Краткое содержание страницы № 1
owner’S Manual
arp-5010X, 5012X, 5012XH
portable air conditioner
arp- 5010X, 5012X, 5012XH
portable air conditioner
acondicionador de aire portÁtil
Read and retain these instructions for future reference
For any customer Support needs, please choose
the Support tab on www.royalsovereign.com
Royal Centurian Inc.
Краткое содержание страницы № 2
portable air conditioner Model ARP-5010X, 5012X, 5012XH introduction Thank you for choosing Royal Sovereign to provide you and your family with all of the “Home Comfort” requirements for your home, apartment, or office. This Portable Air Conditioner can be set-up in just minutes and can be easily moved from room to room. It is a multi-functional room air comfort system that offers you Air Conditioning, Dehumidification and Air Circulation modes. This manual will provide you with valuable i
Краткое содержание страницы № 3
contentS Page Precautions for use∙ ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 4 Notes on operation and identification of parts ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 5 Installation instructions ∙ ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 6~7 Operation ∙ ∙∙∙∙∙
Краткое содержание страницы № 4
precautionS For uSe electrical Specifications and power cord Check to ensure that the electrical service being used is adequate for the model you’ve chosen. The electrical rating of your new air conditioner is defined on the serial plate of the unit. Please refer to the rating when checking electrical requirements to ensure they meet the electrical codes of your location. • ∙In stal l∙th e∙ai r∙con di ti on er∙accordi n g∙to ∙th e∙i n stall ati on∙i n str u cti on s∙su ppl i ed. • ∙Do∙n ot∙m
Краткое содержание страницы № 5
arp-5010X, 5012X, 5012XH noteS on operation If you turn the air conditioner off and immediately restart it, allow 3 minutes for the compressor to restart cooling. In the event of a power failure, wait 3 minutes before restarting unit. identiFication oF partS 1. Air outlet 2. Display panel ➀ 3.∙A i r∙i n take∙( ev apor ator) ➁ 4. Air inlet hose ➄ 5. Air filter ➂ 6.∙A i r∙ou tl et∙h ose( h eat∙e xch ang e) 7. Water outlet drain ➅ ➃ 8. Caster 9. Power supply cord ➇ ➆ ➈ 5
Краткое содержание страницы № 6
inStallation Unpack your New Portable Air Conditioner and let the machine stand upright for 2 hours before starting. Unpack all parts listed below. If any parts are missing do not return this product to the place of purchase. Please visit our website www.royalsovereign.com and click on the “Customer Support” tab and ➁ ➅ “Make a Request” to request missing parts or call 1-800-397-1025 and press option #4 to order these parts. ➃ accessories include ➃ ➄ 1. Window slider kit∙ ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙
Краткое содержание страницы № 7
arp-5010X, 5012X, 5012XH c. install the window Slider Kit : Fig 3. 1. Open the window and place the window slider kit on the inside edge of the window. 2. Adjust the window slider by adjusting it to the width of the window. 3. Close the window to secure. 4. Tighten the four screws to lock the window slider in place. Fig 3. d. connecting the exhaust Hose to the pac : Fig 4. 1. Connect the hose connector to the air outlet by aligning the tabs on the hose to the PAC and snap it into place. 2.
Краткое содержание страницы № 8
operation indication Symbols on lcd display Warning Light LCD display Timer control Timer/ Temperature set control Cooling mode High fan speed control panel Dehumidify mode Med fan speed Fan only mode Low fan speed ∙Heati n g∙mode∙( on l y∙A RP-5012X H) Display set temperature Warning light the machine will stop running Fan speed control Power control Display timer setting of auto switch on/off Mode control power control The power control turns the unit on and off. When you press the co
Краткое содержание страницы № 9
arp-5010X, 5012X, 5012XH Heat Mode (only arp-5012XH) Press the Mode button to select Heat mode. When in Heat mode the symbol will show on the display. During operation, the unit displays “present room temperature”. Heating is only activated when the temperature in the room is below 81°F. The temperature setting can be adjusted between 61 and 81° F. A. In Heat mode, use the “+” or “-” button to adjust and set the desired temperature for the room. After 10 seconds the display will return bac
Краткое содержание страницы № 10
r emote control indication Symbols on lcd display All functions can be accessed from the remote control. Cooling mode High fan speed Dehumidify mode Med fan speed Fan only mode Low fan speed LCD Display Power On/Off ∙Heati n g∙mode∙( on l y∙A RP-5012X H) Display set temperature Warning light the machine will stop running Timer/Temp Control Set Button Display timer setting of auto switch on/off A/C Fan Speed timer (High,∙Medium,∙Low) There are 2 different timer programs. You can set th
Краткое содержание страницы № 11
