Краткое содержание страницы № 1
THE PROFESSIONAL SIDE BURNER
Use and Care Guide
MODELS:
BGB131
BGB132
BGB131-BI
BGB132-BI
Краткое содержание страницы № 2
A MESSAGE TO OUR CUSTOMERS We are glad that you selected the Professional Side Burner by DCS. Because this appliance contains features not found on any other burner, we recommend that you read this entire booklet before your first use. Keep it in a handy place as it has answers to questions that may occur during future use. Feel free to contact us if we can help you. When you write please include the model serial number of the Burner. We thank you for buying the Made in America Side Burner and w
Краткое содержание страницы № 3
TABLE OF CONTENTS SAFETY PRACTICES AND PRECAUTIONS ..................................................................................................3-4 SIDE BURNER 131/132 SIDE MOUNT MODEL INSTALLATION...................................................4-5 SIDE BURNER BUILT-IN MODEL INSTALLATION....................................................................................6-7 GAS REQUIREMENTS Natural Gas Hook-up................................................................................
Краткое содержание страницы № 4
SAFETY PRACTICES & PRECAUTIONS Improper use or installation is dangerous. Carefully follow these instructions. Always remove the cover before lighting the Professional Side Burner. Never use the Side Burner if a leak is present. Do not use a flame to check for gas leaks. Do not let children use the Professional Side Burner. Do not leave children unattended near the Side Burner. Never let children crawl or hang on the Side Burner. Exercise care when operating the Professional Side Bur
Краткое содержание страницы № 5
SAFETY PRACTICES & PRECAUTIONS SPIDER AND INSECT WARNING! Spiders and insects can nest in the burner(s) or orifices of this or any other gas appliance, and can block or restrict the burner. This can cause a flash back to the control panel. This is a very dangerous condition which can cause a fire to occur, thereby damaging the unit and making it unsafe to operate. You must inspect the burner(s) at least once a year or immediately if any of the following conditions occur: 1. The smell of gas in
Краткое содержание страницы № 6
SIDE BURNER 131/132 SIDE MOUNT MODEL INSTALLATION 15 -3/4" 26-3/4" 10-3/8" 10-3/8" " " 2 12- 3/4 " 2 23- 3/4" IGNITION BURNER REAR IGNITION FRONT - 10 3/8" - 10 3/8" " 13 " 13 Standard construction MODEL A BGB131 12-7/8" BGB132 23-7/8" 13-1/8" A 10 - 1/4" 2" X 2" opening for gas supply line 5
Краткое содержание страницы № 7
SIDE BURNER BUILT-IN MODEL INSTALLATION INSTALLATION OF SIDE BURNER BUILT-IN: 6" All BGB131-BI and BGB132-BI models can be min. installed in combustible enclosure with zero clearance from the back, side and bottom. A minimum of 6” from the back and sides must be maintained from the Professional Side Burner above the cooking surface to combustible construction (see Fig. 02). When determining a suitable location, take into account concerns such as exposure to wind, proxim- ity to traffic paths,
Краткое содержание страницы № 8
SIDE BURNER BUILT-IN MODEL INSTALLATION Single Side Burner Dual Side Burner 14 -3/4" 25-1/2" 10-1/16" 10-1/16" " " 2 11- 3/4" 2 22- 1/8" 25- 1/2" Standard construction 12" MODEL A A BGB131-BI 12" BGB132-BI 22-3/8" 2" X 2" opening 10-1/16" for gas supply line note: the deck is not required 7
Краткое содержание страницы № 9
GAS REQUIREMENTS GAS REQUIREMENTS: Verify the type of gas supply to be used, either natural or LP. Make sure the marked gas on the appliance rating plate(s) and hook-up kit agrees with that of the supply. Never connect an unregulated gas line to the appliance. An installer supplied gas shut-off valve must be installed in an easily accessible location. All installer supplied parts must conform to local codes, or in the absence of local codes, ANSI/NFPS-770-1984. All pipe sealants must be an appr
Краткое содержание страницы № 10
GAS REQUIREMENTS To hook-up the fittings supplied with the Professional Side Burner, assemble as shown in Fig.03. Use joint compound on male Bottom of 131 &132 Burner threads only. Open Top Do not use joint compound on the flare end of Manifold the 1/2” NPT to 3/8” flare adapter. Ensure that 1/2" Coupling the regulator arrow points in the direction of 1/2" Nipple gas flow-towards the unit, away from the supply. Regulator Do not forget to place the installer-supplied 1/2" Nipple gas valve in an
Краткое содержание страницы № 11
LEAK TESTING & LIGHTING INSTRUCTIONS WARNING: Do not smoke while leak testing. Extinguish all open flames. Make a soap solution of one part liquid detergent, and one part water. Never test for leaks with an open flame. For LP units, check with a full cylinder. Make sure all control valves are in the “OFF” position. Turn the gas supply “ON”.Check all connections from the supply line (Fig. 02), or LP cylinder (Fig. 03) up to the manifold pipe assembly (Fig. 05). Apply the soap solution around the
