Краткое содержание страницы № 1
®
INSTALL GUIDE
ICEMAKER SERIES
BI2115 WH95
ADA15IM BI98
SS1095
SP18 SS98 BI95
The Built-In Undercounter Leader Since 1962 ULINE.COM
Краткое содержание страницы № 2
1 Table of Contents Safety Precautions Safety Alert Definitions.........................................................................................................................................2 General Precautions..............................................................................................................................................2 Inspect & Plan Product Registration ...................................................................................................
Краткое содержание страницы № 3
2 Safety Precautions General Precautions Use this appliance for its intended purpose only and follow these IMPO IMPOR RT TANT ANT general precautions with those listed throughout this guide: • PLEASE READ all instructions before installing, operating, or servicing the appliance. DANGER RISK OF CHILD ENTRAPMENT. Before you throw away your • Proper installation procedures must be followed when old refrigerator or freezer, take off the doors and leave shelves completing an installation or relo
Краткое содержание страницы № 4
Tools / Material Required 3 Inspect & Plan • Screwdrivers — slotted and Phillips head • 1/4-inch thick door panel material and cutting tools (If installing a 1/4” Panel) • 1/4” Nut Driver • 5/16” Nut Driver Product Registration • Side Cutter You have received a carton containing your ice maker unit with a • Copper tubing cutter package inside containing a Use and Care Guide, a Product Registration Card, and a water line kit. Please complete and mail • 12” Level the Product Registration Card
Краткое содержание страницы № 5
BI-98 / SS-98 Models 4 Prepare Site Filler Panel (Not Provided by U-Line) – May Be Added Above or Below Unit Your U-Line product has been designed for either free-standing or to Enclose for a Built-In Look built-in installation. When built-in, your unit does not require additional air space for top, sides or rear. However, the front grille must NOT be obstructed and clearance is required for an electrical and water connection in the rear. IMPO IMPOR RT TANT ANT Typical 21-1/2" Counter Units
Краткое содержание страницы № 6
SS-1095NF Models BCM95 Models Filler Panel (Not Provided by U-Line) – Filler Panel (Not Provided by U-Line) – May Be Added Above or Below Unit Needed to Attach Mounting Flange on Unit to Enclose for a Built-In Look Typical Counter 18-1/2”” Minimum Height 18-1/2" Minimum See Electrical 34-1/4" Specifications See Electrical to for Power Supply Specifications Cut-Out 35-1/8" for Power Supply Height Cut-Out 25-1/8” 8" Height Height From Floor 25-1/16" 8" 14-1/4" 3/4” 14-1/4” 3/4” Minimum Flange Cut
Краткое содержание страницы № 7
ADA15IM BI95 95TP BCM95 5 Product Dimensions ADA15IM Series BI95(B)(WH) BI2115 17” * 23”* 23-3/16" 25-1/16" 32” 34-1/8" 8-15/16” 13-15/16" 15” 3-13/16” *Add 1-1/2” For Water Line Clearance 15" *Add 5/8” For Water Line Clearance *Add 3/4” To Depth For Water Line Clearance BI95BTP BI2115 Stainless ADA15IM Stainless Series 17"* 17"* 23-1/8” 23”* 25-1/16" 25-1/16" 8 15/16” 15-1/8" 8 15/16” *Add 1-1/2” For For Water Line Clearance 15-1/8" 32” *Add 1-1/2” For For Water Line Clearance BI98 & SS98
Краткое содержание страницы № 8
SS1095 SP18 BCM95 WH95 SS1095NF SS1095FD SP18 15-1/8" 15-15/16” 17” * 26-1/16” 18-7/8" 7 9/16”" 9” 1/2" 24-1/2" * *Add 1 1/2” For Water Line Clearance SS1095FC *Add 1-1/2” For Water Line Clearance BCM95 15-1/8” 17” * 15-1/8" 17"* 25-1/8” 25-1/8" 9” 8 15/16” *Add 1 1/2” For Water Line Clearance *Add 1-1/2” For For Water Line Clearance SS1095NF WH95TP 17” * 14” 14" 17"* 25-1/16” 25-1/8" 9” 8 15/16” *Add 1-1/2” For For Water Line Clearance *Add 1 1/2” For Water Line Clearance Product Dimensions 7
Краткое содержание страницы № 9
Door Swing Dimensions 6 Other Site Requirements All units have a zero clearance for the door to open 90°. U-Line recommends a minimum door clearance of 2" to accommodate Power Supply the handle if the unit is installed next to a wall or similar type of structure. Units requires a grounded and polarized 115 VAC, 60 Hz, 15A circuit (normal household current). See Electrical Specifications on Page 14. Wall ADA15IM Series Wall Water Supply 1/4" Min. 2" Min. Units require a 1/4” OD water suppl
Краткое содержание страницы № 10
6. Remove plastic hole plug from door handle and relocate on 7 Door Reversal opposite side. See Figure 6. Hinge BI95 & BI98 Reversing the Door Plastic Plastic Plug Hole Plug Hole All units may be left- or right-hand opening. Note: The grille should not yet be installed. If it has been installed, remove it for door reversing. Screw To reverse the door: Right Side Left Side Door Swing Door Swing 1. Remove top hinge from cabinet (three screws). See Figure 1. Hold door to keep it from falling. Ri
Краткое содержание страницы № 11
6. Relocate plastic spacer/ WH95TP, BI95BTP, BCM95 & SP18 bushing on bottom of door to Reversing The Door opposite side, and place door on bottom hinge pin. See Bushing All units may be left- or right-hand opening. Figure 14. Clean out bushing To reverse the door: hole in door bottom with a screwdriver if necessary. 1. Remove travel pin from cabinet (two screws). See Figure 9. 7. Remove plastic travel pin Slide assembly through flange from door handle and and set aside to be used later.
