Краткое содержание страницы № 1
care and operation
instructions
DIRECT VENT
®
ELITE SERIES
WARNINGS
Vented Gas FirepLace Heaters - direct Vent ModeLs
• Hot! Do not touch! The glass and p/n 875,030M reV. B 05/2008
surfaces of this appliance will be hot
during operation and will retain heat MODELS
for a while after shutting off the appli-
ance. Severe burns may result. Millivolt Models Electronic Models
• Carefully supervise children in the
ELDV-35NM ELDV-35NE
same room as appliance.
ELDV-35PM ELDV-40NE
• If small childr
Краткое содержание страницы № 2
GeneraL inForMation conGratuLations! Note: Installation and repair should be per- In selecting this LENNOX Direct-Vent Gas Appliance you have chosen the finest and most formed by a qualified service person. The dependable fireplace to be found anywhere. It is a beautiful, prestigious, alternative to a appliance should be inspected annually by a wood burning fireplace. Welcome to a Family of tens of thousands of satisfied LENNOX Fireplace Owners. qualified professional service technician.
Краткое содержание страницы № 3
Table 1 shows the units' gas orifice size for Any safety guard or screen removed for ser- aVertis s eMent: sur VeiLLer Les the elevations indicated. vicing the appliance must be replaced prior to enFants. Garder Les VêteMents, operating the appliance. Les MeuBLes, L'essence ou autres Elevation Orifice size Model Feet LiQuides à Vapeur inFLaMMaBLes WarninG: FaiLure to coMpLY WitH No. (meters) Nat. Prop. Loin de L'appareiL. tHe instaLLation and operatinG instructions pro Vided in t His E
Краткое содержание страницы № 4
O W VENT TH TH TP TP T H N Gas controls/control compartment access Pilot Stage Pressure-Tap Pilot Gas (Inlet) Terminal Outlet The gas controls can be found behind the bottom panel. Remove the bottom panel by pulling it towards the front. Ground (TP) On millivolt systems, the piezo ignitor, Hi/Lo flame adjustment knob, and pilot and main HI LO Supply Gas gas ON/OFF control knob are located behind Gas Outlet Inlet To Burner the panel. See Figure 1. Operation of millivolt and electronic gas
Краткое содержание страницы № 5
Maintenance schedule annually (Before the onset of the Burning Season) Maintenance t ask accomplishing person procedure Inspecting/Cleaning Burner, Logs Qualified Service Technician Inspect valve and ensure it is properly op- and Controls erating. Check piping for leaks. Vacuum the control compartment, fireplace logs and burner area. Check Flame Patterns and Flame Height Qualified Service Technician Refer to Figures 6 (ELDV35), 7 (ELDV40) or 8 (ELDV45) on page 7 and verify the flame patte
Краткое содержание страницы № 6
Refer to the maintenance schedule for mainte- 2. Locate the two (2) latches at the top of the Sooting is indicated by black puffs developing nance tasks, procedures, periodicity and by whom control compartment and disengage them from at the tips of very long orange flames. Sooting they should be performed. Always verify proper the floor frame bottom Vee-flange, pulling down results in black deposits forming on the logs, operation of the appliance after servicing. on their handles to open the
Краткое содержание страницы № 7
Carefully position the ceramic fiber logs and twigs over the burner as shown in Figures 6 (ELDV35), Air 7 (ELDV40) or 8 (ELDV45) on this page. Shutter Rod These fires are designed to provide a rich orange/red glow on the logs. Placement of the rear log Venturi is critical and can be adjusted to taste. refer to the detailed log placement instructions provided in the LoG pLaceMent Guide accompanying this document. Valve Lever Arm MAIN BURNER FACTORY SHUTTER OPENING SETTING Natural Gas Propan
Краткое содержание страницы № 8
Glowing embers (rockwool) and Volcanic stones placement ELECTRONIC Refer to the detailed glowing embers placement Sensor Pilot instructions provided in the LoG pLaceMent Hood Guide accompanying this document. Ignitor ceramic panel placement Refer to the detailed ceramic panel placement instructions provided in the LoG pLaceMent Guide accompanying this document. remote control system (deluxe) H025 rcL-t Millivolt appliance checkout deluxe remote control system The pilot flame should be ste
Краткое содержание страницы № 9
accessor Y coMponents continued pine cones and Wood Bits 9L05 FpcK Brick Liner Kits t welve piece ember Kit digital Wall thermostat The wall thermostat kit provides temperature control Model Catalog No. for optimum comfort. Description A twelve piece ember kit (model FPCK) has been No. Model No. developed to provide a means of enhancing H3961 Wall thermostat, Millivolt the already impressive log presentation of this ELDV35 Rustic BLKR-ELDV35 cat. no. Model no. description fireplace. This
Краткое содержание страницы № 10
accessor Y coMponents continued Style View Doors - Style View Doors come in 2 beautiful styles. They are easy to install and will not require hardware to attach them to the standard glass door frame. The door includes heavy duty magnet door latches and functional twin-pane doors. Arch Pane Design Square Pane Design ARCH PANE DESIGN KITS SQUARE PANE DESIGN KITS Cat. No. Model Description Model Series Cat. No. Model Description Model Series H3973 APDL40C 40” Arch Doors, Charcoal H3982 SPDL40C 40”
Краткое содержание страницы № 11
VENT TH TH TP TP WirinG diaGraMs Wiring diagrams are provided here for reference purposes only. This information is also provided on schematics attached directly to the appliance on a pullout panel located within the control compartment. caution: LaBeL aLL Wires prior to disconnection WHen serVicinG controLs. WirinG errors can cause iMproper and dan - Gerous appLiance operation. WIRING DIAGRAM MILLIVOLT GAS VALVES INTERMITTENT ELECTRONIC WIRING DIAGRAM 120 VAC SPARK TO PILOT IGNITOR THERMO
Краткое содержание страницы № 12
I O O L I P T O it TPTH TP TH L I P F L F O LiGHtinG instructions – MiLLiVoL t Gas V aLVe For Your saFetY read BeFore LiGHtinG WarninG: iF You do not FoLLoW tHese instructions exactLY, a Fire or expLosion Ma Y resuL t causinG propertY daMaGe, personaL injur Y or Loss oF LiFe. a. This appliance has a pilot which must be lighted with a piezo • Do not use any phone in your building. ignitor. When lighting the pilot, follow these instructions • Immediately call your gas supplier from a neighbor’s
Краткое содержание страницы № 13
I O O L I P T O it TPTH TP TH L I P F L F O instructions d’aLLuMaGe – V anne Gaz MiLLiVoL t pour Votre sÉcurit É, Lisez ces instructions aVant L’aLLuMaGe aVertisseMent : si Vous ne suiVez pas ces instructions à La Lettre, iL pourrait s’en suiVre un incendie ou une expLosion causant des doMMaGes MatÉrieLs, des BLessures corporeLLes ou MêMe des pertes de Vie. • Appelez immédiatement votre compagnie de gaz en utilisant le télé- a. Cet appareil est muni d’une veilleuse qui doit être allumée avec
Краткое содержание страницы № 14
VENT TH TH TP TP LiGHtinG instructions — eLectronic For Your saFetY read BeFore LiGHtinG WarninG: iF You do not FoLLoW tHese instructions exactLY, a Fire or expLosion Ma Y resuL t causinG propertY daMaGe, personaL injur Y or Loss oF LiFe. • Immediately call your gas supplier from a neighbor’s a. When lighting the appliance, follow these instructions phone. exactly. • If your gas supplier cannot be reached, call the fire B. BeFore operatinG smell all around the appliance area department. for
Краткое содержание страницы № 15
VENT TH TH TP TP instructions d’aLLuMaGe — eLectronic pour Votre sÉcurit É, Lisez ces instructions aVant L’aLLuMaGe aVertisseMent : si Vous ne suiVez pas ces instructions à La Lettre, iL pourrait s’en suiVre un incendie ou une expLosion causant des doMMaGes MatÉrieLs, des BLessures corporeLLes ou MêMe des pertes de Vie. a. Lorsque vous allumez l’appareil, suivez exactement ces instruc- • Appelez immédiatement votre compagnie de gaz en utilisant tions. le téléphone du voisin. • S’il vous est
Краткое содержание страницы № 16
TROUBLESHOOTING THE MILLIVOLT GAS CONTROL SYSTEM Note: Before troubleshooting the gas control system, be sure external gas shut off valve (located at gas supply inlet) is in the “ON” position. Important: Valve system troubleshooting should only be accomplished by a qualified service technician. sYMptoM possiBLe causes correctiVe action a. Defective ignitor . Spark ignitor will not light Check for spark at electrode and pilot; if no spark and electrode (no spark at electrode). pilot after rep
Краткое содержание страницы № 17
TROUBLESHOOTING THE ELECTRONIC IGNITION SYSTEM Note: Before troubleshooting, be sure that the appliance main line gas shut-off valve, the gas control valve and the wall switch are in the “ON” position. Important: Valve system troubleshooting should only be accomplished by a qualified service technician. sYMptoM possiBLe causes correctiVe action . Nothing happens when a. Low voltage/or bad lead Check voltage on AC terminals of module an/or batteries. The value should be ON/OFF switch is tur
Краткое содержание страницы № 18
repLaceMent p arts List ELDV35 ELDV40 ELDV45 No. DESCRIPTION Part No. Qty. Part No. Qty. Part No. Qty. Gas Fireplace Assembly – – – – – – 1. Enclose, Door Assembly H4653 1 H4654 1 H4655 1 2. Log Set H4656 1 H4657 1 H4658 1 3. Burner Assembly - Natural H7203 1 H7204 1 H7204 1 Burner Assembly - Propane H7203 1 H7246 1 H7246 1 4. Gasket - Venturi 43K85 1 43K85 1 43K85 1 5. Venturi H1428 1 H1428 1 H1428 1 6. Bottom Panel H4661 1 H4662 1 H4663 1 7. Access Plate, Blower H4664 1 H4664 1 H4664 1 8. Latc
Краткое содержание страницы № 19
repLaceMent p arts 23 15 31 22 2 16 24 44 17 8 43 1 6 20 45 42 7 21 9 11 10 3 4 33 5 41 34 32 14 35 13 13 12 12 40 30 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 9
Краткое содержание страницы № 20
Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information. Printed in U.S.A. © 2006 by Lennox Hearth Products p/n 875,030M reV. B 05/2008 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 0 West t aft avenue • orange, ca 92865 20