Краткое содержание страницы № 1
WS-9014U
Wireless 433 MHz
Temperature Station
Instruction Manual
1
Краткое содержание страницы № 2
TABLE OF CONTENTS Topic Page Inventory of Contents 3 Quick Setup 4-8 Detailed Setup Guide Battery Installation 9-10 Setting the Time 11-12 Selecting Units of 12-13 Measurement Features Minimum and Maximum 13 Temperatures Resetting Minimum and 14 Maximum Temperatures Additional remote 14-17 temperature sensors (optional) Mounting 17-18 Troubleshooting 19-21 Maintenance and Care 21 Specifications 22-23 Warranty Information 24-27 2
Краткое содержание страницы № 3
INVENTORY OF CONTENTS 1. The indoor temperature station (Figure 1) 2. The remote temperature sensor (TX6U) and mounting bracket. (Figure 2) 3. 3 each, 1/2” Philips screws. 4. One strip of double sided adhesive tape. 5. Instruction Manual and Warranty Card. Figure 1 Figure 2 ADDITIONAL EQUIPMENT (not included) 1. 1 Philips screwdriver. 2. 2 Fresh AA 1.5V batteries. 3. 2 Fresh AA 1.5V batteries. 3
Краткое содержание страницы № 4
QUICK SETUP Hint: Use good quality Alkaline Batteries and avoid rechargeable batteries. 1. Have the indoor temperature station and remote temperature sensor 3 to 5 feet apart. 2. Batteries should be out of both units for 10 minutes. 3. Place the batteries into the remote temperature sensor first then into the indoor temperature station. (All remote temperature sensors must be started before the indoor temperature station) 4. DO NOT PRESS ANY BUTTONS FOR 10 MINUTES. 4
Краткое содержание страницы № 5
In this time the indoor temperature station and remote temperature sensor will start to talk to each other and the display will show both the indoor temperature and an outdoor temperature. If the indoor temperature station does not display both temperatures after the 10 minutes please retry the set up as stated above. After both indoor and outdoor temperatures are displayed for 10 minutes you can place your remote temperature sensor outdoors and set your time. The remote tempera
Краткое содержание страницы № 6
of resistance. Your distance plus resistance should not exceed 80 ft. in a straight line. NOTE: Fog and mist will not harm your remote temperature sensor but direct rain must be avoided. To complete the set up of your indoor temperature station after the 10 minutes have passed please follow the steps below. 1. Press and hold the “SET” button for 5 seconds. Note: A “12h” or “24h” will appear on the top line. (“12h” for AM/PM, “24h” for military time) a. To change between “12h
Краткое содержание страницы № 7
b. When you have your choice shown on the display press and release the “SET” button once. 2. Degree Fahrenheit will now show. a. To change between Fahrenheit and Celsius, press and release the “MIN/MAX” button. b. When you have your choice shown on the display press and release the “SET” button once. 3. An hour will now be flashing. a. Press and release the “MIN/MAX” button until the correct hour is shown. Note: When in the 12h mode there is “PM” displayed under the word T
Краткое содержание страницы № 8
PM hours. During the AM hours this area will be blank. b. When the correct hour is shown, press and release the “SET” button once. 4. A minute will now be flashing. a. Press and release the “MIN/MAX” button until the correct minutes are displayed. Press and release the SET button once more and you are done. DETAILED SETUP GUIDE I. BATTERY INSTALLATION A. REMOTE TEMPERATURE SENSOR 8
Краткое содержание страницы № 9
1. Remove the mounting bracket. 2. Remove battery cover 3. Observing the correct polarity, install 2 AA batteries—make sure they do not spring free, or start-up problems may occur. Replace cover. B. INDOOR TEMPERATURE STATION Note: After the batteries are installed, DO NOT press any buttons. This may interfere with the signals, causing temperatures to register incorrectly. 9
Краткое содержание страницы № 10
1. Remove the battery cover on the backside. To do this, push up and pull out. 2. Observing the correct polarity, install 2 AA batteries. 3. Replace battery cover. 4. Wait 10 minutes or until both the indoor and outdoor temperatures are shown on the indoor temperature station. 5. The indoor temperature station should now show: “-:- - ” in the TIME LCD, and temperatures in the INDOOR and OUTDOOR LCD’s. 10
Краткое содержание страницы № 11
II. TIME A. SETTING THE TIME 1. Press and hold the “SET” button for 5 second, “12h” will appear in the TIME LCD. 2. Press and release the “MIN/MAX” button to select either 12h time (am/pm) or 24h time 3. Press and release the “SET” button 2 times, the hour will flash in the upper left corner. 4. Press and release the “MIN/MAX” button to set the hours 5. Press and release the “SET” button to move to the minute setting 6. Press and release the “MIN/MAX” button to set the mi
Краткое содержание страницы № 12
Note: When in 12h mode, there is only a “PM” display, which appears under “TIME.” If there is no display here it is AM. Make sure you set the time accordingly. III. UNITS OF TEMPERATURE MEASURE A. SELECTING UNITS OF MEASUREMENT 1. Press and hold the “SET” button for 5 second until “12h” or “24h” appears in the TIME LCD. 2. Press and release the “SET” button again, “ °F” will appear in the TIME LCD. 3. Press and release the “MIN/MAX” button to shift between °F and °C. 4.