Краткое содержание страницы № 12
7. Relocate plastic spacer/bushing (Figure 24) on top and bottom SS1095 of door to opposite side. Clean out bushing hole in door bottom Reversing the Door with a screwdriver if necessary. Depending upon the location of the unit, it may be desirable to 8. Using a Phillips screwdriver, remove the two screws holding the change the side on which the door is mounted. custom stainless handle from the original location, and remove the handle. Remove the two screws on the opposite side of the To r
Краткое содержание страницы № 13
28 13. Remove all three screws on the opposite side of the hinge and carefully lift off the door latch assembly (Figure 28). Figure 14. Place the door latch assembly on opposite side of unit ( 29 30 ). Be sure to tighten all three screws securely. 29 15. Place door on lower hinge pin. Invert and install upper hinge on door. Fasten upper hinge to unit (three screws (Figure 30). Partially tighten screws. 16. Adjust door to assure proper seal. Tighten upper and lower hinge screws securely. 17.
Краткое содержание страницы № 14
3. Remove the two outside screws holding 8 Door Panel Installation door handle. Slightly separate door handle from door. Door Panel Preparation 4. Pull handle up and off. BI-95, BI-2115B(WH), WH95BTP 5. Slide custom door panel insert into 1/4- A custom door panel may be inserted into the doorframe. Custom inch channel in door front. door panels can be flat or raised, as long as the maximum panel thickness, where inserted into the door reveal (channel), is no IMPO IMPOR RT TANT ANT more than
Краткое содержание страницы № 15
9 9 Adjust Door 10 Power Supply Electrical Specifications Checking Door Alignment The unit’s door is aligned at the factory before shipment. However, WARNING its alignment could have been disturbed during shipment. SHOCK HAZARD — Electrical Grounding Required. IMPO IMPOR RT TANT ANT • Never remove the round grounding prong from the Properly aligned, the door’s gasket should be firmly in plug and never use a two-prong grounding adapter. contact with the cabinet all the way around the door (no
Краткое содержание страницы № 16
9 IMPO IMPOR RT TANT ANT 11 Plumbing For units with front mounted water solenoids, route the water supply line through the unit so it does not come CAUTION into contact with any internal components other than the solenoid valve. Normal operation creates some vibration. Plumbing installation must observe all state and local A water supply line contacting an internal component or codes. All water and drain connections MUST BE made by cabinet wall can cause excessive noise during operation o
Краткое содержание страницы № 17
Installation 12 Install 1. Open the water supply valve in the main water source. Leveling Information 2. Plug in the powercord. ADA15IM & BI2115 3. Gently push the unit into position. Be careful not to kink the It is recommended that the unit is level. water supply line or entangle the electrical cord. 1. Use a level to check the 4. Re-check the leveling, from front to back and side to side. Make levelness of the unit from any necessary adjustments. The unit’s top surface should be front to
Краткое содержание страницы № 18
Installation Troubleshooting Problem Q: Water is leaking under the unit. Solution A: A water leak under the unit is most likely caused by a bad connection in the water supply line. Make sure the water line’s brass fitting is screwed tight to its valve and threaded correctly. Make sure that plumbers tape was NOT used; if it was remove all traces before reinstalling. BI-2115 Specific Problem Q: The door remains open unless it is pushed closed. Solution A: The hinges should be self-closing when
Краткое содержание страницы № 19
® INSTALLATION GUIDE SERVICE INFORMATION If you have a problem with this appliance, your use and care guide has troubleshooting information to help you quickly identify common problems and provide information on possible cause and remedy. Answers to Customers Frequently Asked Questions are available at www.u-line.com/customer/faq.cfm. You may contact U-Line directly: GENERAL INQUIRIES: SERVICE ASSISTANCE: U-Line Corporation Phone (800) 779-2547 P.O. Box 245040 FAX (414) 354-5696 Milwaukee,