Краткое содержание страницы № 1
Freestanding range
Installation instructions
OR24SDMBGX model
Cuiseur indépendant
Instructions d'installation
OR24SDMBGX model
1
US CA
Краткое содержание страницы № 2
WARNING • ALL RANGES CAN TIP • INJURY TO PERSON COULD RESULT • INSTALL ANTI-TIP DEVICE PACKED WITH RANGE • SEE INSTALLATION INSTRUCTIONS WARNING: IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH. ✓ Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. ✓ WHAT TO DO IF YOU SMELL GAS: • Do not try to light any appliance. • Do not touch any
Краткое содержание страницы № 3
DATA PLATE CONVERSION LABEL IMPORTANT - PLEASE READ AND FOLLOW ✓ Before beginning, please read these instructions completely and carefully. ✓ Do not remove permanently affixed labels, warnings, or plates from the product. This may void the warranty. ✓ Please observe all local and national codes and ordinances. ✓ Please ensure that this product is properly grounded. ✓ The electrical plug should always be accessible. ✓ The installer should leave these instructions with the consumer who should
Краткое содержание страницы № 4
INSTALLATION INSTRUCTIONS WARNING! THIS APPLIANCE HAS TO BE INSTALLED BY A QUALIFIED INSTALLER. Improper installation, adjustment, alteration, services, or maintenance can cause injury or property damage. Consult a qualified installer, service agent, or the gas supplier. IMPORTANT: The use of suitable protective clothing/gloves is recommended when handling, installing of this appliance. TOOLS NEEDED FOR INSTALLATION (NOT SUPPLIED WITH THE APPLIANCE) T-handle Tape Screwdriver 2 - Wrench wrench P
Краткое содержание страницы № 5
GENERAL INFORMATION 1. Installation must conform with local codes or, in the WARNING!! absence of local codes, with the National Fuel Gas Code, ANSI Z223.1-Latest Edition. ELECTRICAL GROUNDING INSTRUCTIONS The range must be electrically grounded in accordance 2. Installation in manufactured (mobile) home: installation with local codes or, in the absence of local codes, with the must conform with the Manufactured Home Construction National Electrical Code, ANSI/NFPA No. 70-latest editio
Краткое содержание страницы № 6
24" 5/64 (611.6 mm) 11" 15/16 11" 15/16 (303 mm) (303 mm) 1 A installation PROXIMITY TO SIDE CABINETS 1. This range may be installed directly adjacent to existing 36" (914 mm) high base cabinets. Range dimensions: • width: 23” 7/8 (606.5 mm) • depth: 24” 5/64 (611.6 mm) • height (without backguard): MIN 35” 7/16 (900 mm) - MAX 36” 7/32 (920 mm) • backguard (height): 4” 7/16 (113 mm) Gas line opening: Wall - 5” 57/64 (150 mm) from the floor; 11” 15/16 (303 mm) from the rear left side
Краткое содержание страницы № 7
0" 0" (0 mm) (0 mm) 20" min. (500 mm) 3" min. (76 mm) 13" max. (330 mm) 1 a PROXIMITY TO SIDE CABINETS Fig. 1.3a Fig. 1.3b A A B Fig. 1.4 ASSEMBLING THE BACKGUARD It is mandatory to install the backguard Assemble the backguard as shown in figure 1.5: • Screw the 2 screws “A” interposing the spacers. • Screw the central screw “B”. Fig. 1.5 7 13" max. (330 mm) 11" 13/16 min. (300 mm) 20" min. (500 mm) OVEN VENT 0" (0 mm) 0" (0 mm) 36" 30" min. (914 mm) (762 mm) 18" min. (457 mm) 18" min. (457 mm)
Краткое содержание страницы № 8
10" 15/64 (260 mm) = = 1 a LEVELLING THE RANGE The range is equipped with 4 LEVELLING FEET (SUPPLIED IN A SEPARATE KIT) and may be levelled by screwing or unscrewing the feet with a spanner (fig. 1.8). It is important to observe the directions of figures 1.6, 1.7a, 1.7b. Fig. 1.6 Supplied with the range Supplied with the range in a separate kit in a separate kit 0 mm + 8 mm 0" + 5/16" + 8 mm + 20 mm + 5/16" Fig. 1.7a + 25/32" Fig. 1.7b Fig. 1.8 ANTI-TIP STABILITY DEVICE INSTALLATION INSTR
Краткое содержание страницы № 9
gas connection 2 B All gas connections must be made according to national and local codes. This gas supply (service) line must be the same size or greater than the inlet line of the appliance. Sealant on all pipe joints must be resistant to te action of LP/Propane gas. The range is equipped for the use with NATURAL gas. It is design-certified by CSA International for NATURAL and L.P. gases with appropriate conversion. The model/serial rating plate, located inside the drawer, has information
Краткое содержание страницы № 10
2 b PRESSURE REGULATOR INSTALLATION STEP 1 Mount the 1/2” NPT (conical) male connector to the pressure regulator and tighten by using a wrench. LOCK Do not over tighten the connector. Over tightening may crack regulator. Arrow Fig. 2.2 STEP 2 Assemble the 1/2” NPT connector + pressure regulator group to the extension pipe interposing the gasket supplied. The regulator cover must be oriented toward the front side of the range. IMPORTANT: use two spanners to tighten the connection. Regul
