Краткое содержание страницы № 1
DO NOT
DISCARD
Owner’s Manual
Installation and Operation
Model(s):
PALOMA-BL
Portland
Tested and
O-T L
PALOMA-BZ Listed by Oregon USA
C US
PALOMA-GR
OMNI-Test Laboratories, Inc.
PALOMA-GY
CAUTION
DO NOT DISCARD THIS MANUAL
• Important operating • Read, understand and follow • Leave this manual with
and maintenance these instructions for safe
party responsible for use
instructions included. installation and operation.
and operation.
WARNING
WARNING: If the information in these
HOT SURFACES!
Краткое содержание страницы № 2
Read this manual before installing or operating this appliance. Please retain this owner’s manual for future reference. Congratulations Congratulations on selecting a Heat & Glo gas appliance This Owner’s Manual should be retained for future —an elegant and clean alternative to wood burning reference. We suggest that you keep it with your other important documents and product manuals. appliances. The Heat & Glo gas appliance you have selected is designed to provide the utmost in safety, The
Краткое содержание страницы № 3
Table of Contents 1 Listing and Code Approvals 8 Appliance Setup A. Appliance Certifi cation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 A. Remove Shipping Materials . . . . . . . . . . . . . . . . . . . . . . . 33 B. Glass Specifi cations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 B. Unbolting Appliance from the Pallet . . . . . . . . . . . . . . . . . 33 C. BTU Specifi cations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 C. Leveling and Laggi
Краткое содержание страницы № 4
Listing and Code Approvals 1 1 A. Appliance Certifi cation D. High Altitude Installations Omni-Test Laboratories, Inc. listed gas appliances are MODELS: Paloma tested and approved without requiring changes for elevations from 0 to 2000 feet in the U.S.A. and 0 to 4500 LABORATORY: Omni Test Laboratories, Inc. feet in Canada. TYPE: Vented Gas Fireplace Heater When installing this appliance at an elevation above 2000 STANDARD: ANSI Z21.88B-2003 • CSA 2.33-2003 • UL307B feet, it may be nece
Краткое содержание страницы № 5
Inspection Note: The following requirements reference various The state or local gas inspector of the side wall horizon- Massachusetts and national codes not contained in this tally vented gas fueled equipment shall not approve the document. installation unless, upon inspection, the inspector ob- serves carbon monoxide detectors and signage installed H. Requirements for the Commonwealth of in accordance with the provisions of 248 CMR 5.08(2)(a)1 Massachusetts through 4. For all side wall
Краткое содержание страницы № 6
Getting Started 2 2 A. Design and Installation Considerations C. Inspect Appliance and Components Heat & Glo direct vent gas appliances are designed to operate with all combustion air siphoned from outside of WARNING the building and all exhaust gases expelled to the outside. Inspect appliance and components for damage. No additional outside air source is required. Damaged parts may impair safe operation. • Do NOT install damaged components. • Do NOT install incomplete components. CAUTIO
Краткое содержание страницы № 7
Framing and Clearances 3 3 Note: WARNING • Illustrations reflect typical installations and are FOR Fire Risk DESIGN PURPOSES ONLY. Provide adequate clearance: • Illustrations/diagrams are not drawn to scale. • Around air openings • Actual installation may vary due to individual design preference. • To combustibles • For service access A. Selecting Appliance Location Locate appliance away from traffi c areas. When selecting a location for your appliance it is important to NOTE: For actual
Краткое содержание страницы № 8
C. Optional Stone Surround Installed E C G B F D A A G Model A B C D E F G Inches 3-1/4 4 30-3/4 36 1 20* 4-3/4 Paloma Surround Millimeters 83 102 781 914 25 508 121 *Distance is measured from fl ue collar to corner Figure 3.1 It is permissible to place the appliance on carpet. WARNING Fire Risk. CAUTION • Locate and install appliance to all clearance specifi cations in manual. Some carpet materials may be sensitive to radiant heat from the appliance causing discoloration or odor. WARNING Not
Краткое содержание страницы № 9
Termination Locations 4 4 A. Vent Termination Minimum Clearances HORIZONTAL OVERHANG WARNING 2 FT. 20 INCHES MIN. VERTICAL MIN. WALL LOWEST Fire Risk. DISCHARGE OPENING Explosion Risk. GAS DIRECT VENT Maintain vent clearance to combustibles as TERMINATION CAP specifi ed. X • Do not pack air space with insulation or other 12 materials. ROOF PITCH Failure to keep insulation or other materials IS X/ 12 away from vent pipe may cause fi re. H (MIN.) - MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARG
Краткое содержание страницы № 10
M N P R Q (See Note 2) V T S S Electrical V V Service D* V = VENT TERMINAL X V = AIR SUPPLY INLET = AREA WHERE TERMINAL IS NOT PERMITTED A = 12 inches.................clearances above grade, veranda, L** = 7 ft. ......................... clearance above paved (See Note 1) (See Note 1) porch, deck or balcony sidewalk or a paved driveway located on public property B = 12 inches.................clearances to window or door M*** = 18 inches................ clearance under veranda, porch, that
