Краткое содержание страницы № 1
Model:
Installers Guide
BE-41
Underwriters
Laboratories Listed
READ THIS MANUAL BEFORE INSTALLING OR
OPERATING THIS APPLIANCE. THIS INSTALLERS
WARNING: IF THE INFORMATION
GUIDE MUST BE LEFT WITH APPLIANCE FOR
FUTURE REFERENCE.
IN THESE INSTRUCTIONS IS NOT
FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUS-
WARNING: IMPROPER INSTALLA-
ING PROPERTY DAMAGE, PER- TION, ADJUSTMENT, ALTERATION,
SONAL INJURY, OR DEATH. SERVICE OR MAINTENANCE CAN
CAUSE INJURY OR PROPERTY DAM-
- Do not store or use g
Краткое содержание страницы № 2
SAFETY AND WARNING INFORMATION These units MUST use one of the vent systems READ and UNDERSTAND all instructions carefully ! ! described in the Installing the Fireplace section of before starting the installation. FAILURE TO the Installers Guide. NO OTHER vent systems or FOLLOW these installation instructions may result components MAY BE USED. in a possible fire hazard and will void the warranty. This gas fireplace and vent assembly MUST be Prior to the first firing of the fireplace, READ the !
Краткое содержание страницы № 3
TABLE OF CONTENTS Safety and Warning Information ................................................ 2 Service Parts Lists ..................................................................... 4 Section 1: Approvals and Codes ............................................... 6 Approval Listings and Codes ........................................................ 6 Appliance Certification................................................................... 6 Installation Codes ............................
Краткое содержание страницы № 4
Service Parts BE-41 (NG, LP) Exploded Parts Diagram / Vue éclatée des pièces 10 9 2 1 3 4 8 7 5 6 Log Set Assembly Part number list on following page. * La liste des numéros de pièce se * trouve à la page suivante. 4
Краткое содержание страницы № 5
BE-41 Service Parts List / Liste des pièces de rechange IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts. ITEM / STANDING PILOT AND DSI IGNITION COMMON PARTS SERIAL # / N° PART NUMBER PIÈCE / UNE VEILLEUSE ET ALLUMAGE DSI PIÉCES COMMUNES DE SÉRIE / N° DE PIÈCE Piezo Ignitor / Allumage Piézo 418-513 Burner Orifice NG (#38) / Orifice de brûleur GN (#38) 05
Краткое содержание страницы № 6
Approvals and Codes 1 High Altitude Installations Appliance Certification The Heat-N-Glo fireplace models discussed in this Installers U.L. Listed gas fireplaces are tested and approved for Guide have been tested to certification standards and listed elevations from 0 to 2,000 feet in the U.S.A. and from 0 to by the applicable laboratories. 4,500 feet in Canada. When installing this fireplace at an elevation above 2,000 feet (in the United States), it may be necessary to decrease Certification t
Краткое содержание страницы № 7
Getting Started 2 Introducing the Heat-N-Glo Gas Fireplaces The vent system components and trim doors are shipped Heat-N-Glo direct vent gas fireplaces are designed to oper- ate with all combustion air siphoned from outside of the in separate packages. The gas logs may be packaged building and all exhaust gases expelled to the outside. separately and must be field installed. The information contained in this Installers Guide, unless Read all of the instructions before starting the noted otherwi
Краткое содержание страницы № 8
When planning a fireplace installation, its necessary to The Heat-N-Glo Warranty will be voided by, and Heat-N-Glo determine: disclaims any responsibility for, the following actions: Where the unit is to be installed. Installation of any damaged fireplace or vent system component. The vent system configuration to be used. Modification of the fireplace or direct vent system. Gas supply piping. Installation other than as instructed by Heat-N-Glo. Electrical wiring. Improper positi
Краткое содержание страницы № 9
Minimum Clearances from the Fireplace to Combustible Materials Inches mm Glass Front ........................ 36 .................... 914 Installing the Fireplace Floor ................................... 0 ....................... 0 3 Rear ...................................1/2 ..................... 13 Sides .................................1/2 ..................... 13 Top ................................... 3 1/2 ................... 89 Step 1. Locating the Fireplace Ceiling* ............
Краткое содержание страницы № 10
Step 2. Framing the Fireplace Fireplace framing can be built before or after the fireplace is CAUTION: MEASURE FIREPLACE DIMENSIONS AND set in place. Framing should be positioned to accommo- VERIFY FRAMING METHODS AND WALL COVERING date wall coverings and fireplace facing material. The dia- DETAILS BEFORE FRAMING. gram below shows framing reference dimensions. Shows center of 12 x 12 vent framing SHOWS CENTER OF12" X 12" holes for top and rear venting. The center VENT FRAMING HOLES FOR of the
Краткое содержание страницы № 11
6 7/16” (164mm) 8 1/2” (216mm) 8 1/2” (216mm) 11 1/16” 5 7/8” 7 3/8” (281mm) (149mm) (187mm) 6 1/2” 5 1/16” (165mm) (129mm) 8 5/8” 8 5/8” (220mm) (220mm) 11 15/16” (303mm) DV-90D DV-48D DV-36D DV17/24D DV-12/17D 17-24 (432-610mm) 35 3/4” (908mm) 47 3/4” (1.2m) 11 3/4” 8 3/4” (298mm) (222mm) 5 3/4” (146mm) DV-09D DV-12D DV-06D NOTE: PIPES OVERLAP 1-3/8 INCHES (34.93mm) AT EACH JOINT. Figure 4. D-Series Direct Vent Component Specifications (5-inch inner pipe / 8 5/8-inch outer pi
Краткое содержание страницы № 12
Step 3. Installing the Vent System A. Vent System Approvals Identifying Vent Components These models are approved to use D-series direct vent pipe The vent systems installed on this gas fireplace may in- components and terminations (see Figures 4 and 5). Ap- clude one, two, or three 90° elbow assemblies. The rela- proved vent system components are labeled for identifica- tionships of vertical rise to horizontal run in vent configura- tion. This pipe is tested and listed as an approved compo-
Краткое содержание страницы № 13
HORIZONTAL VENTING Kit No. H Max. Run DVK-01D DVK-01TRD 24" (610 mm) STRAIGHT UP VERTICAL VENTING V (FT.) H 40' MAX. (12.4 M) 90-DEGREE ELBOWS 45-DEGREE ELBOW Figure 6. Straight Up Vertical Venting NOTE: BE-41 model is tested and approved to use 45° elbows in corner installations. NOTE: On vertical venting configurations where the vertical However, 90° elbows will result in better per- component is over 10 feet, you may want to install the formance. vertical baffle (VERT-BAF) (see Figure 7
Краткое содержание страницы № 14
VENTING WITH ONE (1) 90° ELBOW V H 1' MIN. (305mm) 2' MAX. (610mm) 2' MIN. (610mm) 4' MAX. (1.22m) 3' MIN. (914mm) 6' MAX. (1.86m) 4' MIN. (1.22m) 8' MAX. (2.4m) V+H=40' MAX. (12.4m) H = 8' MAX. (2.4m) NOTE: On vertical venting configurations where the vertical component is over 10 feet, you may want to install the vertical baffle (VERT-BAF) improve flame appearance. Figure 9. Venting with One 90° Elbow VENTING WITH ONE (1) 90° ELBOW V (FT.)
