The.Danger.signal.indicates.an.immediately.hazardous.situation.which,.
if.not.avoided,.will result.in.death.or.serious.injury.
The.Warning.signal.alerts.you.to.potential.hazards.or.unsafe.practices.which,.
if.not.avoided,.could result.in.severe.personal.injury.or.death.
The.Caution.signal.alerts.you.to.hazards.of.unsafe.practices.which,.if.not.avoided,.
may.result.in.minor.personal.injury.or.property.damage.
Please.be.certain.that.the.person.who.installs.or.uses.this.appliance.carefully.
reads.a
Краткое содержание страницы № 2
Table of Contents Warranty...........................................................................................................4 Introduction/Typical Installation . Introduction.......................................................................................4 . Typical.Installation.............................................................................4 Waste Xpress Features...................................................................................5 WX-101A Control Featu
Краткое содержание страницы № 3
Warranty WASTE XPRESS SYSTEM LIMITED WARRANTY ® ® The.InSinkErator .Waste.Xpress,.disposer.and.control.centers.are.warranted.against.defects.in.material.and. workmanship.for.one.year.from.the.date.of.installation..The.warranty.includes.parts.and.labor,.provided.an.. InSinkErator.Factory.Authorized.Service.Center.performs.the.service..This.warranty.does.not.apply.if.the.failure.. is.due.to:.faulty.or.improper.electrical.installation,.faulty.or.improper.plumbing.installation,.product.abuse.or.. mi
Краткое содержание страницы № 4
Waste Xpress Features CONSTRUCTION FEATURES Stainless.steel.construction.(for.physical.size.see.. COMPACT.SIZE ® Figure.3). The.Waste.Xpress .is.designed.to.fit.under.a.34".high commercial.kitchen.table. WASTE.MIX The.Waste.Xpress.can.process.non-food.waste.such WASTE.REDUCTION as.paper,.light.and.rigid.plastic.or.food.wrappings.when Reduces.volume.by.85%. mixed.with.a.minimum.of.50%.food.waste. SAFETY.INTERLOCK The.Waste.Xpress.is.equipped.with.safety.interlock.. on.the.discharge.chute.(see.Fig
Краткое содержание страницы № 5
WX-101A Control Features/Mounting Control Center ® The.WX-101A.Control.Center.is.UL .approved.for.use. with.InSinkErator.Waste.Xpress.food.waste.reduction. systems..The.control.center.operates.the.disposer.and. ELECTRICAL SHOCK Waste.Xpress..Its.main.functions.are: .•.Ensure.that.Waste.Xpress.voltage.and.phase. match.that.of.the.electrical.supply,.control.center.. •.To.start.and.stop.the.disposer/Waste.Xpress.system. &.disposer..Check.nameplate.for.specification. •.To.reverse.the.direction.of.th
Краткое содержание страницы № 6
Installing Disposer CLEAN.THE.DRAIN.LINE With.a.drain.line.auger,.clear.away.all.hardened.waste material.in.the.horizontal.drainpipe.running.from.the PERSONAL INJURY drain.trap.to.the.main.waste.line. .•.For.safe.operation,.The.minimum.required.distance . from.the.table.top.or.trough.to.the.mounting.flange. is.6.inches.for.standard.body.disposers.. (as.specified.by.UL)..See.Figure.5. 6" min. (152.4 mm min.) .•.Moving.shredder.parts.may.cause.serious.injury.if. a.hopper.or.cone.is.not.properly.in
Краткое содержание страницы № 7
InSinkErator Mounting Assemblies 4..From.the.bottom,.insert.two.screws.through.opposite STANDARD MOUNTING ASSEMBLY . sides.of.the.flat.gasket.(3).and.mounting.flange,.into 1..Place.mounting.flange.(1).over.the.existing.collar . the.threaded.fasteners.in.the.existing.flange..The . adaptor.connection.lip.or.sink.bowl.flange.(this.may . flat.gasket.is.used.only.in.the.#6.mounting.assembly. . require.some.force). . The.screws.should.protrude.about.1/4".below.the 2..Push.the.mounting.flange.up.out.of
Краткое содержание страницы № 8
Installing the Waste Xpress 45˚ bend shown (max of 4 can be used) 1-1/2" 3" (38.1 mm) (76.2 mm) Figure 11. Top View Syphon Breaker Sink Bowl Cold Water Solenoid Hot Water Solenoid Waste Xpress 1-1/2" min 1" min (38.1 mm (25.4 mm min) min) Disposer Flow Control Valve Shut Off Valve (supplied by others) WX-101A Controller 10 max (3.1 m max) Figure 12. Typical Installation Diagram 9
Краткое содержание страницы № 9
Installing the Waste Xpress 7....Connect.wire.bundle.between.WX-101A.and.. WASTE XPRESS LOCATION Waste.Xpress.unit.as.detailed.in.wiring.diagram.. NOTE: Prior to installing the Waste Xpress the Door.interlock.connections.are.#3.and.#95..Replace. disposer and control center should be installed as terminal.cover. specified within this manual. 8....Wire.per.local.electrical.codes.and.install.. •.Position.Waste.Xpress.within.10.feet.of.the.disposer using.NEMA.4.watertight.electrical.connectors.. out
Краткое содержание страницы № 10
Plumbing Connections PROPERTY DAMAGE Water.connections.must.comply.with.all.local. plumbing.codes. WASTE INLET LINE Connect.the.disposer.outlet.flange.as.close.as.. possible.and.with.as.few.as.possible.90°.elbows.to.. the.Waste.Xpress.inlet. NOTE: The maximum allowable distance between the Figure 15. disposer outlet flange and the Waste Xpress inlet is 10 feet with a maximum of four (4) 90° elbows. 1..Connect.the.disposer.outlet.to.the.Waste.Xpress.. . inlet.using.2".NPT.plumbing..3.HP.will.re
Краткое содержание страницы № 11
Plumbing Connections WASTE OUTLET LINE WATER SUPPLY CONNECTIONS Connect.a.2".drain.line.to.the.Waste.Xpress.waste.. When.connecting.the.incoming.water.supply.to.the outlet.as.specified.per.local.codes.(see.Figure.18.. disposer,.sink.bowl.and.Waste.Xpress,.use.as.few for.water.outlet.location). elbows.and.tees.as.possible. InSinkErator.recommends.that.the.water.outlet.. All.cold.water.line.fittings.are.1/2".NPT.except.the empties.into.a.floor.drain. sink.bowl.nozzles.which.are.1/2".compression...
Краткое содержание страницы № 12
Electrical Connections ELECTRICAL SHOCK PROPERTY DAMAGE .•.Turn.off.all.electrical.supply.to.the.disposer.before. .•.Ensure.that.control.center.voltage.and.phase attempting.any.work.on.it..Use.a.voltmeter.or.. . match.the.disposer.motor.and.electrical.supply... circuit.tester.to.ensure.that.power.is.off. . Check.nameplates.on.disposer.and.control.. . center.for.voltage.and.phase.specifications. .•.All.Installation.work.must.conform.to.local.. plumbing.and.electrical.codes. .•.Refer.to.the.contro
Краткое содержание страницы № 13
Operating Instructions PRE-OPERATION TEST Before.operating.the.Waste.Xpress.complete.. the.following.steps.to.ensure.the.unit.has.been.. PERSONAL INJURY properly.installed. If.system.does.not.shut.down.when.front.. cover/discharge.chute.is.removed,.interlock.may. 1....Ensure.plumbing.and.electrical.connections.. not.be.wired.correctly..See.Troubleshooting.section. are.secure. for.corrective.action. 2....Turn.on.incoming.cold.water.supply.to.disposer.. and.hot.water.supply.to.the.Waste.Xpress. 3.
Краткое содержание страницы № 14
Operating Instructions TO.START 1..Check.to.ensure.disposer.is.free.of.foreign.objects. 2..Ensure.power.is.on. 3..Push.start.button..Disposer.and.Waste.Xpress.will. run.and.water.will.flow.into.disposer TO.STOP 1..Push.stop.button..System.will.stop. 2..Water.may.continue.to.flow.into.disposer.for.up.to.. 10.minutes,.per.the.time.set.on.the.water.shutoff. delay.timer..This.post-flush.clears.the.drain.lines.. of.food.waste. WATER.SHUTOFF.DELAY.ADJUSTMENT This.water.shutoff.delay.is.adjustable.from
Краткое содержание страницы № 15
Operating Instructions OPERATING WASTE XPRESS SYSTEM 1..Make.sure.there.are.no.foreign.objects.in.disposer. grind.chamber..Do.not.pre-load.disposer.with.food. waste.prior.to.starting. 2..Place.10.gallon.waste.bin.under.discharge.chute. 3..Push.start.button.on.control.center..Waste.Xpress. and.disposer.will.run.and.water.will.flow.into.disposer. 4..Feed.food.waste.into.disposer.in.a.steady,.. continuous.flow..Waste.will.exit.discharge.chute.. and.drop.into.waste.bin. NOTE: Once all waste has been
Краткое содержание страницы № 16
Cleaning Instructions PERSONAL INJURY Discharge Chute Wait.until.auger.paddles.stop.before.cleaning. Waste.Xpress. 1....Press.stop.button.on.control.center.to.stop.system. (disposer.&.Waste.Xpress). 2....Holding.both.handles.remove.discharge.chute.by.. tilting.it.upward.(see.Figure.25). 3....Remove.auger-bearing.bracket.by.sliding.the.two. captive.fasteners.inward.and.then.pull.bracket.. Figure 25. upward.(see.Figure.26.and.27). 4....Lift.auger.and.screen.up.and.then.out.. (see.Figure.26). 5....
Краткое содержание страницы № 17
Troubleshooting ELECTRICAL SHOCK PERSONAL INJURY •.Disconnect.power.before.servicing. Wait.until.auger.paddles.stop.before.servicing. Waste.Xpress. •.Do.not.bypass.interlock.switch. Troubleshooting.for.problems.other.than.what.is.listed.below.should.be.performed.by.a.qualified.service.person.. Troubleshooting.performed.by.untrained.personnel.could.result.in.electrical.shock.or.damage.to.the.Waste.Xpress,. disposer.and/or.Control.Center. SYSTEM TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION The.
Краткое содержание страницы № 18
Troubleshooting SYSTEM TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION Water.backs.up.into.disposer.. •. The.auger.and.screen.plugged. •. Remove.plug. (does.not.drain). •. Auger.not.turning.. •. Ensure.that.auger.is.seated.properly.and.. . that.auger.belt.in.place..Check.motor. •. Plumbing.line.between.disposer.and.. •. Remove.clog. . Waste.Xpress.clogged. Waste.Xpress,.disposer.and.water. •. Insufficient.time.allowed.after.Line.. •. Allow.15-20.seconds.prior.to.attempting.. will.start.when."sta
Краткое содержание страницы № 19
Troubleshooting SYSTEM TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION No.water.spraying.onto.. •. Solenoid.valve.clogged. •. Remove.clog. auger.screen. •. Water.turned.off. •. Turn.on.water. •. Solenoid.valve.defective. •. Call.for.service. •. Spray.nozzles.clogged. •. Replace.nozzles. •. Timer.defective. •. Call.for.service. •. Timer.not.set.properly. •. Call.for.service. •. Solenoid.valve.installed.incorrectly. •. Reinstall.solenoid.valve.so.arrow.is.pointing. . in.correct.direction. Water.fl
Краткое содержание страницы № 20
Troubleshooting DISPOSER TROUBLESHOOTING PROBLEM CAUSE SOLUTION Disposer.motor.will.not.start.and. •. No.incoming.line.power. •. Turn.line.power.on. water.does.not.flow. •. Line.disconnect.switch.is.not.on.. •. Turn.line.disconnect.to."on".position..Wait.. . . 15-20.seconds.before.attempting.to.start.. . system.to.allow.control.to.perform."self.test." •. Line.disconnect.switch.has.been.. •. Wait.30.seconds.and.try.starting.again.. . reactivated.and.30-second.delay.. . . has.not.yet.expired. •. L