Краткое содержание страницы № 1
CAUTION: Read all instructions carefully before installation.
Save this Owner’s Manual for future reference.
Model Nos. HD7002 1 & HD7005 0
®
EMERSON
™
MoistAIR HD7002 & HD7005
Evaporative Console
Humidifier Owner’s Manual
Part No. SP6470 Printed in Canada
Краткое содержание страницы № 2
Limited Warranty All products covered by this Owner’s Manual are warranted against defects in workman- ship and materials for one year from the date of sale except for motors, which are war- ranted for two years. This warranty does not apply to damage from accident, misuse or alteration nor where the connected voltage is more than 5% above the nameplate volt- age, nor to equipment improperly installed or wired or maintained in violation of this Owner’s Manual. No other written or oral warranty a
Краткое содержание страницы № 3
Know Your Humidifier Fan Assembly Controls Bottle Cover Filter Support Assembly Filters Replacement No. HDC-2R or HDC411 NOTE: HDC411 provides two filter changes. Description HD7002 & HD7005 Gallon Output / 24 hrs 7 Litre Output / 24 hrs. 26.5 Capacity of Bottle 2.5 Gallons Capacity of Bottle 9.4 Litres * Sq. Ft. Coverage 1500 Fan Speeds 3 Number of Filters 2 Fill Light Yes Auto Humidistat Yes Auto Shut Off Yes Controls Rotary CUL Listed Yes Volts 120 A.C. Hertz 60 Amps 1.14 Watts 65 * Based on
Краткое содержание страницы № 4
Humidifier Operations Humidified Air is Your new Emerson humidifier is designed to Then Released satisfy home humidity requirements through Through the Top the principle of evaporation of water into the air. After water is added to the bottle and positioned in the humidifier, the filters Dry Air Enters begin to soak up the water and become Through the totally saturated in approximately 30 min- Rear utes. Air is drawn in from the rear of the humidifier and through the filters by means of one cir
Краткое содержание страницы № 5
Location Instructions WARNING: For your own safety, do next to an inside wall. Hot air registers not use humidifier if any parts are and cold air from outside walls can affect damaged or missing. the efficiencies of the controls. Unit should not be placed where warm air 1. Place humidifier on a flat level surface in from a hot air register blows directly on area of house where most humidity is unit. needed, or an area which would likely result in moist air being circulated 2. The humidifier shou
Краткое содержание страницы № 6
Water Fill (continued) Turn Counterclockwise To fill this humidifier, close the control cover to Remove “E-Z-Fill Side-Cap and remove the bottle cover. To remove the water bottle, lift the bottle straight up and out of the cabinet. The water bottle is designed with an “E-Z- Fill Side-Cap”. Remove the “E-Z-Fill Side- Cap” on the side of the water bottle by twist- ing counterclockwise. Place the opening of the water bottle under Valve Cap a water faucet (the bottle should fit under a Plunger four-
Краткое содержание страницы № 7
Operating Humidifier Controls The operating controls of your Emerson Fill Light evaporative humidifier are located on the When the unit has a small amount of water top right of the humidifier. The controls are left in it, the fill light will come on and found under the smoked cover the unit will automatically shut off. Lift the control cover by placing your finger in the round cutout and lifting. The cover will stay open. Now you can clearly see the con- trol area. Familiarize yourself with
Краткое содержание страницы № 8
y t i d i m u H . l e R y t i d i m Using Your Humidifier 1. Be sure unit is full of water and plugged 4. If humidifier stops running and the Fill in. Light is not illuminated, the humidity level is at the normal requirements for 2. Set air flow control to desired fan that setting or it is adjusting to the home speed. conditions. The table below shows rela- 3. Set Humidity Control to medium tive humidity percentages which are position (halfway between and ) ) recommended at
Краткое содержание страницы № 9
Replacement and Care of Filters Water Bottle Cover WARNING: To reduce the risk of shock or injury from moving parts, always unplug humidifier before removing or replacing any parts. CAUTION: To help retard bacteria growth and keep maximum efficien- cy, the filters should be replaced at least once a season, or more often under hard water conditions. Use only Emerson HDC-2R or HDC411 replacement filters. NOTE: HDC411 provides two com- Fan Assembly plete filter changes. All filters may be rinsed in
Краткое содержание страницы № 10
Replacement and Care of Filters (continued) 3. a. Remove the two filters and dispose Water Level of properly. Float b. Clean internal parts of the humidifier per the “Cleaning Your Humidifier” Float Retainer section of your owner’s manual. c. Install new filters inside the cabinet with the glue beads on the filter fac- Filters ing the center of the cabinet. Make sure the filters are resting on the floor of the cabinet. d. Return the filter housing to the cabi- net. Position the filter housing on
Краткое содержание страницы № 11
Cleaning Your Humidifier Refer to pages 9 and 10 to remove parts if WARNING: To reduce the risk of injury, fire or damage to humidifier, necessary. use only cleaners specifically rec- NOTE: Before removing the internal parts ommended for humidifiers. Never of the humidifier cabinet, we recommend use flammable, combustible or poi- moving the humidifier to an area where sonous materials to clean your floor coverings are not susceptible to humidifier. To reduce the risk of water damage, i.e., kitc
Краткое содержание страницы № 12
Cleaning Your Humidifier (continued) Bi-Weekly Maintenance End of Season Maintenance Removing Scale 1. Follow “Bi-Weekly Maintenance” 1. Pour one 8 ounce cup of undiluted instructions at end of humidification white vinegar into the cabinet. Let solu- season. tion stay in for 20 minutes. 2. Remove and throw away filters. 2. Clean all interior surfaces with a soft 3. Let humidifier dry completely before brush. Dampen a soft cloth with undi- storing. Do not store with water inside luted white vineg
Краткое содержание страницы № 13
Troubleshooting TROUBLE PROBABLE CAUSE REMEDY Unit will not run • Speed control in off position. • Turn speed control clockwise. and Fill Light is not • Selected humidity level is • Raise humidistat setting if on. obtained. desired. • No power. • Check 120 volt source for power. Unit will not shut • Float is not free. •Free float from obstruction. off. Unit will not dry • This is normal. •A small amount of water remains out completely. in the cabinet after fill light comes on. Bottle continues t
Краткое содержание страницы № 14
Repair Parts PARTS LIST FOR EMERSON HUMIDIFIER MODEL NO. HD7002 1 & HD7005 0 14
Краткое содержание страницы № 15
Repair Parts Key Model Model No. Description HD7002 1 HD7005 0 1Cover, Bottle 825807-1 825807 2 Lid, Stationary 825837-1 825837 3Cover, Dust 825809 825809 4 Knob 826544-1 826544-1 5 Label, Control 826206 826206 6Fan 822406-1 822406-1 8 Motor 828115 828115 9 Screw, Pan Head Type “AB” 10 x 3/4 806742-5 806742-5 10 Support, Motor 828534 828534 11 Housing, Filter 825848 825848 12 Filter, Evaporative HDC-2R HDC-2R or HDC411 or HDC411 13 Rail, Kick 825847-1 825847 15 Caster, Twin Wheel 828515 828515 1
Краткое содержание страницы № 16
FOR TECHNICAL HELP, CALL (800) 654-3545 FROM USA OR (888) 744-4687 FROM CANADA (Please have complete model number) TM 9999 Highway 48 Markham, Ontario Canada L3P 3J3 © 2002 Emerson Electric Co. Part.No. SP6470 Form. No. SP6470 Printed in Canada 06/02