Краткое содержание страницы № 1
E
S
R
U
A
M
N
U
A
L
Icemaker_UM_Cover.qxd 12/17/04 9:15 AM Page 1
™
Éc helon
P.O. Bo x 245040
Milwaukee, WI 53224-9540
Phone: 414.354.0300
Fax: 414.354.7905
www.u-line.com
Printed in U.S.A. P/N 30-10009 (Rev . 12/04)
Краткое содержание страницы № 2
Icemaker_UM_Cover.qxd 12/17/04 9:15 AM Page 2 U-LINE CORPORATION LIMITED WARRANTY U-Line Corporation warrants each U-Line product to be free from defects in materials and workmanship for a period of one year from the date of purchase; and warrants the sealed system (consisting of the compressor, the condenser, the evaporator, the hot gas bypass valve, the dryer and the connecting tubing) in each U-Line product to be free from defects in materials and workmanship for a period of five years fro
Краткое содержание страницы № 3
Body_UM.qxd 12/17/04 9:16 AM Page 1 INTRODUCTION Congratulations on your purchase of a U-Line CLR2060 Ice Maker. A pioneer in the field for more than 40 years, U-Line is the world’s num- ber one manufacturer of built-in, under-counter ice making and spe- cialty refrigeration products. U-Line dedicates 100% of its research and development to these products. The result: U-Line leads the mar- ket with innovation, design, depth of product line and performance. U-Line also backs customers with a s
Краткое содержание страницы № 4
Body_UM.qxd 12/17/04 9:43 AM Page 2 User’s Manual If you do not return your Product Registration Card, U-Line will use the date of sale to the U-Line distributor as the first date of warranty for your new ice maker. Please also record the purchase date of your U-Line unit and your dealer’s name, address and telephone number. Model Number: ________________________________________ Serial Number: ________________________________________ Purchase Date: ________________________________________ De
Краткое содержание страницы № 5
Body_UM.qxd 12/17/04 9:16 AM Page 3 SAFETY PRECAUTIONS Do not attempt to install or operate your unit until you have read the safety precautions in this manual. Safety items throughout this manual are labeled with a Danger, Warning or Caution based on the risk type. DEFINITIONS This is the safety alert symbol. It is used to alert you to ! potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. DANGER ! ! DANGER indicates an immine
Краткое содержание страницы № 6
Body_UM.qxd 12/17/04 9:16 AM Page 4 User’s Manual GENERAL PRECAUTIONS ! DANGER ! RISK OF CHILD ENTRAPMENT. Before you throw away your old refrigerator or freezer, take off the doors and leave shelves in place so that children may not easily climb inside. WARNING ! • Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected. •Altering, cutting of power cord, removal of power cord, removal of power plug, or direct wiring can cause serious injury, fir
Краткое содержание страницы № 7
Body_UM.qxd 12/17/04 9:16 AM Page 5 INSTALLATION DIMENSIONS 14-15/16" 24" (37.9) (61) 34-1/8" (86.7) 4.5" FULL (11.4) RETRACT HEIGHT WATER OUTLET WATER VALVE WATER 21-3/4" DRAIN (55.2) UL202 Figure 1 DRAIN INSTALLATION PLEASE READ all instructions completely before attempting to install or operate the unit. All Ice Makers require a con- nection to the water supply and improper hook-up can result in substantial property damage! All water and drain connections MUST BE made by a licensed/quali
Краткое содержание страницы № 8
Body_UM.qxd 12/17/04 9:16 AM Page 6 User’s Manual Follow these guidelines when installing drain lines to prevent water from flowing back into the ice maker storage bin and/or potentially flowing onto the floor causing water damage: Gravity Drain • Drain lines must have a 5/8" inside diameter. • Drain lines must have a 1" drop per 48" of run (1/4" per foot) and must not create traps. • The floor drain must be large enough to accommodate drainage from all drains. • Insulate the bin drain line t
Краткое содержание страницы № 9
Body_UM.qxd 12/17/04 9:16 AM Page 7 3. Remove 12 screws and back panel. 4. Check that the clamps and hose connections are tight at the fol- lowing areas: • Discharge tube (A) • Drain tube (B) • Vent tube (C) BB C A BACK VIEW SIDE VIEW UL184-2 5. Place a suitable container beneath the pump’s discharge tube. (The bucket must be able to hold a minimum of one gallon.) WARNING ! Back panel serves as a guard. DO NOT put your hands inside the ice maker cabinet or attempt to touch any com- ponents
Краткое содержание страницы № 10
Body_UM.qxd 12/17/04 9:16 AM Page 8 User’s Manual CONNECTING A DRAIN PUMP If a gravity drain connection is not available, and you have not pur- chased the CLR2060 with factory installed pump, we strongly rec- ommend the use of the U-Line P60 drain pump. The U-Line P60 drain pump is available through your Dealer, or direct from U-Line with com- plete installation instructions. If a pump other than the U-Line P60 drain pump is to be used, it must meet the following specifications: • It must be
Краткое содержание страницы № 11
Body_UM.qxd 12/17/04 9:16 AM Page 9 SITE PREPARATION 1. Position the unit on a flat, level surface, capable of supporting the entire weight of the unit. Remember that the unit will be signifi- cantly heavier once it is fully loaded. It is extremely important that the unit is level. If it is not level, the ice mold will not fill evenly. This can cause a reduc- tion in ice rate, uneven sized cubes or water spilling into the storage area which will cause the ice in the bin to melt pre- maturely.
