Краткое содержание страницы № 1
DO NOT
DISCARD
Para obtener un ejemplar en Español de este Pour demander un exemplaire en français de ce Manuel
Manual del propietario, visite www.heatnglo.com. du propriétaire, visitez www.heatnglo.com.
Owner’s Manual
Installation and Operation
Models:
SL-550TV-IPI-E
SL-750TV-IPI-E
SL-950TV-IPI-E
NOTICE
DO NOT DISCARD THIS MANUAL
• Important operating • Read, understand and follow • Leave this manual with
and maintenance these instructions for safe
party responsible for use
instructions in
Краткое содержание страницы № 2
Read this manual before installing or operating this appliance. Please retain this owner’s manual for future reference. This owner’s manual should be retained for future A. Congratulations reference. We suggest that you keep it with your other Congratulations on selecting a Heat & Glo gas fi replace, an important documents and product manuals. elegant and clean alternative to wood burning fi replaces. The information contained in this owner’s manual, unless The Heat & Glo gas fi replace you h
Краткое содержание страницы № 3
Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. • WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury. • CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. • NOTICE: Used to address practices not related to personal injury. Table of Contents A. Congratulations . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Краткое содержание страницы № 4
14 Appliance Setup A. Remove Glass Assembly . . . . . . . . . . . . . . . . . . . . . . . . . 33 B. Remove the Shipping Materials . . . . . . . . . . . . . . . . . . . . 33 C. Clean the Appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 D. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 E. Lava Rock, Mineral Wool/Ember Placement . . . . . . . . . . 33 F. Install the Log Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . 34 G. Fi
Краткое содержание страницы № 5
B. Limited Lifetime Warranty Heat & Glo • SL-550 / 750 / 950TV-IPI-E • 2119-900 Rev. J • 12/09 5
Краткое содержание страницы № 6
B. Limited Lifetime Warranty (continued) 6 Heat & Glo • SL-550 / 750 / 950TV-IPI-E • 2119-900 Rev. J • 12/09
Краткое содержание страницы № 7
Listing and Code Approvals 1 1 A. Appliance Certifi cation C. BTU Specifi cations Orifi ce Maximum Minimum Model(s) MODELS: SL-550TV-IPI-E, SL-750TV-IPI-E, SL-950TV-IPI-E Size Input BTU/h Input BTU/h U.S. (0-2000 ft.) or Canada (2000-4500 ft.) (DMS) LABORATORY: Underwriters Laboratories, Inc. (UL) TYPE: B-Vent Gas Appliance US 21,100 14,700 44 SL-550TV-IPI-E STANDARD: ANSI Z21.50-2007 • CSA 2.22-2007 CAN 18,990 13,230 45 US 20,000 14,300 55 This product is listed to ANSI standards for “Vent
Краткое содержание страницы № 8
D. High Altitude Installations NOTICE: If the heating value of the gas has been reduced, these rules do not apply. Check with your local gas utility or authorities having jurisdiction. When installing above 2000 feet elevation: • In the USA: Reduce input rate 4% for each 1000 feet above 2000 feet. • In CANADA: Reduce input rate 10% for elevations between 2000 feet and 4500 feet. Above 4500 feet, consult local gas utility. Check with your local gas utility to determine proper orifi ce size.