Краткое содержание страницы № 12
LIGHTING INSTRUCTIONS MATCH LIGHTING Hold a fireplace lit match near the burner ports, turn the control knob counterclockwise to “HI”.Move your hand immediately once the burner is lit. Rotate the control knob to the desired setting. Note: If you are using propane gas, a slight pop or flash may occur at the burner Cap ports a few seconds after the burner has been turned “off”. This “extinction pop” is normal for propane gas. BURNERS Your new side burner is equipped with burners typical of those
Краткое содержание страницы № 13
FINAL CHECKLIST Specified clearances maintained to combustibles. Professional Side Burner is properly mounted. All internal packaging removed. Burner is seated properly and does not rock. Each burner lights satisfactorily, individually or with adjacent burner lit. Knob(s) turn freely. Bezel(s) centered. Flame adjusted. Pressure regulator connected and set for 4.0"W.C. Natural, 11.2"W.C. LP gas. Manual shut-off valve installed and accessible. Unit tested and free of leaks. U
Краткое содержание страницы № 14
GENERAL CLEANING BURNERS For proper lighting and performance keep the burners clean. It is necessary Cap to clean the burners if they do not light even though the igniter clicks, if there has been a severe boil over, or when the flame does not burn blue. Be Brass Ring Main certain all burner knobs are in the off Locating Pins Burner position before attempting to clean the Port burners. The burners have been Ring designed for ease in cleaning. When the grate and burners are cool, remove the grat
Краткое содержание страницы № 15
TROUBLESHOOTING PROBLEM WHAT TO DO Burner won’t light when the ignition Remove the burner grate. With the control knob in the “OFF” is pushed. position, listen to the electrode while engaging the ignition. You should hear a spark jump inside the electrode cap.When the spark jumps, it makes a ticking sound. If there is no spark........ Could be a dead battery. Or the air gap between an electrode tip and a contact metal is too far (gap should be 1/8”) or dirty. If there is a spark... is there gas
Краткое содержание страницы № 16
SINGLE SIDE BURNER PARTS LIST FOR BGB131 & BGB131-BI 1 5 6 3 7 4 2 8 9 29 30 31 24 25 23 22 10 11 21 26 20 19 27 18 17 12 28 13 14 16 15 NOTE: Part list typical for BGB131 & BGB131-BI models. Illustration shows BGB131-BI model. ITEM DESCRIPTION PART NO. ITEM DESCRIPTION PART NO. 1BURNER COVER 33316 15 BEZEL 14006-PL 2PULL HANDLE 18204-01 16 CONTROL KNOB 14351 3RUBBER BUMPER 18403 17 IGNITION MODULE 16566 4TOP GRATE BK 12020 18 WIRE BLACK W/ TERMINALS 8” 16438-0
Краткое содержание страницы № 17
DOUBLE SIDE BURNER PARTS LIST FOR BGB132 & BGB132-BI 4 5 6 7 1 8 9 30 3 31 25 32 24 2 26 21 10 23 11 20 27 22 19 28 12 18 17 29 16 15 14 13 NOTE: Part list typical for BGB132 & BGB132-BI models. Illustration shows BGB132-BI model. ITEM DESCRIPTION PART NO. ITEM DESCRIPTION PART NO. 1BURNER COVER 33299 16 CONTROL KNOB 14351 2PULL HANDLE 18204-01 17 IGNITION MODULE 16566 3RUBBER BUMPER 18403 18 WIRE BLACK W/ TERMINALS 10” 16438-06 4TOP GRATE BK 12013-1 19 WIRE BL
Краткое содержание страницы № 18
SINGLE & DOUBLE SIDE BURNER WIRING DIAGRAM SINGLE SIDE BURNER SPARK ELECTRODE (P/N 12224) GND (Switch is built into module) BATTERY TERMINAL IGNITION MODULE DOUBLE SIDE BURNER 1.5 VOLT (P/N 16566) ALKALINE BATTERY P/N 16567) SPARK ELECTRODE (P/N 12224) SPARK ELECTRODE (P/N 12224) (Switch is built into module) TERMINAL BATTERY IGNITION MODULE NOTE: HIGH VOLTAGE AT TERMINALS (P/N 16566) 17
Краткое содержание страницы № 19
WARRANTY LENGTH OF WARRANTY DCS warrants all other Side Burner components parts and labor to the original purchaser to be free of factory defects in material and workmanship for a period of one (1) year from the original date of purchase. This does not apply if the unit was subjected to other than normal residential use. Limited Five (5) year parts only covers burner(s), the structural integrity of the exterior and interior body parts. Should rusting occur to the degree of non-performance, repla
Краткое содержание страницы № 20
SERVICE HOW TO OBTAIN SERVICE: For warranty service, please contact your local service provider or DCS Customer Care Center at (888) 281-5698, Monday thru Friday, 6 am- 4:30 pm PST. Before you call, please have the following information ready: Model Number (located on the inside of the left side of the appliance) Serial Number (located on the inside of the left side of the appliance) Gas Type Date of installation A brief description of the problem Your satisfaction is of the utmost im