arp-5010X, 5012X, 5012XH r emote control operation -∙T h e∙r emote∙con trol∙u ses∙two∙∙A A A ∙( IE C∙RO# ∙1.5V)∙batteries∙wh i ch∙h ave∙been∙i n cl u ded∙f or∙y ou r∙con ven i en ce. - Remove the battery cover on back of the remote. -∙In ser t∙th e∙batteri es ,∙maki n g∙su r e∙th e∙( + )∙an d∙( -)∙pol ari ty∙i s∙al i gn ed∙cor r ectl y . - Replace the battery cover. notes: -When replacing batteries, always change both batteries at the same time. -Remove the batteries if the remote control is n
Краткое содержание страницы № 12
Maintenance drainage Occasionally, you may need to drain the unit. 1. Drain the unit if the Warning Light on the display panel of the air conditioner is on. 2. Turn off the power to the unit and unplug. 3. Place a shallow dish under the drainage plug to collect water. 4. Remove the drainage plug. 5. Replace the plug, when drainage water stops flowing. cleaning the filter The filter should be cleaned every 2 weeks or 100 hours of use in order to maintain proper airflow. 1. Remove the filter. Gen
Краткое содержание страницы № 13
arp-5010X, 5012X, 5012XH troubleSHootinG problem possible r easons - Check and reset the power plug. Wait 3 minutes and try to run the unit again. - The batteries in the remote may need to be replaced. Replace the batteries and try to run the unit again. Air Conditioner does not operate - Make sure the plug is properly plugged into the outlet. - The set temperature may be too close to room temperature. Lower the set temperature. - The air outlet may be blocked. Check the air outlet and remov
Краткое содержание страницы № 14
SpeciFicationS - Figures noted in the contents are for reference only; variation may result due to the application in different countries or regions, and shall be based on practical operation. description of product air conditioner ARP-5012XH Model ARP-5010X ARP-5012X Cooling Heating V ol tag e/F r equ en cy A C∙115V~60Hz Input power 950W 1200W 1000W 1200W Current 8.7A 10.5A 10.5A 8.5A Cooling Capacity 10,000BTU/hr 12,000BTU/hr 12,000BTU/hr Dehumidifying Capacity 3.8 pints/hour 4.2 pints/hour
Краткое содержание страницы № 15
arp-5010X, 5012X, 5012XH Full one Year warrantY Royal Sovereign warrants each Portable Air Conditioner to be free from defects in material and workmanship. Our obligation under this warranty is limited to the repair or r epl acemen t,∙fr ee∙of ∙ch ar g e,∙wh en∙del iver ed∙to ∙an∙au th ori zed∙R o yal∙S o ver eign∙ser vi ce∙cen ter ,∙of ∙an y∙defective∙par t( s)∙th er eof ,∙oth er∙th an∙par ts∙damag ed∙i n∙tr an si t.∙T h i s∙war r an ty∙i s∙ in effect to the original purchaser, for a period of
Краткое содержание страницы № 16
ro Yal SoVereiGn international , inc. rS international auStralia ptY. ltd . rS Holland b .V. 2∙V ol vo∙Drive ∙R ockl ei gh ,∙NJ∙07647∙US A 30 Prime Drive, Seven Hills, NSW 2147, AUSTRALIA Industrieweg 6K, 4104AR, Culemborg, The Netherlands TE L∙:∙+ 1)∙800-397-1025∙∙∙∙∙∙∙∙F A X∙:∙+ 1)∙201-750-1022 TE L ∙∙:∙+ 61)∙2-9674-2127∙ F A X∙∙:∙+ 61)∙2-9674-2027 T el :∙+ 31∙( 0) 345∙473∙097∙∙∙∙F ax:∙31∙( 0) 345∙519∙811 ro Yal SoVereiGn inc. rS canada inc. r oyal Sovereign Mexico, S.a. de c.V. 1001, World Me
Краткое содержание страницы № 17
Español Manual del propietario arp-5010X, 5012X, 5012XH acondicionador de aire portÁtil arp- 5010X, 5012X, 5012XH acondicionador de aire portÁtil Lea y guarde estas instrucciones para referencia en el futuro. para Servicio al cliente por favor diríjase a nuestra página web www.royalsovereign.com y seleccione “Support tab” Royal Centurian Inc.
Краткое содержание страницы № 18
acondicionador de aire portÁtil Modelo ARP-5010X, 5012X, 5012XH introducción Gracias por escoger Royal Sovereign para proveerle a usted y a su familia lo requerido para tener esa “Comodidad de Hogar” en su casa, departamento u oficina. Este acondicionador de aire portátil puede ser instalado en sólo minutos y fácilmente transportado de habitación a habitación. Es un sistema de cómoda ventilación multi-funcional que le ofrece modos de Aire Acondicionado, Deshumedecedor y Circulación de Aire. E
Краткое содержание страницы № 19
contenido Página Precauciones de Uso ∙ ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 20 Notas Sobre el Funcionamiento e Identificación de las Partes∙ ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 21 Instrucciones para la Instalación ∙ ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 22~23 Funcionamiento ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙
Краткое содержание страницы № 20
precaucioneS de uSo especificaciones eléctricas y cable de electricidad V eri fi qu e∙qu e∙el∙ser vi ci o∙el éctri co ∙en∙u so∙es∙el∙adecu ado ∙par a∙el∙model o∙qu e∙h a∙el egi do .∙E l∙vol taj e∙el éctri co∙de∙su∙n u evo∙acon di ci on ador∙de∙ai r e∙está∙ descrito en la placa de serie de la unidad. Por favor, revise el voltaje eléctrico cuando verifique los requerimientos eléctricos para asegurarse de que correspondan a los códigos de electricidad de su localidad. • ∙In stal e∙el∙acon di ci on