Краткое содержание страницы № 1
®
Unvented (Vent-Free) LogMate Stove
This stove may be installed in an aftermarket* manufactured (mobile) home, where not
prohibited by state or local codes.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
(i.e. Installation of this product is permitted after the manufactured (mobile) home is sited).
OWNER’S
SVFBC
OPERATION
Краткое содержание страницы № 2
SECTION PAGE CONTENTS Safety Information ................................................................................................. 2 Product Specifications ........................................................................................... 4 Local Codes ........................................................................................................... 5 Unpacking..............................................................................................................
Краткое содержание страницы № 3
WARNINGS Continued WARNING ICON G 001 WARNING: Any change to this heater or its controls can be dangerous. SAFETY 1. This stove shall not be installed in a bedroom or bathroom. INFORMATION 2. Never install the stove Continued • in a recreational vehicle • where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the stove • in high traffic areas • in windy or drafty areas 3. Do not use this stove as a wood-burning fireplace. Use onl
Краткое содержание страницы № 4
28" PRODUCT 1" SPECIFICATIONS 22 3/4" 19" 20 1/4" 31 1/2" 27" Door 16 5/8" Handle 7 3/4" 24" 1" 18 1/2" 26 1/2" Figure 1 - Stove Front View 19 1/2" 4" 15 1/2" 1 1/2" 1" 13 1/2" 4" 1" 1" 16" 12" 14 1/2" 18 1/2" Figure 2 - Stove Side View 4 103661
Краткое содержание страницы № 5
28" PRODUCT SPECIFICATIONS Continued 15 1/2" 4" Figure 3 - Stove Top View Install and use stove with care. Follow all local codes. In the absence of local codes, LOCAL CODES use the latest edition of The National Fuel Gas Code ANSI Z223.1, also known as NFPA 54*. *Available from: American National Standards Institute, Inc. 1430 Broadway New York, NY 10018 National Fire Protection Association, Inc. Batterymarch Park Quincy, MA 02269 UNPACKING NOTICE Keep stove upright when removing from carton
Краткое содержание страницы № 6
Operation PRODUCT This stove is designed to accept all gas log heaters listed in Table 1, page 2. It requires no outside venting or chimney making installation easy and inexpensive. When used FEATURES without the blower, the stove requires no electricity making it ideal for emergency back- up heat. Blower Accessory The stove will accept the GA3700 accessory. The variable blower allows you to select the fan speed you desire. The blower circulates heated air from the stove into the room. Use of bl
Краткое содержание страницы № 7
PROVIDING ADEQUATE VENTILATION AIR FOR The following is exerpts from National Fuel Gas Code. NFPA 54/ANSI Z223.1, Section 5.3, Air for Combustion and Ventilation. COMBUSTION All spaces in homes fall into one of the three following ventilation classifications: AND 1. Unusually Tight Contruction; 2. Unconfined Space; 3. Confined Space. The information on pages 6 through 9 will help you classify your space and provide VENTILATION adequate ventilation. Continued Unusually Tight Construction The air
Краткое содержание страницы № 8
DETERMINING AIR FLOW FOR STOVE LOCATION AIR FOR Determining if You Have a Confined or Unconfined Space COMBUSTION Use this work sheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install stove plus any adjoining rooms with AND doorless passageways or ventilation grills between the rooms. VENTILATION 1. Determine the volume of the space (length x width x height). Continued Length x Width x Height = ___________________ cu. ft. (volume of space
Краткое содержание страницы № 9
VENTILATION AIR AIR FOR Ventilation Air From Inside Building COMBUSTION This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of AND the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 4). You can also remove door into adjoining room (see option 3, VENTILATION Figure 4). Follow the National Fuel Gas Code NFPA 54/ANSI Z223.1,
Краткое содержание страницы № 10
INSTALLING NOTICE A qualified service person must install stove. Follow all local codes. WARNING WARNING ICON G 001 Never install the stove • in a bedroom or bathroom • in a recreational vehicle • where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the stove • in high traffic areas • in windy or drafty areas CAUTION WARNING ICON G 001 Log heaters installed in this stove create warm air currents. These currents move heat to wa
Краткое содержание страницы № 11
B. Clearances from the side of the stove opening to any combustible wall should not be INSTALLING less than 20 inches (see Figure 7). C. Clearances from the top of the stove opening to the ceiling should not be less Continued than 52 inches (seeFigure 7). 52" 20" 20" Door Handle Figure 7 - Minimum Clearance to Wall and Ceiling INSTALLING GA3700 BLOWER ACCESSORY 1. Install blower assembly per instruction sheet included in blower accessory kit. 2. Route blower power cord out the back of the stove
Краткое содержание страницы № 12
You may have further questions about installation, operation, or troubleshooting. TECHNICAL If so, contact DESA International’s Technical Service Department at 1-800-323-5190. SERVICE Note: Use only original replacement parts. This will protect your warranty coverage REPLACEMENT for parts replaced under warranty. PARTS Parts Under Warranty Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International’s Technical Service Department at 1-800
Краткое содержание страницы № 13
This list contains replaceable parts used in your stove. When ordering parts, follow ILLUSTRATED the instructions listed under Replacement Parts on page 12 of this manual. PARTS BREAKDOWN Model SVFBC KEY NO. PART NUMBER DESCRIPTION QTY. 1 103657-01 Door (includes 5 screws) and Handle 1 2 103693-01 Button Plug 1 3 103659-01 Brass Trim Kit (upper and lower) (includes 6 screws) 2 4 103660-01 Door Latch Kit (includes 2 screws) 1 PARTS AVAILABLE — NOT SHOWN 103662-01 Touch Up Paint 1 3 1
Краткое содержание страницы № 14
NOTES __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ _________________________
Краткое содержание страницы № 15
NOTES __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ _________________________
Краткое содержание страницы № 16
WARRANTY INFORMATION KEEP THIS WARRANTY Model Serial No. Date Purchased Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied. LIMITED WARRANTY VENT-FREE STOVE DESA International warrants this product to be free from defects in materials and components for three (3) years from the date