Краткое содержание страницы № 1
OWNERS MANUAL
MODEL SERIES: P1204
Stationary Standby Electric Generator
IMPORTANT SAFETY INSTRUCTIONS – Please make certain that persons who are to install, operate and
maintain this equipment thoroughly read and understand these instructions prior to operation. SAVE THESE
INSTRUCTIONS — This manual contains important instructions that should be followed during installation
and maintenance of the generator and battery.
Product style and configuration may vary.
Specifications are subject to cha
Краткое содержание страницы № 2
T TA AB BL LE E O OF F C CO ON NT TE EN NT TS S T TA AB BL LE E O OF F C CO ON NT TE EN NT TS S Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 General Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Краткое содержание страницы № 3
G GE EN NE ER RA AL L S SA AF FE ET TY Y G GU UIID DE EL LIIN NE ES S G GE EN NE ER RA AL L S SA AF FE ET TY Y G GU UIID DE EL LIIN NE ES S The following information relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS. To help you recognize this information, we use the following symbols. Please read the manual and pay attention to these sections. Also read and follow all safety labels on the engine/generator set. If labels are damaged or unreadable, contact product service for re
Краткое содержание страницы № 4
G GE EN NE ER RA AL L S SA AF FE ET TY Y G GU UIID DE EL LIIN NE ES S ( (C Co on nt tiin nu ue ed d) ) G GE EN NE ER RA AL L S SA AF FE ET TY Y G GU UIID DE EL LIIN NE ES S ( (C Co on nt tiin nu ue ed d) ) WARNING: CAUTION: Units with broken or missing parts, without The National Electrical Code (NEC) requires the protective housing or covers should never be frame and external electrically conductive parts of operated. Contact your service center for the generator to be connected to an appr
Краткое содержание страницы № 5
After inspecting the generator, engine and enclosure IIN NT TR RO OD DU UC CT TIIO ON N IIN NT TR RO OD DU UC CT TIIO ON N for physical damage, finish reading the Operating and The stationary standby electric generator is Maintenance Instructions. These manuals contain manufactured for our customers to supply reliable important safety information. backup power. The generator is a compact unit, W WA AR RN NIIN NG G designed to supply the power for your critical needs RISK OF INJURY AND BEING
Краткое содержание страницы № 6
G GE EN NE ER RA AT TO OR R S SP PE EC CIIF FIIC CA AT TIIO ON NS S G GE EN NE ER RA AT TO OR R S SP PE EC CIIF FIIC CA AT TIIO ON NS S P120401 (12 KW) Rated Wattage - (Standby) @1.0 PF LPG * 12,000 Rated Wattage - (Standby) @1.0 PF NG * 9,800 Voltage 120/240 volts Rated Current 100/50 amps LPG Frequency 60 HZ Power Factor 1.0 Max. Ambient Temp Rise 105°C Insulation class H Engine Subaru EH72 Engine Type Air cooled V-twin (2 cylinders) RPM 3600 Displacement cc (c.i.d) 43.9 cu. in. (720 cm³) Bore
Краткое содержание страницы № 7
IIN NS ST TA AL LL LA AT TIIO ON N D DR RA AW WIIN NG GS S IIN NS ST TA AL LL LA AT TIIO ON N D DR RA AW WIIN NG GS S 200-2653 7
Краткое содержание страницы № 8
Power leads from the generator/circuit G GE EN NE ER RA AT TO OR R IIN NS ST TA AL LL LA AT TIIO ON N G GE EN NE ER RA AT TO OR R IIN NS ST TA AL LL LA AT TIIO ON N breaker being wired to the transfer switch Once installation planning is complete and all should be tightened in the identified terminal necessary local permits are granted, installation of the block to 120 lb-in. The wire size is to be generator may begin. Within the following section selected according to allowable ampacities
Краткое содержание страницы № 9
P PL LA AC CE EM ME EN NT T A AN ND D A AN NC CH HO OR RIIN NG G P PL LA AC CE EM ME EN NT T A AN ND D A AN NC CH HO OR RIIN NG G The generator is supplied with an integral molded plastic base for use as an installation pad. Use of this base is intended to minimize installation cost by eliminating the need for a poured concrete pad. A pad of crushed gravel a minimum of three inches thick is recommended as a base to set the generator on. Compact the gravel and ensure that the pad is level in all
Краткое содержание страницы № 10
complex nature of electrical distribution systems, the A AU UT TO OM MA AT TIIC C T TR RA AN NS SF FE ER R S SW WIIT TC CH H A AU UT TO OM MA AT TIIC C T TR RA AN NS SF FE ER R S SW WIIT TC CH H sizing, selection and installation of a switch is best handled by a licensed electrician or qualified standby When connecting the generator to a building generator dealer. Any switch installation must be electrical distribution system, use of a transfer switch is performed by a licensed electrician to th
Краткое содержание страницы № 11
E EL LE EC CT TR RIIC CA AL L H HO OO OK KU UP P M MA AIIN N L LIIN NE E O OU UT TP PU UT T P PO OW WE ER R E EL LE EC CT TR RIIC CA AL L H HO OO OK KU UP P M MA AIIN N L LIIN NE E O OU UT TP PU UT T P PO OW WE ER R Once the generator is anchored in its final position, it The output circuit of the generator is 4-wire, 240V, is ready for electrical connections. The generator is rated for the amperage as shown on the generator supplied with two terminal blocks for connection of three nameplate.
Краткое содержание страницы № 12
U U U UT T T TIIIIL L L LIIIIT T T TY Y Y Y C C C CIIIIR R R RC C C CU U U UIIIIT T T T S S S SU U U UP P P PP P P PL L L LY Y Y Y G G G GE E E EN N N NE E E ER R R RA A A AT T T TO O O OR R R R S S S ST T T TA A A AR R R RT T T T S S S SIIIIG G G GN N N NA A A AL L L L A receptacle is provided with the generator to power When the control panel mode switch is placed in the the battery charger for reliable starting. It is also AUTO position, generator starting and stopping is intended to powe
Краткое содержание страницы № 13
WIRING DIAGRAM WIRING DIAGRAM 200-2667 13
Краткое содержание страницы № 14
F FU UE EL L S SP PE EC CIIF FIIC CA AT TIIO ON NS S A AN ND D W WA AR RN NIIN NG G F FU UE EL L S SP PE EC CIIF FIIC CA AT TIIO ON NS S A AN ND D C C C CO O O ON N N NS S S SU U U UM M M MP P P PT T T TIIIIO O O ON N N N R R R RE E E EQ Q Q QU U U UIIIIR R R RE E E EM M M ME E E EN N N NT T T TS S S S The engine driving the generator is engineered to • Natural gas (NG) is highly explosive. provide reliable power on either Liquefied Propane Vapor • Natural gas (NG) is lighter than air and will
Краткое содержание страницы № 15
Natural Gas (NG) Units are tested with natural gas before they leave the factory. If natural gas is to be used, no adjustments are required. When supplying natural gas as the operating fuel, 3 provide fuel with a minimum of 1000 BTU/ft at inlet pressures between 6" and 11" of water column (4 - 6 oz). Failure to meet these minimums will cause the generator to run poorly and/or may limit output to values below nameplate value. If fuel with these qualities is not available, contact the customer
Краткое содержание страницы № 16
B BA AT TT TE ER RY Y R RE EQ QU UIIR RE EM ME EN NT TS S B BA AT TT TE ER RY Y R RE EQ QU UIIR RE EM ME EN NT TS S C CA AU UTTIIO ON N To insure reliable starting in most weather conditions, it is important to properly match a battery to the requirements of the generator. The generator uses a A battery presents a risk of electrical shock and a 12 Volt, direct current, negative ground control system high short circuit current. The following precautions powered by an automotive style lead acid ba
Краткое содержание страницы № 17
The final step of battery installation is to verify proper B B B BA A A AT T T TT T T TE E E ER R R RY Y Y Y P P P PL L L LA A A AC C C CE E E EM M M ME E E EN N N NT T T T A A A AN N N ND D D D connection of all battery charger connections. A battery C CO ON NN NE EC CT TIIO ON N ( (c co on nt t..) ) C CO ON NN NE EC CT TIIO ON N ( (c co on nt t..) ) charging system (G) is included with the To access the battery and charger, remove the front engine/generator set to maintain the battery charge
Краткое содержание страницы № 18
valves in the fuel supply system. F F F FIIIIR R R RS S S ST T T T T T T TIIIIM M M ME E E E S S S ST T T TA A A AR R R RT T T TU U U UP P P P 6. Press the MANUAL button on the control panel. The After completing all installation procedures, read and generator should crank and start. understand the operating instructions for the generator 7. Allow the generator to run for approximately three (3) controller. Know how the control panel operates, what to minutes, then move the main line circui
Краткое содержание страницы № 19
the Emergency position. C CO ON NT TR RO OL L P PA AN NE EL L F FE EA AT TU UR RE ES S C CO ON NT TR RO OL L P PA AN NE EL L F FE EA AT TU UR RE ES S F. Generator Power Monitor LED A. MODE BUTTONS (AUTO, MANUAL AND OFF) The generator power monitor LED will illuminate Red B. AUTO LED when the Voltage Sensing detects that the Generator C. STATUS INDICATOR LED’s source is available. D. UTILITY POWER MONITOR LED G. Generator Hour Meter E. TRANSFER SWITCH MONITOR LED The Generator Hour Meter is provi
Краткое содержание страницы № 20
intended for generator control during maintenance or if G GE EN NE ER RA AT TO OR R C CO ON NT TR RO OL L P PA AN NE EL L G GE EN NE ER RA AT TO OR R C CO ON NT TR RO OL L P PA AN NE EL L an automatic transfer switch is not used. With the control O O O OP P P PE E E ER R R RA A A AT T T TIIIIO O O ON N N N panel switch shifted to this position, the generator will RUN MODES immediately attempt to start after a brief pause. Upon starting, the generator runs until the switch is moved There are thre