Краткое содержание страницы № 1
OPERATING INSTRUCTIONS FOR
Model 7600
NDIR Infrared Gas Analyzer
P/N M7600
ECO:
DANGER
Toxic gases and or flammable liquids may be present in this monitoring system.
Personal protective equipment may be required when servicing this instrument.
Hazardous voltages exist on certain components internally which may persist
for a time even after the power is turned off and disconnected.
Only authorized personnel should conduct maintenance and/or servicing.
Before
Краткое содержание страницы № 2
Model 7600 Copyright © 2005 Teledyne Instruments/ Analytical Instruments All Rights Reserved. No part of this manual may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any other language or computer language in whole or in part, in any form or by any means, whether it be electronic, mechanical, magnetic, optical, manual, or otherwise, without the prior written consent of Teledyne Instruments/ Analytical Instruments, 16830 Chestnut Street, City
Краткое содержание страницы № 3
Infrared Gas Analyzer Specific Model Information Instrument Serial Number: _______________________ Instrument Range: _______________ Calibrated for: _______________ Background Gas: _______________ Zero Gas: _______________ Span Gas: _______________ Teledyne Analytical Instruments iii
Краткое содержание страницы № 4
Model 7600 Safety Messages Your safety and the safety of others is very important. We have provided many important safety messages in this manual. Please read these messages carefully. A safety message alerts you to potential hazards that could hurt you or others. Each safety message is associated with a safety alert symbol. These symbols are found in the manual and inside the instrument. The definition of these symbols is described below: GENERAL WARNING/CAUTION: Refer to the instru
Краткое содержание страницы № 5
Infrared Gas Analyzer IF YOU USE THE ANALYZER IN A MANNER OTHER THAN THAT FOR WHICH IT WAS INTENDED, UNPREDICTABLE BEHAVIOR COULD RESULT POSSIBLY ACCOMPANIED WITH HAZARDOUS CONSEQUENCES. This manual provides information designed to guide you through the installation, calibration operation and maintenance of your new analyzer. Please read this manual and keep it available. Occasionally, some instruments are customized for a particular application or features and/or options added pe
Краткое содержание страницы № 6
Model 7600 Table of Contents List of Figures ............................................................................... x List of Tables............................................................................... xii Introduction ................................................................................. 15 1.1 Overview 15 1.2 Main Features of the Analyzer 15 1.3 Options Available 17 1.4 Applications 17 1.5 Description of the Main Unit 18 Installation ...............
Краткое содержание страницы № 7
Infrared Gas Analyzer Operation .....................................................................................35 3.1 General Information 35 3.2 Display and Available Menus 36 3.3 The Display Screen 38 3.3.1 Measurement Mode 38 3.3.2 Setting/Selection Screen 40 3.4 Basic Operation 41 3.5 Setting Up the Analyzer in the User Mode 42 3.5.1 Switch Ranges 42 3.5.1.1 Manual Range Switching 43 3.5.1.2 Range identification contact operation 44 3.5.1.3 Remote Range Selection 45 3.
Краткое содержание страницы № 8
Model 7600 3.5.7.1 Output Hold 75 3.5.7.2 Average Value Reset: 78 3.5.7.3 Response Time 79 3.5.7.4 Average Period 79 3.5.7.5 Backlight Timer 80 3.5.7.6 Maintenance mode 81 3.6 Maintenance Mode 82 3.6.1 Sensor Input Value 83 3.6.2 Error Log 84 3.6.3 Calibration Log 84 3.6.4 Optical Adjustment 85 3.6.5 Moisture Interference Adjustment 86 3.6.6 Output Adjustment Screen 86 3.6.7 Other Parameters 87 3.7 Calibration 90 3.7.1 Zero Calibration 90 3.7.2 Span Calibration 91 Maintenanc
Краткое содержание страницы № 9
Infrared Gas Analyzer A.3 Optional Functions 115 A.4 Performance: 116 A.5 Standard Requirements for Sample Gas 117 A.6 Installation Requirements 118 A.7 EC Directive Compliance 118 A.8 Terminal Block Connections 119 A.9 Description on Terminal Block 120 Index...........................................................................................125 Teledyne Analytical Instruments ix
Краткое содержание страницы № 10
Model 7600 List of Figures Figure 1-1: Model 7600A Infrared Gas Analyzer........................... 16 Figure 1-2: Model 7600 Description .............................................. 19 Figure 2-1: Slide Rail Mounting Dimensions ................................. 23 Figure 2-2: Input/Output Terminal Module..................................... 24 Figure 2-3: Mounting the I/O Module............................................. 24 Figure 2-4: Internal Piping with Single or Dual Measuri
Краткое содержание страницы № 11
Infrared Gas Analyzer Figure 3-11: Output Hold for Auto Calibration ...............................76 Figure 3-12: Output Hold for External Hold ...................................76 Figure 3-13: Average Value Reset ................................................79 Figure 3-14: Example Average Period ..........................................80 Figure 4-1: Top Cover Removal ....................................................95 Figure 4-2: Sample Cell Removal.........................