Краткое содержание страницы № 11
2 b GAS CONNECTION SPECIFICATION Range manifold Manifold male pipe fitting 1/2” G cylindrical (ISO 228-1) male Gasket 1/2” G cylindrical (ISO 228-1) female To range Extension Extension pipe female pipe female pipe fitting pipe fitting Extension pipe Extension 1/2” G cylindrical pipe male (ISO 228-1) male pipe fitting Gasket 1/2” G cylindrical (ISO 228-1) female 1/2” NPT (conical) Connector male To main 1/2” NPT female connection Pressure regulator 1/2” NPT female Arrow WARNING: check the right
Краткое содержание страницы № 12
2 b b) Any conversion required must be performed by your dealer or a qualified licensed To range plumber or gas service company. Please provide the service person with this manual before work is started on the range. (Gas conversions are the responsibility of the dealer or end user.) c) This range can be used with NATURAL or LP/PROPANE gas. It is shipped from the factory adjusted for use with NATURAL gas. Manifold d) Manifold pressure should be checked with a manometer; NATURAL gas requires
Краткое содержание страницы № 13
3 2 b CONVERSION TO LP/PROPANE GAS Every range is provided with a set of injectors for the various types of gas. Select the injectors to be replaced according to the “INJECTORS TABLE”. The nozzle diameters, expressed in hundredths of a millimetre, are marked on the body of each injector. SETTING THE PRESSURE REGULATOR (fig. 2.6b) The pressure regulator is accessible by removing the bottom drawer; the pressure regulator is positioned on the rear left side of the range. To remove the drawer pro
Краткое содержание страницы № 14
2 b INJECTORS TABLE NOMINAL REDUCED LP/PROPANE NATURAL GAS POWER POWER 11” W.C.P. 4” W.C.P. Ø injector Ø injector J BTU/hr BTU/hr BURNERS [1/100 mm] [1/100 mm] Auxiliary (AUX) 3500 1000 55 90 Semirapid (SR) 6000 1500 72 118 Triple ring (TC) 12000 5000 102 170 Oven burner 13000 1500 109 180 Broil burner 8500 - 88 146 Fig. 2.7 OPERATIONS TO BE PERFORMED WHEN SUBSTITUTING THE INJECTORS ✓ Remove the gratings, the burner covers and the knobs; J ✓ Using a wrench substitute the nozzle injectors “J” (f
Краткое содержание страницы № 15
2 b OPERATIONS TO BE EXECUTED FOR THE REPLACEMENT OF THE INJECTORS OF THE OVEN AND BROIL BURNERS a) Oven Burner – Lift and remove the lower panel inside the oven. – Remove the burner securing screw (fig. 2.10). – Withdraw the burner as shown in figure 2.11 and rest it inside the oven. Take care not to damage the wire to the ignition electrode and the safety valve probe. Fig. 2.10 – Using a 7 mm box spanner, unscrew the injector (indicated by the arrow in fig. 2.11) and replace it by the prop
Краткое содержание страницы № 16
2 b ADJUSTMENT OF THE OVEN BURNER MINIMUM G This needs to be done only for the oven burner (the broil is a fixed capacity) by acting on the thermostat in the following way: – Turn on the burner by setting the thermostat knob on position 8. – Remove the knob and unscrew the by-pass screw "G" (fig. 2.14) about three times by passing a small flat screwdriver (Ø 3 mm blade, 100 mm length) through the panel opening. – Re-mount the knob and let the oven heat up for about 10 minutes, then bring the
Краткое содержание страницы № 17
3 electrical connection 3 If codes permit and a separate ground wire is used, it is recommended that a WARNING qualified electrician determine that the ground path is adequate. Check with a qualified electrician if you are not sure whether the range is properly grounded. Do Not ground to a gas pipe. A 120-volt, 60-Hz, AC-only, 15-ampere, fused electrical supply is required. A time-delay fuse or circuit breaker is recommended. It is recommended that a separate circuit serv- ing only this appli
Краткое содержание страницы № 18
c 3 WIRING DIAGRAM 18
Краткое содержание страницы № 19
19
Краткое содержание страницы № 20
AVERTISSEMENT • TOUS LES TYPES DE CUISINIÈRE PEUVENT BASCULER • CELA PEUT PROVOQUER DES BLESSURES • INSTALLEZ LE DISPOSITIF ANTIBASCULEMENT FOURNI AVEC LA CUISINIÈRE • CONSULTEZ LES INSTRUCTIONS D’INSTALLATION AVERTISSEMENT : SI L’INFORMATION CONTENUE DANS CE MANUEL N’EST PAS SUIVIE À LA LETTRE, UN INCENDIE OU UNE EXPLOSION PEUVENT SE PRODUIRE ET ENTRAÎNER DES DOMMAGES MATÉRIELS, DES BLESSURES OU MÊME LA MORT. ✓ Ne rangez pas et n’utilisez pas d’essence ou d’autres vapeurs et