Краткое содержание страницы № 1
Model No. IMSB53950
Serial No.
USER’S MANUAL
The serial number is on a sign
behind the access panel. Write the
serial number in the space above.
Visit our website at Visit our website at
Access
Panel
www.proform.com www.weslo.com
new products, prizes, new products, prizes,
fitness tips, and much more! fitness tips, and much more!
QUESTIONS?
If you have questions, or if there
are missing parts, we will guar-
antee complete satisfaction
Visit our website at Visit our website at
through direct ass
Краткое содержание страницы № 2
Table of Contents Posting the Warning Sign . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Before You Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Краткое содержание страницы № 3
Important Safety Instructions WARNING: To reduce the risk of drowning, electric shock, or serious injury, read the fol- lowing important precautions before using the hydrotherapy spa. READ AND FOLLOW ALL INSTRUCTIONS 1. It is the responsibility of the owner to ensure 10. Never insert any object into any opening. that all users of the hydrotherapy spa are 11. Do not use breakable containers in or near adequately informed of all precautions. the hydrotherapy spa. 2. Use the hydrotherapy spa only a
Краткое содержание страницы № 4
20. DANGER—Risk of electric shock. Keep all physician before using the hydrotherapy spa. electrical appliances such as radios, tele- Pregnant women should not use the spa if phones, televisions, and lights at least five the water temperature is above 100°F; the feet away from the water. unborn child could be seriously harmed. This is especially important during the first 90 21. A wire connector is provided on the electron- days of the pregnancy. ics pack of the hydrotherapy spa to connect a 2 mi
Краткое содержание страницы № 5
35. WARNING: The spa jets produce a stream of water with relatively high pressure. Prolonged exposure of a localized area of the body may cause bruises to the skin. 36. The included warning sign must be posted where all users of the hydrotherapy spa can see and read it. (See POSTING THE WARNING SIGN on page 2.) 37. WARNING DECAL PLACEMENT: Locate the decals shown below and familiarize yourself with the information on the decals. WARNING: Read all instructions before using the hydrotherapy spa. I
Краткое содержание страницы № 6
Before You Begin ® Congratulations for selecting the new IMAGE SYM- For your benefit, read this manual carefully before PHONY hydrotherapy spa. The innovative SYMPHO- using the hydrotherapy spa. If you have questions NY spa allows you to enjoy all the benefits of after reading the manual, please call our Customer hydrotherapy in the comfort and privacy of your home. Service Department toll-free at 1-877-897-7493, Monday through Friday, 8 a.m. until 5 p.m. Central Hydrotherapy is a proven method
Краткое содержание страницы № 7
Choosing a Location for the Hydrotherapy Spa There are many factors to consider when choosing a location to set up the hydrotherapy spa. These factors vary depending on whether you plan to use the spa inside or outside. We have listed several factors you may wish to consider as you decide where to set up the spa. If you set up the hydrotherapy spa inside: If you set up the hydrotherapy spa outside: 1. The spa will increase the level of humidity in your 1. Check local building codes concerning th
Краткое содержание страницы № 8
Wiring the Hydrotherapy Spa This procedure must be performed by a qualified, licensed electrician in accrodance with the nation- Option 1 al electric code, and with all local, state, and feder- al electric code. Under no circumstances should Main Panel the hydrotherapy spa be wired by someone other Spa GFCI Circuit Min. of Breaker than a qualified electrician. 5 feet* Before you have the spa wired, make sure it is in the Suggested Wire Size Wire Length desired position, and that it can be easily
Краткое содержание страницы № 9
Assembly Place all parts of the hydrotherapy spa in a cleared area and remove the packing materials. Do not dispose of the packing materials until assembly is completed. Assembly requires your own phillips screwdriver . 1. Before beginning assembly, make sure that you 1 have read and understand the information above and on the previous two pages. 38 Remove the eight #10 x 2” Machine Screws (37) that secure the indicated Access Panel (25) to the spa. Carefully remove th
Краткое содержание страницы № 10
3. Make sure that a qualified electrician has wired 3 3 the spa to a 240 volt power source. Fill to here Remove the two warning decals (see page 5) from 22 the spa shell. Using a damp cloth, wipe the spa shell clean. Before filling the spa, make sure that it is in the desired position and that there is room to 5 easily service it. Once the spa is filled, it must be drained before it can be moved. Insert a garden hose into the filter housing, and begin filling the spa. Do not use soft water. The
Краткое содержание страницы № 11
Using the Hydrotherapy Spa The hydrotherapy spa is designed to seat seven Once the countdown has reached “000,” “Pr” will adults. The spa holds approximately 375 gallons of be displayed. “Pr” indicates that the controller is in water and offers a heating system (80°F to 104°F), a the two-pump priming mode. This mode will last filtration system, and adjustable hydrotherapy jets. for four to five minutes. Follow the guidelines below to use and maintain the spa for your long-term enjoyment. 5. As
Краткое содержание страницы № 12
8. After one minute, the current temperature of the Once you have tested the GFCI, verify that water is water will be displayed. Push the temperature up flowing from the jets. Set the air controls to the lowest or down button to set the temperature of the setting (see USING THE CONTROLS on page 14). water. If the water temperature is below the set Cover the hydrotherapy spa with the spa cover. The temperature, the heat indicator light will turn on to spa cover must be tight (see SECURING THE SPA
Краткое содержание страницы № 13
Jet Layout Diagram G J M H H H G H J J I I B I J K H N B H B C A E I F B B I L H D H I A. The underwater light can be used for night opera- G. The two neck jets can be adjusted to spray sooth- tion (see USING THE CONTROLS on page 14). ing water on your neck. B. The ten air injectors create air bubbles that H. The twenty-one rotary jets provide a spinning enhance the hydrotherapy experience. massage. C. The volcano jet provides a soothing foot massage. I. The seven dual rotary jets provide a pu
Краткое содержание страницы № 14
Using the Controls Air Controls 1, 2, and 3 Air Control 4 Blower Mode Button Button Display Pump Pump Light Temperature Button 1 Button 2 Button Buttons standard mode is selected. • Economy Mode heats the spa to the set tempera- ture only during the filter cycles. “Ecn” is always dis- 2 played when the actual temperature does not equal 1 1 5 the set temperature. “Ecn” alternates with the actual 2 5 3 3 1 temperature when the actual temperature is the set 5 temperature. 4 5 • Sleep Mode heats t
Краткое содержание страницы № 15
Your spa features an LED light with twelve different The temperature buttons control the temperature set- programmed lighting effects: ting of the water. The temperature setting can be from 1. Lights cycle between Red, Green, and Blue 80°F to 104°F. The startup temperature is set at 2. Dark Blue 100°F. The water heats at about 6°F per hour with the 3. Orange cover on. Use a medical or other accurate thermome- 4. Purple ter to check the temperature of the water. 5. Green 6. Red To change the w
Краткое содержание страницы № 16
Maintenance The hydrotherapy spa is designed to provide years of MAINTAINING THE SPA COVER enjoyment. Please follow the guidelines below to properly maintain your spa. The spa cover should be cleaned monthly. To clean the spa cover, use water and a non-abrasive cleaner MAINTENANCE SCHEDULE on the entire cover. Rinse the cover with a garden hose to remove any cleaner residue. Dry the cover Daily entirely. Use a non-silicone-based vinyl conditioner on • Check the water level and refill the spa to
Краткое содержание страницы № 17
WATER CHEMISTRY To maintain the proper pH level, test the pH of the water regularly. To test the water, purchase a pH test Maintaining the pH level of the water is very important kit at a pool and spa supply store. The pH reading to the operation of the spa. To maintain the proper pH should be between 7.2 and 7.8. If the level is too low, level and to sanitize the spa, you can purchase a add a pH increaser (usually soda ash). If the level is chemical starter kit from your local pool and spa sup-
Краткое содержание страницы № 18
ATTACHING AND REMOVING THE ACCESS PANEL To drain the hydrotherapy spa, follow the steps below: Turn off the spa power. Remove the eight #10 x 2” 1. Using the console, adjust the temperature to the Machine Screws (37) that secure the indicated Access lowest setting. Panel (25) to the spa. Carefully remove the Access 2. Shut off the power to the spa, at the circuit break- Panel until the CD wire harness (not shown) is visible er or GFCI. and disconnect it. Set the Access Panel aside. Be 3. Remove
Краткое содержание страницы № 19
DRAINING THE PUMPS REPLACING THE LED LIGHT After the hydrotherapy spa is drained, the jet pumps Remove the access panels (see ATTACHING AND should also be drained if the spa will be stored for REMOVING THE ACCESS PANELS on page 18). more than thirty days or if it may be exposed to freez- Make sure the spa power is turned off. Next, locate the ing temperatures. light housing. Turn the light housing counterclockwise and remove it from the spa shell. Turn off the power to the spa. To drain the jet
Краткое содержание страницы № 20
Troubleshooting Most problems can be solved by following the simple steps below. Find the symptom that applies, and follow the steps listed. If further assistance is needed, call our Customer Service Department toll-free at 1-877-897-7493, Monday through Friday, 8 a.m. until 5 p.m. Central Time. 1. SYMPTOM: THE SPA WILL NOT OPERATE 6. SYMPTOM: THE WATER DOES NOT HEAT a. Check to see if the GFCI breaker is tripped or a. Make sure that the hydrotherapy spa is fully was not turned on. Reset the G