Краткое содержание страницы № 1
C
N
E
R
G
T
I
Direct Vent Gas Fireplace
Models: DV360, DV580
INSTALLER / CONSUMER
SAFETY INFORMATION
PLEASE READ THIS MANUAL
BEFORE INSTALLING AND USING
APPLIANCE
WARNING!
IF THE INFORMATION IN THIS
MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR
EXPLOSION MAY RESULT
CAUSING PROPERTY DAMAGE,
PERSONAL INJURY OR LOSS OF
LIFE.
FOR OUR SAFETY
Homeowner’s Installation and
Installation and service must be
performed by a qualified installer, Operating Manual
6357
service agency or the gas supplier
Краткое содержание страницы № 2
DV360/580 Series Direct Vent Gas Fireplace Installation & Operating Instructions This gas appliance should be installed by a qualified installer in WARNING: Check with your electronics manufac- accordance with local building codes and with current CSA- turer before installing a television or other electronic B149.1 Installation codes for Gas Burning Appliances and Equipment. If the unit is being installed in a mobile home, the device above this fireplace. installation should comply with the c
Краткое содержание страницы № 3
DV360/580 Series Direct Vent Gas Fireplace Fireplace Dimensions (Installed as Top Vent) Rough J Opening P Depth V I T Q H K Recessed Nailing Flange K S - Rough Opening Width W V Rough U Opening G Height F R B D C Electrical Gas Line Access Access E L A N M O G Fig. 2 Fireplace specifications and framing dimensions. 2261b Ref. DV360 DV580 DV360 A 41” (1041 mm) Specs - top vent 47” (1194 mm) 1/25/00 djt B 37” (940 mm) 41 ¹⁄₄” (1048 mm) C 36” (914 mm) 42” (1067 mm) D 24 ¹⁄₂” (622 mm)
Краткое содержание страницы № 4
DV360/580 Series Direct Vent Gas Fireplace Fireplace Dimensions (Installed as Rear Vent) Rough I Opening Depth U S H J Recessed Nailing Flange J R - Rough Opening Width U V Rough Opening T G Height F P Q B D C Electrical O Gas Line Access Access E K A M L N G Fig. 3 Fireplace specifications and framing dimensions. 2261a Ref. DV360 DV580 DV360 A 41” (1041 mm) 47” (1194 mm) Specs rear vent 1/25/00 djt B 37” (940 mm) 41 ¹⁄₄” (1048 mm) C 36” (914 mm) 42” (1067 mm) D 24 ¹⁄₂” (622 mm)
Краткое содержание страницы № 5
DV360/580 Series Direct Vent Gas Fireplace Clearance to Combustibles Top of unit to ceiling ................................. 36” (914 mm) Front of unit to combustibles ................... 36” (914 mm) Appliance Top of standoff ....................................... 0” (0 mm) Bottom ..................................................... 0” (0 mm) Side ......................................................... 0” (0 mm) J I Back ........................................................ 0” (0 m
Краткое содержание страницы № 6
DV360/580 Series Direct Vent Gas Fireplace C Framing And Finishing Adjustable Drywall Strip (Nailing Flange) A Check fireplace to make sure it is levelled and properly positioned. B Flange Drywall To mount the appliance: Choose the location. Position Depth A 1/2” / 13 mm DV360 (Fig. 5) B 5/8” / 16 mm 1. This unit comes with four (4) flanges pre-mounted C 3/4” / 19 mm on both sides of the fireplace to allow two different drywall thicknesses to be used. Flange “A” is for 1/2” drywall while
Краткое содержание страницы № 7
TP TPTH TH DV360/580 Series Direct Vent Gas Fireplace The gas control is equipped with a captured screw type High Elevations pressure test point, therefore it is not necessary to pro- Input ratings are shown in BTU per hour and are vide a 1/8” test point up stream of the control. certified without deration for elevations up to When using copper or flex connector use only approved 4,500 feet (1,370m) above sea level. fittings. Always provide a union when using black iron For elevations above 4,
Краткое содержание страницы № 8
LO FRONT OF UNIT DV360/580 Series Direct Vent Gas Fireplace EB-1 Electrical Box Electronic Gas Control Valve The fireplace, when installed, must be This appliance may be fitted with a Honeywell igni- electrically connected and grounded in tion module. accordance with local codes or, in the ab- Installation of the remote on/off switch on electron- sence of local codes, with the current CSA ic ignition units. C22.1 Canadian Electrical Code. 1. Thread the wiring through the holes on the side Fo
Краткое содержание страницы № 9
DV360/580 Series Direct Vent Gas Fireplace CAUTION: Remove insulation. Insulation extends Optional Top Vent Application beyond opening in top of unit. Be sure to The DV360/580 fireplace is shipped as a rear vent unit. remove all insulation before completing If the layout requires a top vent, convert the unit follow- conversion. Insulation measures 9 ¹⁄₄” x ing the steps below. 22 ³⁄₄” (23.5 cm x 57.8 cm). If the unit is con- verted back to a rear vent, the insulation 1. Remove the 10 screws
Краткое содержание страницы № 10
DV360/580 Series Direct Vent Gas Fireplace General Venting There must not be any obstruction such as bushes, gar- Your fireplace is approved to be vented either through den sheds, fences, decks or utility buildings within 24” the side wall, or vertical through the roof. (610 mm) from the front of the termination hood. • Only CFM Corporation venting components spe- Do not locate termination hood where excessive snow cifically approved and labelled for this fireplace or ice build up may occur. Be