Краткое содержание страницы № 12
Model 7600 List of Tables Table 2-1: Correspondence of Measured Components and Measuring Units ..................................................................... 27 Table 2-2: Zero and Span Gas...................................................... 29 Table 4.1 Troubleshooting and Maintenance ................................ 93 Table 4-2: Components of Optical Adjustment Screen ............... 100 Table 4-3: Error Messages.......................................................... 104
Краткое содержание страницы № 13
Infrared Gas Analyzer DANGER COMBUSTIBLE GAS USAGE WARNING This is a general purpose instrument designed for use in a non-hazardous area. It is the customer's responsibility to ensure safety especially when combustible gases are being analyzed since the potential of gas leaks always exist. The customer should ensure that the principles of operating this equipment are well understood by the user. Misuse of this product in any manner, tampering with its components, or
Краткое содержание страницы № 14
Model 7600 Teledyne Analytical Instruments xiv
Краткое содержание страницы № 15
Infrared Gas Analyzer Introduction Introduction 1.1 Overview The Model 7600 Infrared Gas Analyzer is a microprocessor based infrared gas analyzer used to measure the concentration of NO, SO , 2 CO , CO and CH contained in sample gas. It is based on the principle 2 4 that different molecular species have unique absorption spectrum in the infrared, and the intensity of absorption is determined by the Lambert- Beer law. In addition to the infrared analyzer, the Model 7600 can also be e
Краткое содержание страницы № 16
Introduction Model 7600 Figure 1-1: Model 7600A Infrared Gas Analyzer • Simultaneous measurement of up to five components • Excellent long-term stability • Large, easy to read LCD display showing all simultaneous measurements and computations • Slide-out, chassis design to facilitate any optical or maintenance adjustments required to fine tune analyzer performance (7600A) • Multiple, in-depth on-screen analyzer functions easily accessible using the front-panel user interface butt
Краткое содержание страницы № 17
Infrared Gas Analyzer Introduction • Instrument or calibration error contact outputs • Extra functions included such as average value computation, O conversion 2 • Pump ON/OFF contact 1.3 Options Available • Percent O detector — Paramagnetic (built-in) or ZrO 2 2 (externally installed), user preference • O correction (the conversion of measured CO and SO 2 2 readings into values at standard O concentration). Consult 2 factory for more detail for this function. • Communication fun
Краткое содержание страницы № 18
Introduction Model 7600 • Biochemistry and fermentation, • Automotive emission analysis • Explosive and toxic gas analysis • Chemical analysis • Refinery operation • Research applications 1.5 Description of the Main Unit Teledyne's Series 7600 Infrared Gas Analyzer measures the concentration of NO, SO , CO , CO, and CH in a gas mixture on a 2 2 4 continuous basis. The Series 7600 can also be supplied with an oxygen sensor, which allows the simultaneous measurement of oxygen concen
Краткое содержание страницы № 19
Infrared Gas Analyzer Introduction Figure 1-2: Model 7600 Description Gas connections for the 7600 instrument are made on the rear panel of the instrument using the ¼” NPT fittings installed. The standard instrument has two measuring units and a pair of inlet/outlet gas connections exist for each unit. See Section 2.5 Gas Connections. A power receptacle on the rear panel accepts the three-prong power cable supplied with the instrument. The Model 7600 operates on 100- 240 VAC 50
Краткое содержание страницы № 20
Introduction Model 7600 Teledyne Analytical Instruments 20