Краткое содержание страницы № 1
INSTRUCTION MANUAL
Brad Nailer/Stapler
(Models DBN125,
DBS125, DNS100)
Model DBN125 Shown
PART NO. A04051 - 04-16-04
Copyright © 2004 Delta Machinery
ESPAÑOL: PÁGINA 15
To learn more about DELTA MACHINERY
FRANÇAISE : PAGE 27
visit our website at: www.deltamachinery.com.
For Parts, Service, Warranty or other Assistance,
please call 1-800-223-7278 (In Canada call 1-800-463-3582).
Краткое содержание страницы № 2
Date of Manufacture:___________________________ Fecha de fabricación:, Date de fabrication: Serial No:______________________________________ Número de serie:, Nombre d'ordre 2
Краткое содержание страницы № 3
SAFETY GUIDELINES / DEFINITIONS It is important for you to read and understand this manual. The information it contains relates to protecting YOUR SAFETY and PREVENTING PROBLEMS. The symbols below are used to help you recognize this information. indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. indicates a potentially hazardous s
Краткое содержание страницы № 4
GENERAL SAFETY RULES Fig. 1 1. Read and understand tool labels and manual. Failure to follow warnings could result in DEATH or SERIOUS INJURY. Fig. 1. Fig. 2 2. Operator and others in work area MUST wear safety glasses with side shields. These safety glasses must conform to ANSI Z87.1 requirements (approved glasses have “Z87” printed or stamped on them). Fig. 2. 3. Keep fingers AWAY from trigger when Fig. 3 not driving fasteners to avoid accidental firing. Never carry tool with finger on trigge
Краткое содержание страницы № 5
9. Do not connect tool to pressure which potentially exceeds 200 PSI (13.7 BAR). 10. All air line components (hoses, connectors, filters, regulators, etc.) must be rated for a maximum working pressure of at least 150 PSI (10.3 BAR) or 150% of the maximum system pressure, which ever is greater. 11. Connect tool to air supply hose with a Fig. 7 coupling that automatically removes all pressure from the tool when the coupling is Fig. 8 disconnected. Fig. 7. 12. Disconnect tool from air supply hose b
Краткое содержание страницы № 6
21. Remove finger from trigger when not Fig. 14 driving fasteners. Never carry tool with finger on trigger. In “Contact Actuation Mode” tool will fire a fastener if safety is bumped while trigger is depressed. Fig. 14. 22. Do not overreach. Keep proper footing and balance at all times when using or handling the tool. 23. Fire fasteners into work surface only: never into materials too hard to penetrate. Fig. 15 Fig. 15. 24. Grip tool firmly to maintain control while allowing tool to recoil away
Краткое содержание страницы № 7
EMPLOYER’S RESPONSIBILITIES Employer must enforce compliance with the safety warnings and all other instructions contained in this manual. Keep this manual available for use by all people assigned to use this tool. For personal safety and proper operation of this tool, read and understand tool labels and manual. Failure to follow warnings could result in DEATH or SERIOUS INJURY. Read and follow all of these instructions carefully. FUNCTIONAL DESCRIPTION Delta Model DBN125 is designed to install
Краткое содержание страницы № 8
PREPARING THE TOOL 1. After reading and understanding this entire manual, connect tool to air supply (Fig. 18). 2. Depress latch and slide magazine cover open (Fig. 19). 3. Insert a strip of approved fasteners (Fig. 20 and/or Fig. 20A). Orient fasteners with points down in the magazine. NOTE: Brad nails are side loaded and staples are top loaded. 4. Push magazine cover closed (Fig. 21). 5. Observe the low fastener indicator (A) Fig. 22 and reload as needed. 6. Adjust directional exhaust deflec
Краткое содержание страницы № 9
OPERATING INSTRUCTIONS USING THE TOOL Complete all steps of PREPARING THE TOOL before using the tool. This tool is shipped from the factory with a “single sequential actuation” trigger. To fire, grip the tool firmly to maintain control, position nose of tool onto work surface, push the tool firmly against work surface to depress safety (S) Fig. 24, and squeeze trigger to fire a fastener. Allow tool to recoil away from work surface as fastener is driven. This “single sequential actuation” method
Краткое содержание страницы № 10
The depth to which a fastener is driven is controlled by the depth adjustment knob (A) Fig. 25. The depth of drive is factory adjusted to a nominal setting. Test fire a fastener and check depth. If a change is desired, rotate the 1 adjustment knob (A) Fig. 25. The adjustment knob has detents every /4 turn. Rotate the knob (A) Fig. 25 clockwise to increase the depth of drive, rotate the knob counterclockwise to decrease the depth of drive. Test fire another fastener and check depth. Repeat as ne
Краткое содержание страницы № 11
CLEARING A JAMMED FASTENER Disconnect tool from air supply. 1. Open magazine and remove remaining fasteners (Fig. 28 and Fig. 29). Remove fasteners from tool before opening the fastener guide plate. Fasteners are under pressure and may shoot out of magazine which could cause injury. 2. Open the quick release latch and the fastener guide plate (Fig. 30). 3. Remove the jammed fastener (Fig. 31). 4. Close the fastener guide plate, and the quick release latch. Fig. 28 Fig. 29 Fig. 31 Fig. 30 11
Краткое содержание страницы № 12
MAINTENANCE CLEAN AND INSPECT DAILY Disconnect tool from air supply before cleaning and inspection. Correct all problems before placing the tool back in use. Wipe tool clean and inspect for wear or damage. Use non-flammable cleaning solutions to wipe exterior of tool only if necessary. DO NOT SOAK tool with cleaning solutions. Such solutions can damage internal parts. Inspect trigger and safety mechanism to assure system is complete and functional: no loose or missing parts, no binding or sticki
Краткое содержание страницы № 13
TROUBLESHOOTING Disconnect tool from air supply before performing any Service Procedure. SYMPTOM PROBLEMS SOLUTIONS 1. Air leak near top of Loose screws. Tighten screws. tool or in trigger area. Worn or damaged Install Overhaul Kit. o-rings or seals. 2. Tool does nothing or Inadequate air supply. Verify adequate air supply. operates sluggishly. Inadequate lubrication. Put 5 or 6 drops of oil into air inlet. Worn or damaged Install Overhaul Kit. o-rings or seals. 3. Air leak near bottom Lo
Краткое содержание страницы № 14
ACCESSORIES A complete line of accessories is available from your Porter-Cable Delta Supplier, Porter-Cable Delta Factory Service Centers, and Delta Authorized Service Stations. Please visit our Web Site www.deltamachinery.com for a catalog or for the name of your nearest supplier. Since accessories, other than those offered by Porter- Cable Delta, have not been tested with this product, use of such accessories could be hazardous. For safest operation, only Porter-Cable Delta recommended
Краткое содержание страницы № 15
PORTER-CABLE DELTA SERVICE CENTERS (CENTROS DE SERVICIO DE PORTER-CABLE DELTA) (CENTRE DE SERVICE PORTER-CABLE DELTA) Parts and Repair Service for Porter-Cable Delta Power Tools are Available at These Locations (Obtenga Refaccion de Partes o Servicio para su Herramienta en los Siguientes Centros de Porter-Cable Delta) (Locations où vous trouverez les pièces de rechange nécessaires ainsi qu’un service d’entretien) ARIZONA GEORGIA MINNESOTA Cleveland 44125 Tempe 85282 (Phoenix) Forest Pa