Краткое содержание страницы № 11
Vent Information 5 5 A. Venting Components B. Use of Elbows In order to comply with applicable codes and product warranties, use only following venting components: CAUTION • Hearth & Home Technologies (HHT) ALL vent confi guration specifi cations MUST be followed. • Simpson Dura-Vent (SDV) • This product is tested and listed to these specifi cations. DO NOT USE FIELD-FABRICATED VENTING COMPO- • Appliance performance will suffer if specifi cations are not NENTS. Refer to the venting manuf
Краткое содержание страницы № 12
D. How to Use the Vent Graph E. Venting Guidelines 1. Measure the distance from the top of appliance to the • The maximum horizontal vent run is 15 ft. (5 m) when center of the 90° elbow. On the graph below, draw a the vertical vent rise is 10 ft. (3 m). horizontal line from that measurement on the vertical • The minimum horizontal vent run is 11-5/8 in. (295 axis across until it intersects with the slanted line. mm). 2. From the point of this intersection, draw a vertical line • Horizontal
Краткое содержание страницы № 13
2. Direct vent pipe is designed with a locking connection. F. Horizontal Termination To connect the venting system to the appliance flue outlet, a twist-lock adapter is built into the appliance TERMINATION CAP at the factory. Wall thickness may vary. Remember to include wall thickness in minimum clearances when figuring venting lengths for your installation needs. 90º ELBOW 3. Female ends of direct vent pipe/elbows are designed to slide straight onto the male ends of adjacent pipes PIPE
Краткое содержание страницы № 14
WOOD SCREW CENTER OF HOLE CENTER LINE CENTER LINE WALL THIMBLE PART HHW2 #841-0670 HOT (PREFERRED) WALL THIMBLE Figure 5.6 8. The four wood screws provided should be replaced Figure 5.5 with appropriate fasteners for stucco, brick, concrete, or other types of sidings. 5. Installation requires a minimum of 6 in. (152 mm) 9. Termination cap HHW2 (Part #841-0670) is highly horizontal run of vent with a 1/4 in. (6 mm) rise run recommended on a building with vinyl siding, as the towards the t
Краткое содержание страницы № 15
VINYL SIDING WARNING Fire Risk APPLY SEALANT TO ALL FOUR SIDES Exhaust Fumes Risk Impaired Performance of Appliance SCREWS • Ensure vent components are locked together correctly. • Pipe may separate if not properly joined. BOLT HORIZONTAL TOP TO VINYL STANDOFF WARNING SCREWS WALL Do NOT connect a pipe section to a termination cap THIMBLE VINYL SIDING STANDOFF WITH without using the telescoping flue section found on the COVER SIDING BENEATH REMOVED termination cap. WALL THIMBLE Figure 5.
Краткое содержание страницы № 16
G. Vertical Termination VERTICAL TERMINATION CAP USE PART #SLK-991DA STORM COLLAR FLASHING 40 ft. (12 m) MAXIMUM FIRESTOP SUPPORT BOX PIPE LENGTH Figure 5.11 2. Set the gas appliance in its desired location. Drop a plumb bob down from the ceiling to the position of the appliance flue exit, and mark the location where the vent will penetrate the ceiling. Drill a small hole at this point. Next, drop a plumb bob from the roof to the hole previously drilled in the ceiling, and mark the On
Краткое содержание страницы № 17
3. To install the round support box/wall thimble cover in a flat ceiling, cut a 10 in. (254 mm) square hole in the ceiling, centered on the hole drilled in Step 2. Frame SHINGLES OVERLAP ON the hole as shown in Figure 5.13. CAP AND STORM TOP EDGE OF FLASHING COLLAR NOT SHOWN FOR CLARITY CEILING JOISTS FRAMING ROUND CEILING SUPPORT BOX/WALL THIMBLE COVER Figure 5.14 1-1/2 in. (38 mm) 7. Continue to assemble pipe sections until the height of LONG WOOD SCREWS the vent (before adding the
Краткое содержание страницы № 18
9. Twist-lock the vent cap and seal. Note: For multi-story vertical installations, a ceiling firestop is required at the second floor, and any subsequent floors (Figure 5.16). The opening should be framed to 10 in. x 10 in. (254 mm x 254 mm) inside dimensions, in the same manner as shown in Figure 5.13. NAILS CEILING FIRESTOP MINIMUM 1 in.(25 mm) CLEARANCE MINIMUM 1 in.(25 mm) CLEARANCE MINIMUM 1 in. (25 mm) CLEARANCE MINIMUM 1 in.(25 mm) CLEARANCE Figure 5.16 WARNING Fire Risk. Explosion Ri
Краткое содержание страницы № 19
H. Cathedral Ceiling 1. Follow installation Steps 1 and 2 under vertical instal- lation section, page 16. 2. Remove shingles or other roof covering as necessary to cut the rectangular hole for the support box. Cut the hole 1/8 in. (3 mm) larger than the support box outline. 3. Lower the support box through the hole in the roof until the bottom of the support box protrudes at least 2 in. (51 mm) below the ceiling (Figure 5.17). Align the support box both vertically and horizontally with a l
Краткое содержание страницы № 20
4. Pass the flex pipe down through the center of the I. Class A Metal Chimney chimney system, and center the top adapter on the top of the chimney pipe. Drill four 1/8 in. (3 mm) diameter TERMINATION holes through the top adapter, and into the chimney CAP PART #SLK-991DA top. Ensure that you are drilling into the metal on the chimney. Twist lock the high wind termination cap onto the top adapter (Figures 5.22 and 5.23). TOP ADAPTER FLASHING EXISTING METAL CHIMNEY SYSTEM 4 in. (102 mm)