Краткое содержание страницы № 1
EF5001B-AL Pellet Heater
Installation & Operating Instructions
Please read this entire manual before installation. Save these instructions.
GENERAL INFORMATION
Installation and repair should be done by a qualified service
person. The heater should be inspected before use and at
least annually by a professional service person. More
frequent cleaning may be required due to fuel quality,
excessive lint from carpeting, bedding material, etc. It is
imperative that control compartments, burners and ci
Краткое содержание страницы № 2
Figure 2 WARNING: Installation of a Mobile Home Attachment Kit Figure 1 -Overall Dimensions P/N 10412 and outside combustion air is mandatory in mobile or modular home installations although it may also be used in all residential applications. OUTSIDE COMBUSTION AIR IS MANDATORY IN An outside air inlet MUST be provided for combustion MOBILE OR MODULAR HOME INSTALLATIONS. and ventilation air. The air inlet must remain unrestricted while unit is in use. Outside air connection is located in the C
Краткое содержание страницы № 3
Figure 3 c. 2 ft. minimum to an adjacent building and 7 ft. minimum above grade when located adjacent to public walkways. Figure 5 Figure 4 Figure 6 3
Краткое содержание страницы № 4
IMPORTANT - Any electrical work performed on the UNIT INSTALLATION EASYFIRE Heater should be done by qualified personnel. Route the power supply cord so that it does not touch any of the exterior components of the heater. 1. W hen exiting through the wall with your type L Pellet vent pipe, you may go straight out through a wall thimble. You must connect a pellet vent tee at this point and extend the vent pipe at least 3' (three feet) vertically outside to provide good draft and allow the gase
Краткое содержание страницы № 5
stove operates based on the EasyFire digital control system requirements. If the house AC power should quit, the AutoLite system will not be available however, with the optional battery attached the stove can be manually lit and operate on battery power for several days (depending on battery size). START-UP AND OPERATION Warning: This stove incorporates a hopper lid safety switch. The feed system will remain in-operable when the door is open. Figure 9 Door handle assembly Priming the feed syst
Краткое содержание страницы № 6
B. In the LOW position, the EASYFIRE will be feeding Feed Trim Adjustment approximately 1 to 1½ lbs. of pellets per hour and the flame will fluctuate between 1" and 6" in height. Underneath the control button you will find a small round button that will turn forward and reverse. This button can C. In the MEDIUM position the EASYFIRE will be feeding adjust the feed motor in the LOW operating position. By approximately three (3) pounds of pellets per hour and turning the button clockwise you can
Краткое содержание страницы № 7
heat exchanger hot before turning it to "LOW ". You will are disposed of by burial in soil or otherwise locally need to burn the heater for a few hours before deciding dispersed, they should be retained in the closed container which setting is best for your particular needs. until all cinders have been thoroughly cooled. NOTE: CAUTION MUST BE TAKEN WHEN OPTIONAL 12V HOOK-UP & OPERATION INSTALLING BURN POT OR OPERATING DOOR NOT TO DAMAGE CERAMIC GLASS. DO NOT ATTEMPT TO 1. The EASYFIRE 12V back
Краткое содержание страницы № 8
4. Clearance to combustibles may only be reduced by a. Open door and remove clean out slide cover. To means approved by the regulatory authority. remove, simply slide up and out from retaining angle bracket (Figure 10). Clean one side at a time. With one slide cover removed, leave door open and turn 5. Store pellet fuels in a dry area away from unit. Do not control knob to the "CLEAN" position. Let heater run store fuels within the space heater installation until ash in fire pot area is vacuumed
Краткое содержание страницы № 9
existing flue must be installed with a tee connector frame. Apply sealer to mating edge of glass and frame. Allow two hours dry time before installing door onto (Figure 3,4,& 5) to allow access to clean the ash from the pellet vent pipe. heater. Note: Replace with Pyro-Ceramic Glass only. Refer to parts list for specifications. TROUBLE-SHOOTING The following scenarios are provided in order to help you locate a difficulty if the heater performs in a manner which would seem to indicate a malfunct
Краткое содержание страницы № 10
6. Problem: After several weeks of outstanding perfor- mance, the heater suddenly stopped and the red light under the control knob came on. This light is the Hi Temp/Flue Indicator Light. Solution: The Hi-Temp/Flue Indicator light indicates 10. Problem: Feed system jammed. that fly ash has built up in the exhaust system and/or there is a restriction in the exhaust/flue system. Check the pipe system for excessive ash and clogging, Solution: This condition is caused by fuel contaminated particul
Краткое содержание страницы № 11
` ITEM No. PART NUMBER DESCRIPTION 1 110541 HOPPER LID SAFETY SWITCH 2 110499 DOOR GLASS (CERAMIC 11"x11 3/4"x5mm) 3 100125 DOOR GASKET, WOVEN FIBER 4 110451 ASH DUMP KNOB 5 300522 ASH DRAWER 6 202105 HEAT EXCHANGE COVER 7 300502 FIREPOT - AL V2 8 120117 AUTOLITE IGNITER 9 202164 BURN POT SCREEN - AL 10 120120 AUTOLITE POWER RELAY 11 120118 AUTOLITE PUSH BUTTON SWITCH 12 120114 MAIN CONTROL BOARD V2.2 -A L 13 10475 COMBUSTION/CONVECTION FAN ASSY. 14 110070 CONVECTION