Краткое содержание страницы № 9
User Guide Operating Instructions 2 2 • Keep remote controls out of reach of children. A. Gas Fireplace Safety • Never leave children alone near a hot fi replace, whether operating or cooling down. WARNING • Teach children to NEVER touch the fi replace. HOT SURFACES! Glass and other surfaces are hot during • Consider not using the fi replace when children will be operation AND cool down. present. Hot glass will cause burns. Contact your dealer for more information, or visit: www. • DO NOT t
Краткое содержание страницы № 10
CLEAR SPACE 3 FT. IN FRONT OF FIREPLACE C. Fan Kit (optional) E. Decorative Doors and Fronts • Refer to Figures 2.2 and 2.3 for location of control. WARNING! Risk of Fire! Install ONLY doors or fronts approved by Hearth & Home Technologies. Unapproved doors or fronts may cause fi replace to overheat. This fireplace has been supplied with an integral barrier to prevent direct contact with the fi xed glass panel. DO NOT operate the fi replace with the barrier removed. Contact your dealer or He
Краткое содержание страницы № 11
I. Lighting Instructions (IPI) The IPI system may be operated with two D-cell batteries. When using batteries, unplug the transformer. To prolong battery life, remove them when using the transformer. FOR YOUR SAFETY LIGHTING READ BEFORE LIGHTING INSTRUCTIONS (IPI) WARNING: If you do not follow these instructions exactly, a fi re or explosion 1. This appliance is equipped with an ignition may result causing property damage, personal injury or loss of life. device which automatically lights th
Краткое содержание страницы № 12
J. After Fireplace is Lit Initial Break-in Procedure • The fireplace should be run three to four hours continuously on high. • Turn the fi replace off and allow it to completely cool. • Remove fi xed glass assembly. See Section 14.G. • Clean fi xed glass assembly. See Section 3. • Replace the fi xed glass assembly and run continuously on high an additional 12 hours. This cures the materials used to manufacture the fi re- place. NOTICE! Open windows for air circulation during fi re- place break-in. •
Краткое содержание страницы № 13
Maintenance and Service 3 3 Doors, Surrounds, Fronts Any safety screen or guard removed for servicing must be replaced prior to operating the fi replace. Frequency: Annually By: Homeowner When properly maintained, your fi replace will give you many years of trouble-free service. We recommend an- Tools needed: Protective gloves, stable work surface nual service by a qualifi ed service technician. • Assess condition of screen and replace as necessary. A. Maintenance Tasks-Homeowner • Ins
Краткое содержание страницы № 14
Venting Control Compartment and Firebox Top Frequency: Seasonally Frequency: Annually By: Homeowner By: Qualifi ed Service Technician Tools needed: Protective gloves and safety glasses. Tools needed: Protective gloves, vacuum cleaner, dust cloths • Inspect venting and termination cap for blockage or obstruction such plants, bird nests, leaves, snow, debris, • Vacuum and wipe out dust, cobwebs, debris or pet hair. etc. Use caution when cleaning these areas. Screw tips that have penetrated
Краткое содержание страницы № 15
(Either cobrahead or SIT) Figure 3.1 IPI Pilot Flame Patterns Heat & Glo • SL-550 / 750 / 950TV-IPI-E • 2119-900 Rev. J • 12/09 15 PRODUCT SPECIFIC
Краткое содержание страницы № 16
Installer Guide Getting Started 4 4 A. Typical Appliance System NOTICE: Illustrations and photos refl ect typical installations and are for design purposes only. Illustrations/diagrams are not drawn to scale. Actual product may vary from pictures in manual VERTICAL TERMINATION CAP (SECTION 4.D) NON-COMBUSTIBLE ROOF FLASHING MAINTAINS MINIMUM CLEARANCE AROUND PIPE STORM COLLAR (SECTION 4.D) VENT PIPE PENETRATES ROOF PREFERABLY WITHOUT AFFECTING ROOF RAFTERS (SECTION 8.B) VENT PIPE (SECTIO
Краткое содержание страницы № 17
• The vent system components and decorative doors and B. Design and Installation Considerations fronts may be shipped in separate packages. Heat & Glo B-type vent gas appliances are designed to • If packaged separately, the log set and appliance grate operate with all exhaust gases expelled to the outside of must be installed. the building, and combustion air pulled from the room. • Report to your dealer any parts damaged in shipment, Installation MUST comply with local, regional, state a
Краткое содержание страницы № 18
• Ensure adequate outdoor air is supplied for combustion E. Negative Pressure appliances and exhaust equipment. WARNING! Risk of Asphyxiation! Negative pressure • Ensure furnace and air conditioning return vents are not can cause spillage of combustion fumes and soot. Fire- located in the immediate vicinity of the fi replace. place needs to draft properly for safety. • Avoid installing the fi replace near doors, walkways or Draft is the pressure difference needed to vent fi replaces small isol
Краткое содержание страницы № 19
Framing and Clearances 5 5 NOTICE: Illustrations refl ect typical installations and are A. Selecting Appliance Location FOR DESIGN PURPOSES ONLY. Illustrations/diagrams When selecting a location for the appliance it is important to are not drawn to scale. Actual installation may vary due to consider the required clearances to walls (see Figure 5.1). individual design preference. WARNING! Risk of Fire or Burns! Provide adequate clearance around air openings and for service access. Due to
Краткое содержание страницы № 20
To further prevent drafts, the wall shield and ceiling fi re- B. Constructing the Appliance Chase stops should be caulked with high temperature caulk to A chase is a vertical box-like structure built to enclose the seal gaps. Gas line holes and other openings should be gas appliance and/or its vent system. In cooler climates caulked with high temp caulk or stuffed with unfaced in- the vent should be enclosed inside the chase. sulation. If the appliance is being installed on a cement NOTICE: