Краткое содержание страницы № 1
DO NOT
DISCARD
Owner’s Manual
Installation and Operation
Models:
GRAND-I35
GRAND-I35-SP
SUPREME-I30
SUPREME-I30-SP
NOTICE
DO NOT DISCARD THIS MANUAL
• Important operating • Read, understand and follow • Leave this manual with
and maintenance these instructions for safe
party responsible for use
instructions included. installation and operation.
and operation.
WARNING
WARNING: If the information in these
HOT SURFACES!
instructions is not followed exactly, a fi re
Glass and other surfaces are
Краткое содержание страницы № 2
Read this manual before installing or operating this appliance. Please retain this owner’s manual for future reference. This Owner’s Manual should be retained for future A. Congratulations reference. We suggest that you keep it with your other Congratulations on selecting a Heat & Glo gas fi replace, an important documents and product manuals. elegant and clean alternative to wood burning fi replaces. The information contained in this Owner’s Manual, unless The Heat & Glo gas fi replace you h
Краткое содержание страницы № 3
Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. • WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury. • CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. • NOTICE: Used to address practices not related to personal injury. Table of Contents A. Congratulations . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Краткое содержание страницы № 4
B. Limited Lifetime Warranty Hearth & Home Technologies Inc. LIMITED LIFETIME WARRANTY Hearth & Home Technologies Inc., on behalf of its hearth brands (”HHT”), extends the following warranty for HHT gas, wood, pellet, coal and electric hearth appliances that are purchased from an HHT authorized dealer. WARRANTY COVERAGE: HHT warrants to the original owner of the HHT appliance at the site of installation, and to any transferee taking ownership of the appliance at the site of installation within
Краткое содержание страницы № 5
B. Limited Lifetime Warranty (continued) WARRANTY CONDITIONS: WARRANTY EXCLUSIONS: - - - - - This warranty is void if: LIMITATIONS OF LIABILITY: 4021-645C 12-29-10 Page 2 of 2 Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11 5
Краткое содержание страницы № 6
Listing and Code Approvals 1 1 A. Appliance Certifi cation D. High Altitude Installations NOTICE: If the heating value of the gas has been reduced, MODELS: Grand-I35, Grand-I35-SP, these rules do not apply. Check with your local gas utility Supreme-I30, Supreme-I30-SP or authorities having jurisdiction. LABORATORY: Underwriters Laboratories, Inc. (UL) When installing above 2000 feet elevation: TYPE: Vented Gas Fireplace Heater • In the USA: Reduce input rate 4% for each 1000 feet
Краткое содержание страницы № 7
User Guide Operating Instructions 2 2 • Keep remote controls out of reach of children. A. Gas Fireplace Safety • Never leave children alone near a hot fi replace, whether operating or cooling down. WARNING • Teach children to NEVER touch the fi replace. HOT SURFACES! Glass and other surfaces are hot during • Consider not using the fi replace when children will be operation AND cool down. present. Hot glass will cause burns. Contact your dealer for more information, or visit: www. • DO NOT t
Краткое содержание страницы № 8
CLEAR SPACE 3 FT. IN FRONT OF FIREPLACE C. Clear Space E. Fixed Glass Assembly WARNING! DO NOT place combustible objects in front See Section 12.H. of the fi replace or block louvers. High temperatures may start a fi re. See Figure 2.2. F. Remote Controls, Wall Controls and Wall Avoid placing candles and other heat-sensitive objects on Switches mantel or hearth. Heat may damage these objects. Follow the instructions supplied with the control installed to operate your fi replace: For safety: •
Краткое содержание страницы № 9
4. If you intend to use both an optional wired wall switch I. Before Lighting Fireplace and the RC300 remote control to operate your fi replace, Before operating this fi replace for the fi rst time, have a the wall switch will override any commands given by qualifi ed technician: the remote. • Verify all shipping materials have been removed from inside and/or underneath the fi rebox. • Review proper placement of logs, ember material and/ or other decorative materials. • Check the wiring. • Chec
Краткое содержание страницы № 10
J. Lighting Instructions (IPI) The IPI system may be operated with four AA-cell batteries. When using batteries, unplug the transformer. To prolong battery life, remove them when using the transformer. FOR YOUR SAFETY LIGHTING READ BEFORE LIGHTING INSTRUCTIONS (IPI) WARNING: If you do not follow these instructions exactly, a fi re or explosion 1. This appliance is equipped with an ignition may result causing property damage, personal injury or loss of life. device which automatically lights t
Краткое содержание страницы № 11