Краткое содержание страницы № 12
Body_UM.qxd 12/17/04 9:16 AM Page 10 User’s Manual ! DANGER ! ELECTROCUTION HAZARD! Electrical Grounding Required. This appliance is equipped with a three prong (grounding) polarized plug for your protection against possible shock hazards. It must be plugged into a properly grounded three-prong receptacle. • NEVER remove the round grounding prong from the plug. •NEVER use a two-prong grounding adapter. •NEVER use an extension cord to connect power to the unit. Where a two-prong wall receptac
Краткое содержание страницы № 13
Body_UM.qxd 12/17/04 9:16 AM Page 11 8. Install and connect the water supply line. See CONNECTING THE WATER SUPPLY for installation requirements. 9. Position the unit to allow free air flow through the front grille (see Figure 3). INTAKE EXHAUST UL307A Figure 3 10. Wipe out inside of unit with a damp cloth. 11 O F F C L N I C E
Краткое содержание страницы № 14
Body_UM.qxd 12/17/04 9:16 AM Page 12 User’s Manual CONNECTING THE WATER SUPPLY When connecting the water supply, follow these guidelines: • Review the local plumbing codes before you install the unit. • In most instances, the cold water supply will come from the basement through a hole in the floor. • The water pressure should be between 20 and 120 psi. CAUTION If you are using a filter system you will need to have at least 20 psi for 3 minutes every 15 minutes. •Install a SHUT-OFF VALVE in t
Краткое содержание страницы № 15
Body_UM.qxd 12/17/04 9:16 AM Page 13 UL134 Figure 5 UL200 2. Carefully bend the water sup- ply line into position and con- Figure 7 nect the line to the solenoid valve (see Figure 6). Avoid NOTE kinking the water supply line. After completing the installation, turn on the water and recheck water and drain con- nection for leaks. Apply additional tightening if POWER needed. Do NOT use CORD thread sealing com- pound or tape. 4. Plug in the power cord. 5. Gently push the unit into posi- WATER
Краткое содержание страницы № 16
Body_UM.qxd 12/17/04 9:16 AM Page 14 User’s Manual LEVELING THE UNIT NOTE It is extremely important that the unit is level. If it is not level, the ice mold will not fill evenly. This can cause a reduc- tion in ice rate, uneven sized cubes or water spilling into the storage area which will cause the ice in the bin to melt pre- maturely. Remember that floors near drains have a ten- dency to slope towards the drain. 1. Use a level to check the levelness of the ice maker from front to back and
Краткое содержание страницы № 17
Body_UM.qxd 12/17/04 9:16 AM Page 15 REVERSING THE DOOR All U-Line units (except Stainless Steel models) may be left or right hand opening. The door opening is easily reversed by moving the hinge hard- ware to the opposite side (see Figure 10). To reverse the door: UL318B Figure 10 1. Remove top hinge screw pin (7/64" Allen wrench) from cabinet (see Figure 11). Remove door by tilting forward and lifting off bottom hinge pin. UL310 Figure 11 15
Краткое содержание страницы № 18
Body_UM.qxd 12/17/04 9:16 AM Page 16 User’s Manual 2. Remove plastic screw plugs 4. Remove the two door closer (3 each, top and bottom) inserts from the existing from new hinge location. Do bottom hinge and install as not discard (see Figure 12). shown on the new bottom hinge (see Figure 14). SCREW PLUGS DOOR CLOSERS UL308 Figure 12 BOSS 3. Remove top hinge (3 screws), UL312 reinstall hinge screw pin, and remount on opposite side Figure 14 BOTTOM (see Figure 13). 5. Remove existing bottom hi
Краткое содержание страницы № 19
Body_UM.qxd 12/17/04 9:16 AM Page 17 UL319 Figure 15 7. Holding door upright with top of door tilted forward, place hole of door pivot plate on bottom hinge screw pin (see Figure 16). Be sure that the bosses on the closers align with holes in hinge and hinge plate. 8. Tilt top of door into position in top hinge and install top hinge screw pin. 9. Install plastic screw plugs BOSS removed in Step 2 in old hinge holes (3 each, top and bottom). CLRCO008 Figure 16 17
Краткое содержание страницы № 20
Body_UM.qxd 12/17/04 9:16 AM Page 18 User’s Manual DOOR ADJUSTMENT Your door is aligned at the factory before shipment. Occasional re-adjustment may be necessary, especially if an Overlay Panel is installed. The following procedure will correct for up to 1/4" alignment. The door should never be flush with the top of the cabinet. Even when level, the top edge of the door will be 1/8" below the top of the cabinet (Figure 17). To adjust : 1. Compare the top edge of 1/8" the door (opposite the h