation CAUTION: Normal vacuum usage causes the vacuum bag to WARNING: The vacuum can wear and deteriorate. A worn or throw debris, causing injury to deteriorated bag allows vacuum those nearby. to throw debris through the bag, possibly hitting and injuring the • Do not operate vacuum without operator. Check vacuum bag fre- the vacuum bag attached or quently. If it is worn, deteriorated, with the bag zipper opened. or damaged,
Краткое содержание страницы № 14
10 | chapter 4: blower/v ac operation Emptying the Vacuum Bag Removing Clogged Debris from the Impeller 1. Turn vacuum off and unplug power cord. 1. Turn vacuum off and unplug power cord. 2. Lift and release draw latch on vacuum bag adapter and remove from blower/ 2. Press locking lever on vacuum tube vac housing (see Figure 4-10). adapter and remove tube adapter as- sembly from blower/vac (see Figures 3. Unzip vacuum bag and shake out 4-12 and 4-13). contents (see Figure 4-11). 3. Chec
Краткое содержание страницы № 15
Remington elect Ric blowe R/a v c | 11 5 blower/vac maintenance Use a soft cloth dampened with a mild Cleaning and Servicing of soap and water mixture to wipe blower/vac Maintenance housing. Do not spray or pour water directly Double-Insulated onto blower/vac. Appliances WARNING: Disconnect blower/ When not in use, store the blower/vac and vac from power supply before A double-insulated appliance is marked extension cord indoors in a dry location. cleaning or servicing. Sever
Краткое содержание страницы № 16
12 | 6 troubleshooting WARNING: Unplug blower/vac from power source before servicing. Severe injury or death could occur from fire, electrical shock, or rotating impeller. Note: For additional help, visit our technical ser vice web site at www.desatech.com. OBSERVED FAULT POSSIBLE CAUSE REMEDY Motor does not run when you turn on/off 1. Bottom inlet cover or vacuum tube 1. Check inlet cover or vacuum tube switch low or high adapter not locked into place adapter for proper installation (
Краткое содержание страницы № 17
Remington elect Ric blowe R/a v c | 13 7 replacement parts Replacement Parts Use the part numbers below to order replacement parts for your blower/vac. Part Item Description Number 1 Blower Tube 120473-01 2 Bottom Inlet Cover 120474-01 3 Vacuum Bag with Adapter 120475-01 4 Upper Vacuum Tube with Adapter 120476-01 5 Lower Vacuum Tube 118069-01 1 3 2 4 5 120133
Краткое содержание страницы № 18
14 | 8 warranty information REMINGTON BRAND ELECTRIC BLOWER/VAC LIMITED WARRANTIES NEW PRODUCTS Standard Warranty DESA Power Tools warrants this new product and any parts thereof to be free from defects in material and workmanship for a period of two (2) years from the date of first purchase from an authorized dealer provided the product has been maintained and operated in accordance with DESA Power Tools’ warnings and instructions. FACTORY RECONDITIONED PRODUCTS Limited Warranty DESA Power
Краткое содержание страницы № 19
® SOPLADORA/ASPIRADORA ELÉCTRICA MANUAL DEL PROPIETARIO MODELOS: BV12200A, BV12200AT IMPORTANTE: Lea y entienda este manual antes de ensamblar u operar esta podadora. El uso incorrecto de esta podadora puede causar una lesión severa o la muerte. Guarde este manual como referencia para el futuro. Con doble aislamiento
Краткое содержание страницы № 20
120133