Lighting Instructions - Standing Pilot Ignition LIGHTING FOR YOUR SAFETY INSTRUCTIONS READ BEFORE LIGHTING 1. Open control access panel. WARNING: If you do not follow these instructions exactly, a fi re or explosion 2. Turn off all electric power to may result causing property damage, personal injury or loss of life. the appliance. 3. Push in gas control knob A. This appliance has a pilot which • If you cannot reach your gas sup- slightly and turn clockwise to “OFF”. plier, call the fi re de
Краткое содержание страницы № 12
K. After Appliance is Lit Initial Break-in Procedure • The appliance should be run three to four hours continuously on high. • Turn the appliance off and allow it to completely cool. • Remove fi xed glass assembly. See Section 12.H. • Clean fi xed glass assembly. See Section 3. • Replace the fi xed glass assembly and run continuously on high an additional 9 hours. This cures the materials used to manufacture the fi re- place. NOTICE! Open windows for air circulation during ap- pliance break-in. •
Краткое содержание страницы № 13
Maintenance and Service 3 3 Doors, Surrounds, Fronts Any safety screen or guard removed for servicing must be replaced prior to operating the appliance. Frequency: Annually By: Homeowner When properly maintained, your appliance will give you many years of trouble-free service. We recommend an- Tools needed: Protective gloves, stable work surface nual service by a qualifi ed technician. • Assess condition of screen and replace as necessary. A. Maintenance Tasks-Homeowner • Inspect for
Краткое содержание страницы № 14
B. Maintenance Tasks-Service Technician The following tasks must be performed by a qualifi ed technician. Gasket Seal and Glass Assembly Inspection Frequency: Annually By: Service Technician Tools needed: Protective gloves, drop cloth and a stable work surface. • Inspect gasket seal and its condition. • Inspect fi xed glass assembly for scratches and nicks that can lead to breakage when exposed to heat. • Confi rm there is no damage to glass or glass frame. Replace as necessary. • Verify th
Краткое содержание страницы № 15
Burner Ignition and Operation Frequency: Annually By: Service Technician Tools needed: Protective gloves, vacuum cleaner, whisk broom, fl ashlight, voltmeter, indexed drill bit set, and a manometer. • Verify burner is properly secured and aligned with pilot or igniter. • Clean off burner top, inspect for plugged ports, corrosion or deterioration. Replace burner if necessary. • Replace Glowing embers with new dime-size pieces. DO NOT block ports or obstruct lighting paths. Refer to Sectio
Краткое содержание страницы № 16
Installer Guide Getting Started 4 4 A. Typical Appliance System NOTICE: Illustrations and photos refl ect typical installations and are for design purposes only. Illustrations/diagrams are not drawn to scale. Actual product may vary from pictures in manual VERTICAL TERMINATION CAP (SECTION 8.F) VENT PIPE (SECTION 8) 3 INCH FLEX LINERS (SECTION 8) MANTEL AND MANTEL LEG SECTION 5.B AND 11.A SURROUND OR FRONT NOT SHOWN SECTION 2.D AND 8.D. HEARTH EXTENSION GAS LINE (SECTION 9) ACCESS THROUGH
Краткое содержание страницы № 17
B. Design and Installation Considerations D. Inspect Appliance and Components Heat & Glo gas inserts are designed for installations into • Carefully remove the appliance and components from solid fuel masonry or factory built fi replaces that have the packaging. been installed in accordance with the National, Provin- • The vent system components and decorative doors and cial, State and local building codes. Fireplaces are to be fronts may be shipped in separate packages. constructed of non-c
Краткое содержание страницы № 18
Fireplace Size Requirements 5 5 from the factory built fi rebox if attached with mechanical A. Minimum Fireplace Opening fasteners. Minimum fi replace opening requirements for a standard 3/4 • The metal fl oor of the solid fuel fi rebox may be removed to inch deep surround are shown in Figure 5.1. For smaller facilitate the installation of the insert. The appliance may openings, an optional 1-1/2 inch deep surround is available not be placed directly on the base of the outer wrap, a 1/
Краткое содержание страницы № 19
SIDE VIEW TOP VIEW 1-1/2 IN. B D A D C D SURROUND APPLIANCE SURROUND APPLIANCE MINIMUM FIREPLACE SIZE GRAND-I35 SUPREME-I30 Location Inches Millimeters Inches Millimeters A Alternate Unit Width 33-3/16 843 29-1/16 738 D B Alternate Unit Depth 15-1/16 383 13-7/8 352 D C Alternate Unit Height 22-9/16 573 19-1/16 484 D * Note: If exhaust collar on insert and fi replace damper do not line up, add 4 inches (102 mm) to minimum fi replace height for bends in vent pipe. Figure 5.2 Fireplace Opening - D
Краткое содержание страницы № 20
Termination Locations 6 6 A. Vent Termination Minimum Clearances AB 6 in. (minimum) up to 20 in. 18 in. minimum 152 mm/508 mm 457 mm WARNING 20 in. and over 0 in. minimum Fire Risk. Gas, Wood or Fuel Oil Maintain vent clearance to combustibles as Termination Cap specifi ed. • DO NOT pack air space with insulation or other materials. B Failure to keep insulation or other materials away from vent pipe may cause fi re. A * HORIZONTAL Gas OVERHANG Termination Cap ** 2 FT. 20 INCHES MIN. VERTICA