Краткое содержание страницы № 11
V V Operabl e DV360/580 Series Direct Vent Gas Fireplace General Venting Information - Termination Location INSIDE CORNER DETAIL G V N H N A D E B C B Fixed Fixed L V B V Closed Closed V Fixed Operable G Closed F V V B M V G B J X B I V K X V A A VENT TERMINATION AIR SUPPLY INLET AREA WHERE TERMINAL IS NOT PERMITTED V X CFM145a 1 2 Canadian Installations US Installations CFM145a A = Clearance above grade, veranda, porch, 12” (30cm) 12” (30cm) DV Termin Location 5/01/01 Rev. 12/05/01
Краткое содержание страницы № 12
DV360/580 Series Direct Vent Gas Fireplace Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. Inside Corner Recessed Location Outside Corner D B = C C Combustible A = 6"(152mm) Combustible E A 6"(152mm) Noncombustible V V 2"(50mm) Noncombustible 2"(50mm) V B Balcony - Balcony - with no side wall with perpendicular side wall C = Maximum depth of 48" (1219mm) for recessed H G location. V V D = Minimum width
Краткое содержание страницы № 13
DV360/580 Series Direct Vent Gas Fireplace Twist Lock Pipes 30 When using twist lock pipe it is not necessary to use 29 sealant on the joints. The only areas of the venting 28 system that need to be sealed with high temperature 27 silicone sealant are the sliding joints of any telescopic 26 vent section used in the system. 25 24 To join twist lock pipes together, simply align the beads 23 of the male end with the grooves of the female end, 22 twisting the pipe until the flange on the femal
Краткое содержание страницы № 14
DV360/580 Series Direct Vent Gas Fireplace Vent Opening for Combustible Walls 9 ³⁄₈” (240 mm) Rear Vent Top View 20” (508 mm) Max. 10 ³⁄₈” (265 mm) DVR584-600 Framing Detail Fireplace Hearth Fig. 20 Rear vent application, no elbows. 20” Opening for Noncombustible Wall 20” DVR584-600 (508 mm) (508 mm) Max. Max. Rear vent no elbows 2/99 djt 7 ¹⁄₂” 45° 45° (190 mm) Fireplace Hearth VO584-100 Fig. 22 Locate vent opening on wall. Max. Length Adjustable Zero 12” (305 mm) Clearance Sleeve VO584
Краткое содержание страницы № 15
DV360/580 Series Direct Vent Gas Fireplace Finished Wall Rise Vent Termination FP1472 Fig. 26 There must be a 1/2” rise per foot length. Vertical Sidewall Application Since it is very important that the venting system maintain its balance between the combustion air intake and the flue gas exhaust, certain limitations FP1472 as to vent configurations apply and must be strictly rise in length adhered to. FP1005 4/04 djt The Vent Graph, showing the relationship between ver- Fig. 24 Side view
Краткое содержание страницы № 16
DV360/580 Series Direct Vent Gas Fireplace Vertical Sidewall Installation Max. Length Adjustable Zero 12” (305 mm) Twist Lock Pipe Clearance Sleeve Step 1 #8 Screws (2) Locate vent opening on the wall. It may be necessary to first position the fireplace and measure to obtain hole #8 Screws (2) location. Depending on whether the wall is combustible #8 Screws or noncombustible, cut opening to size. (Fig. 32) (For (2) combustible walls first frame in opening.) NOTE: When using flex vent, the op
Краткое содержание страницы № 17
DV360/580 Series Direct Vent Gas Fireplace 7’ 3 x 90° 3 x 90° (2.1 m) Elbows Elbows A 10’ (3 m) B FP1176 8’ Fig. 27 Maximum three (3) 90° elbows per installation. (2.4 m) 36" (914mm) Max. 36" V584-201 (914mm) Max. Fig. 30 Maximum vent run with elbows. In Figures 29 & 30, dimension A plus B must not be V584-201 greater than 17’ (5.2m) Horizontal Run 2/99 djt • The maximum number of 45° elbows permitted per side wall installation is two (2). These elbows can be FP1177 installed in ei
Краткое содержание страницы № 18
DV360/580 Series Direct Vent Gas Fireplace X 4” Flex Vent Pipe 12" (305mm) X Spacer Spring 6" (152mm) 5" (127mm) 6 ³ ⁄ ₄" (172mm) FP1474 FP1182 Fig. 36 Install spacer springs. Fig. 35 Horizontal length requirement. Step 4 Step 7 Install the 4” (102 mm) flex vent pipe to the appliance FP1474 Apply high temperature sealant to 4” (102 mm) and collar as described on Page 13. Secure the end with the spacer springs 7” (178 mm) collars or the termination one inch away first spring 6 ³⁄₄” (172 mm) f
Краткое содержание страницы № 19
DV360/580 Series Direct Vent Gas Fireplace Do not back fill around snorkel. Below Grade Installation A clearance of at least 4” must be main- When it is not possible to meet the required vent ter- tained between the snorkel and the soil. minal clearances of 12” (305 mm) above grade level, a If the foundation is recessed, use recess brackets (not snorkel kit is recommended. It allows installation depth supplied) for securing lower portion of the snorkel. Fas- down to 7” (178 mm) below grade lev
Краткое содержание страницы № 20
DV360/580 Series Direct Vent Gas Fireplace Vertical Through-the-Roof Installation Max. Height 40’ (12.2 m) 1. Locate your fireplace. Min. Height 8’ (2.4 m) 2. Plumb to center of the (4”) flue collar from ceiling above and mark position. 3. Cut opening equal to 9 ³⁄₈” x 9 ³⁄₈” (240 mm x 240 mm). Max. 10’ (3 m) 4. Proceed to plumb for additional openings through the roof. In all cases, the opening must provide a minimum of 1 inch clearance to the vent pipe, i.e., the hole must be at least 9 ³⁄₈”