Краткое содержание страницы № 13
IV. FEATURES A. MINIMUM AND MAXIMUM TEMPERATURES 1. Press and release the “MIN/MAX” button, “MIN” appears in the temperature LCD’s and the recorded minimum temperatures are displayed. 2. Press and release the “MIN/MAX” button to toggle to the maximum temperatures. The time of occurrence of the value for outdoor temperature will also flash. B. RESETTING THE MINIMUM AND MAXIMUM TEMPERATURES 1. To reset both the minimum and maximum temperatures—press and hold the “RESET/+” butt
Краткое содержание страницы № 14
1. The WS-9014U is able to receive signals from 3 different remote temperature sensors. Following are some brief instructions for the basic set-up of remote temperature sensor units with the WS-9014U. These extra sensors can be purchased through the same dealer as this unit, or by contacting La Crosse Technology directly. A TX6 will monitor temperature only, a TX3U will monitor temperature and display the temperature on its LCD, and the TX3UP will monitor the temperature via a pro
Краткое содержание страницы № 15
the total time for set-up exceeds 6 minutes. 2. It is necessary to remove the batteries from all units currently in operation. 3. Remove the battery covers to all remote temperature sensor units. 4. Place all remote temperature sensor units in a numeric sequential order. 5. In sequential order, install batteries (follow the same battery installation procedures seen in section “I” of the Detailed Set-Up Guide). 6. Install batteries into the indoor temperature station. 7. Follow the
Краткое содержание страницы № 16
from one “boxed” number to the next should be observed in the OUTDOOR LCD. 2. To view the Minimum/Maximum temperature: first select from which remote temperature sensor to read data (indicated by the “boxed” number). Pressing and releasing the “MIN/MAX” button will toggle through the minimum and maximum indoor temperature, and the minimum and maximum outdoor temperature. 3. To reset the Minimum/Maximum readings, press and hold the “MIN/MAX” button for four seconds. V. MOUNTING
Краткое содержание страницы № 17
both units in their desired location before permanently mounting. A. REMOTE TEMPERATURE SENSOR 1. Remove the mounting bracket from the remote temperature sensor 2. Mount using either screws or adhesive tape. 3. Reattach the remote temperature sensor to the mounting bracket. B. THE TEMPERATURE STATION 1. The indoor temperature station comes with the table stand already mounted. If you wish to use the table-stand, all that is required is to place the indoor temperature station
Краткое содержание страницы № 18
temperature station onto the screw using the hanging hole on the backside. Gently pull the indoor temperature station down to lock the screw into place. TROUBLESHOOTING NOTE: For problems not solved, please contact La Crosse Technology via e-mail or phone, or visit our website, www.lacrossetechnology.com Problem: The LCD is faint Solution: Replace batteries Problem: No outdoor temperature is displayed. Solution: 1) Remove all batteries, reinsert into remote temperature s
Краткое содержание страницы № 19
4) Place remote temperature sensor and indoor temperature station in position so the straight-line signal is not passing through more than two or three walls. Problem: Temperatures do not match if units are placed next to each other. Solution: Each temperature sensor is manufactured to be accurate to within 1 degree plus or minus and under normal conditions; so two temperature sensors could be as much as 2 degrees different. However, the difference can be exaggerated further becaus
Краткое содержание страницы № 20
ends of a range, making it harder to compare different ranges with different curves. Under non-laboratory conditions, it is difficult to compensate for the above factors and obtain an accurate comparison. MAINTENANCE AND CARE INSTRUCTIONS • Extreme temperatures, vibration, and shock should be avoided to prevent damage to the units. • Clean displays and units with a soft, damp cloth. Do not use solvents or scouring agents; they may mark the displays and casings. • Do not submer