Краткое содержание страницы № 1
1
W415-0638 / 04.24.08
$10.00 W415-0638 / 04.24.08
Краткое содержание страницы № 2
2 TABLE of CONTENTS PG 2-4 INTRODUCTION 7 FINISHING Warranty Log Placement General Information 8 OPERATION 5 SPECIFICATIONS Operating Instructions Dimensions Maintenance Input 9 MAINTENANCE Gas Inlet Pressures High Elevation Installation Minimum Clearance to Combustibles 10-11 REPLACEMENTS 6-7 INSTALLATION Natural Gas Ordering Replacement Parts Propane Replacement Parts Enclosures for LP Gas Supply Systems Tank Retaining Br
Краткое содержание страницы № 3
3 NAPOLEON® gas appliances are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certifi cate. NAPOLEON® products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. Th e burner and valve assembly are leak and test-fi red at a quality test station. Once assembled the complete appliance is thoroughly inspected by a qualifi ed technician before packaging to ensure that you, the custo
Краткое содержание страницы № 4
4 GENERAL INFORMATION • Installation and repair should be done by a THIS GAS FIREPLACE SHOULD BE INSTALLED AND qualifi ed service person. The appliance should be SERVICED BY A QUALIFIED INSTALLER to conform inspected before use and at least annually by a with local codes. qualifi ed service person. More frequent cleaning Installation practices vary from region to region and it is may be required as necessary. It is imperative the important to know the specifi cs that apply to your area,
Краткое содержание страницы № 5
5 SPECIFICATIONS DIMENSIONS INPUT Model Fuel Max. Input Btu/Hr GPFN Natural Gas 60,000 GPFP Propane Gas 60,000 GAS INLET PRESSURES Natural LP (Propane) Minimum Inlet Pressure 4.5" w.c. 11.0" w.c. Maximum Inlet Pressure 14.0"w.c 14.0"w.c. MINIMUM CLEARANCE TO COMBUSTIBLES Inches mm Floor *0 *0 Side Walls 24 610 Top of unit to ceiling 72 1.830 * WHEN THE PATIO FLAME IS BEING USED WITH THE OP- TIONAL TRIPOD, IT MUST NOT BE SITUATED ON A COMBUS- TIBLE SURFACE. W415-0638 / 04.24.08
Краткое содержание страницы № 6
6 INSTALLATION The log set and the burner assembly are shipped together. ENCLOSURES FOR LP GAS SUPPLY Remove the gas log set and burner assembly and check for SYSTEMS damage. DO NOT install damaged components. The logs are If you build an enclosure for an LP gas cylinder, follow these fragile use care when handling. recommended specifi cations. You must also follow local Place the Patiofl ame on a level/secure surface in desired codes. location. This location must be adjacent to the gas supp
Краткое содержание страницы № 7
U R H 7 TANK RETAINING BRACKET #2 1. Fasten the bracket to the bottom of the propane bottle using bolt and nut supplied. (Fig. 1) 2. Tighten the lag screw into the mounting surface leaving 1 approximately / ” of thread above the surface. 4 3. Slide propane bottle into position so that the bracket slides under the head of the lag screw. (Fig. 2) 4. Tighten the lag screw onto the bracket. 5. For fastening to a concrete surface a concrete anchor will 3. Place pocket on log #2 onto the lo
Краткое содержание страницы № 8
8 OPERATION Upon completing the gas line connection, a small amount of Once the purging is complete, the burner will light and operate air will be in the lines. When fi rst lighting the burner, it will take as indicated in the instruction manual. Subsequent lighting a few seconds for the lines to purge themselves of this air. of the appliance will not require such purging unless the gas supply has been disconnected. WARNING: Read and follow the safety and lighting instructions page in this man
Краткое содержание страницы № 9
9 MAINTENANCE 1. The appliance should be inspected before initial use and During the winter months in cold weather climates, it is inspected and cleaned at least annually by a qualifi ed fi eld recommended to disconnect the Patiofl ame and store it in a service person. cool dry place. Do not store the propane tank inside. For the 2. Tampering is DANGEROUS and voids all warranties. Any remainder of the year, protect and cover your Patiofl ame from component that is found to be faulty, must be r
Краткое содержание страницы № 10
10 1. REPLACEMENTS Contact your Napoleon® dealer or the factory for questions MODEL & SERIAL NUMBER OF APPLIANCE concerning prices and policies on replacement parts. Normally 2. INSTALLATION DATE OF APPLIANCE all parts can be ordered through your Napoleon® dealer or ART NUMBER 3. P distributor. 4. DESCRIPTION OF PART When ordering replacement parts always give the following 5. FINISH information: * IDENTIFIES ITEMS WHICH ARE NOT ILLUSTRATED. FOR FOR WARRANTY REPLACEMENT PARTS, A PH
Краткое содержание страницы № 11
11 W415-0638 / 04.24.08
Краткое содержание страницы № 12
12 W415-0638 / 04.24.08 Wolf Steel Appliance Service History This appliance must be serviced annually depending on usage. Service Technician Date Dealer Name Service Performed Special Concerns Name