Краткое содержание страницы № 15
VENTING WITH TWO (2) 90° ELBOWS V H H + H 1 1´ MIN. (305 mm) 2´ MAX. (610 mm) 5´ MAX. (1.52m) 2´ MIN. (610 mm) 4´ MAX. (1.22 m) 10´ MAX. (3.1m) 3´ MIN. (914 mm) 6´ MAX. (1.86 m) 15´ MAX. (4.65m) 4´ MIN. (1.22 m) 8´ MAX. (2.48 m) 20´ MAX. (6.2m) V+H+H1 = 40´ MAX. (12.4 m) H = 8´ MAX. (2.48 m) H+H1 = 20´ MAX. (6.2m) Figure 11. Venting with Two 90° Elbows o VENTING WITH TWO (2) 90 ELBOWS V FT. H + H (FT.) 1 1' MIN. (305mm) 5´ MAX. (1.52m) 2' MIN. (610mm) 10´ MAX. (3.1m) 3' MIN.
Краткое содержание страницы № 16
VENTING WITH THREE (3) 90° ELBOWS V H H + H 1 1´MIN. (305mm) 2´MAX. (610mm) 5´MAX. (1.52m) 2´MIN. (610mm) 4´MAX. (1.22m) 10´MAX. (3.1m) 3´MIN. (914mm) 6´MAX. (1.86m) 15´MAX. (4.65m) 4´MIN. (1.22m) 8´MAX. (2.48m) 20´MAX. (6.2m) V +V+H+H = 40´ MAX.(12.4 m) H = 8´MAX.(2.48 m) H+H = 20´MAX.(6.2 m) 1 1 1 V H H + H + H 1 2 1´MIN. (305mm) 2´MAX. (610mm) 5´MAX. (1.52m) 2´MIN. (610mm) 4´MAX. (1.22m) 10´MAX. (3.1m) 3´MIN. (914mm) 6´MAX. (1.
Краткое содержание страницы № 17
VENTING WITH THREE (3) 90° ELBOWS V (FT.) H (FT.) 1' MIN. (305mm) 5' MAX. (1.52m) 2' MIN. (610mm) 10' MAX. (3.1m) 3' MIN. (914mm) 15' MAX. (4.65m) 4' MIN. (1.22m) 20' MAX. (6.2m) NOTE: H + H = 20' MAX. (6.2m) 1 V + V + H + H = 40' MAX. (12.4m) 1 1 V (FT.) H + H (FT.) 1 1' MIN. (305mm) 5' MAX. (1.52m) 2' MIN. (610mm) 10' MAX. (3.1m) 3' MIN. (914mm) 15' MAX. (4.65m) 4' MIN. (1.22m) 20' MAX. (6.2m) H +H = 20' MAX. (6.2m) 1 NOTE: V+V +H +H = 40' MAX. (12.4m) 1 1 Fi
Краткое содержание страницы № 18
B. Installing Vent Components 1. Attach the First Vent Component to the Starting Collars After determining which set of starting collars will be used (top or rear), follow venting instructions accordingly. To attach the first vent component to the starting collars of the fireplace: Venting Out the Rear Vent Remove the installed rear seal cap from the rear starting collars by cutting the strap at each end. (see Figure 15). Apply a 3/8 inch (9.5mm) bead of stove cement around Follow the
Краткое содержание страницы № 19
2. Continue Adding Vent Components For Vertical Runs - The vent system must be supported every eight (8) feet (2.4m) above the fireplace flue outlet by Continue adding vent components, locking each succeed- wall brackets. ing component into place. To install support brackets for vertical runs: Ensure that each succeeding vent component is secure- ly fitted and locked into the preceding component in the Attach wall brackets to the vent pipe and secure the wall vent system. bracket to the fr
Краткое содержание страницы № 20
Position the firestops on both sides of the hole previ- For Vertical Runs - One ceiling firestop is REQUIRED at ously cut and secure the firestops with nails or screws. the hole in each ceiling through which the vent passes. To install firestops for vertical runs that pass through ceilings: The heat shields of the firestops MUST BE placed to- wards the top of the hole. Position a plumb bob directly over the center of the verti- cal vent component. Continue the vent run through the firest