Краткое содержание страницы № 1
DISPOSER CONTROL CENTER
Installation Manual
Model MS
The Danger signal indicates an immediately hazardous situation which, if not
avoided, will result in death or serious injury.
The Warning signal alerts you to potential hazards or unsafe practices which,
if not avoided, could result in severe personal injury or death.
The Caution signal alerts you to hazards of unsafe practices which, if not avoided,
may result in minor personal injury or property damage.
Please be certain that the person
Краткое содержание страницы № 2
Table of Contents Introduction/Features Introduction ......................................................................................3 Features .......................................................................................... 3 Mounting the Control Center .......................................................... 3 Plumbing Connections ................................................................................. 4 Electrical Connections Electrical Connections ............
Краткое содержание страницы № 3
Features/Mounting the Control Center INTRODUCTION MOUNTING THE CONTROL CENTER ® ® The MS Control Center is UL and CUL approved for Use the flanges at the back of the control center use with InSinkErator Foodservice Disposers. See enclosure and only mount panel in the upright vertical Table 1 for approved disposer and control center position. See Figure 1. combinations. The control center operates the disposer. Its main functions are: Locate control center within sight of disposer per local
Краткое содержание страницы № 4
Plumbing Connections Figure 2. Typical Installation Diagram PLUMBING CONNECTIONS The flow control valve, syphon breaker and solenoid valve are supplied with all complete disposer packages (packed separately). Make certain that the solenoid valve supplied is the proper voltage. Make certain that the valves are plumbed according to water flow direction arrows marked on valves or the valves will not function properly. The flow control valve regulates all water flowing into the disposer.
Краткое содержание страницы № 5
Electrical Connections ELECTRIC SHOCK PROPERTY DAMAGE • Ensure that control center voltage and phase • Turn off the electrical supply to the disposer before match the disposer motor and electrical supply. attempting any work on it. Use a voltmeter or Check name plates on disposer and control circuit tester to ensure that power is off. centers for voltage and phase specifications. • All installation work must conform to local • Refer to the control center wiring diagrams in this
Краткое содержание страницы № 6
Operating Instructions/Troubleshooting PERSONAL INJURY ELECTRICAL SHOCK/PROPERTY DAMAGE • Allow only trained personnel to operate disposer. • Troubleshooting other than what is recommended in this section should only be performed by • Use baffles and guarding to avoid splashing and qualified service personnel. ejection of materials. • Further troubleshooting performed by untrained • Do not put fingers or hands into the disposer. personnel could result in electric shock or damage • Whe
Краткое содержание страницы № 7
1 2 4 3 5 7 6 MS-4 Wiring Diagram P/N 14356 ELECTRICAL SHOCK PROPERTY DAMAGE • Turn off the electrical supply to the disposer before • Ensure that the control center voltage and phase attempting any work on it. Use a voltmeter or match the disposer motor and electrical supply. circuit tester to ensure that power is off. Check nameplates on disposers and control centers for voltage and phase specification. • Installation must conform to local electrical codes. • The disposer motor wiring
Краткое содержание страницы № 8
2 3 1 4 5 7 6 MS-5 Wiring Diagram P/N 14356A ELECTRICAL SHOCK PROPERTY DAMAGE • Turn off the electrical supply to the disposer before • Ensure that the control center voltage and phase attempting any work on it. Use a voltmeter or match the disposer motor and electrical supply. circuit tester to ensure that power is off. Check nameplates on disposers and control centers for voltage and phase specification. • Installation must conform to local electrical codes. • The disposer motor wirin
Краткое содержание страницы № 9
3 6 9 12 2 5 8 11 1 4 7 10 MS-5 Wiring Diagram P/N 14356A ELECTRICAL SHOCK PROPERTY DAMAGE • Turn off the electrical supply to the disposer before • Ensure that the control center voltage and phase attempting any work on it. Use a voltmeter or match the disposer motor and electrical supply. circuit tester to ensure that power is off. Check nameplates on disposers and control centers for voltage and phase specification. • Installation must conform to local electrical codes. • The dispose
Краткое содержание страницы № 10
12 11 10 6 3 9 5 2 8 4 1 7 MS-6 Wiring Diagram P/N 14356B ELECTRICAL SHOCK PROPERTY DAMAGE • Turn off the electrical supply to the disposer before • Ensure that the control center voltage and phase attempting any work on it. Use a voltmeter or match the disposer motor and electrical supply. circuit tester to ensure that power is off. Check nameplates on disposers and control centers for voltage and phase specification. • Installation must conform to local electrical codes. • The dispose