Краткое содержание страницы № 1
INSTALLATION AND OPERATION
INSTRUCTIONS
MODEL: GRL-850-AU
AUSTRALIAN GAS ASSOCIATION APPROVED
Approval Number 5837
THIS MANUAL MUST BE USED FOR INSTALLATION AND RETAINED
BY HOMEOWNER FOR OPERATION AND MAINTENANCE.
HEAT-N-GLO, a brand of Hearth & Home Technologies Inc.
20802 Kensington Boulevard, Lakeville, MN 55044, U.S.A. • (952) 985-6000
This product is covered by one or more of the following patents: (United States) 4,112,913; 4,408,594; 4,422,426; 4,424,792; 4,520,791; 4,793,322; 4,852,548;
Краткое содержание страницы № 2
INSTALLATION AND OPERATION INSTRUCTIONS PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING THIS APPLIANCE. MODEL GRL-850-AU IS AUSTRALIAN them will void your warranty and may present GAS ASSOCIATION APPROVED FOR a fire hazard. NATURAL GAS OR PROPANE AS A The Heat-N-Glo, a brand of Hearth & Home DECORATIVE GAS LOG. Technologies Inc. warranty will be voided by, and Heat-N-Glo, a brand of Hearth & Home Refer to the appliance data plates for gas Technologies Inc. disclaims any responsibil- consumpt
Краткое содержание страницы № 3
Table of Contents 1.0 INTRODUCTION .........................................................................................................5 2.0 ASSEMBLY.................................................................................................................5 GAS LINE CONNECTION .........................................................................................6 u LOG PLACEMENT ................................................................................................... 7 3.
Краткое содержание страницы № 4
FRONT SURROUND PILOT REAR ASSEMBLY SURROUND BURNER PIEZO IGNITOR DECORATIVE FRONT SIDE SURROUND CONTROL ACCESS COVER ON/OFF GAS SWITCH FLEX TUBE VALVE TOP VIEW - FIREPLACE AREA DEPTH TOP VIEW NOTE: Unit must be 33mm back from WIDTH fireplace front. 33mm MINIMUM FIREPLACE OPENING Minimum Maximum WIDTH: 850mm 1050mm DEPTH: 300mm 460mm HEIGHT: 425mm 540mm 300mm DEPTH u FIGURE 1 4
Краткое содержание страницы № 5
CAUTION: DO NOT PLACE ARTICLES ON OR 1.0 INTRODUCTION AGAINST THIS APPLIANCE. Model GRL-850-AU Gas Log Sets are Decorative Gas CAUTION: DO NOT USE OR STORE FLAMMABLE Appliances for Installation in a Solid-Fuel Burning Fire- MATERIALS NEAR THIS APPLIANCE. place. Minimum fireplace size for GRL-850-AU: height 425mm, width 850mm, depth 300mm. CAUTION: DO NOT SPRAY AEROSOLS IN THE VI- CINITY OF THIS APPLIANCE WHILE IT IS IN OP- This log set is to be installed only in a solid-fuel burn- ERATION. ing f
Краткое содержание страницы № 6
E. NOTE: An Optional Remote Control Kit and Wall A. Inlet gas supply pressure for purposes of input ad- Switch Kit , for turning the burner ON/OFF are avail- justment, shall be 6.0 inches w.c. (1.5kPa) for natu- able. Detailed installation instructions are found in ral gas and 11 inches w.c. (2.75kPa) for propane. each kit. Manifold (outlet) pressure should be 3.2 inches w.c. (.80kPa) for natural gas and 9.6 inches w.c. (2.40kPa) F. Test fire the unit after referring to the SAFETY IN- for propa
Краткое содержание страницы № 7
u LOG PLACEMENT Log Set Assembly: GRL-850-AU-LOGS INSTRUCTIONS Model: GRL-850-AU STEP 1: Attach grate to as- sembly by sliding hooks into open- FRONT ings on the front surround. SURROUND PILOT REAR ASSEMBLY SURROUND BURNER PIEZO IGNITOR STEP 2: Ensure that tabs on the rear and side surround are bent DECORATIVE FRONT as shown in Figure 1. Carefully remove logs from carton and place SIDE SURROUND CONTROL as shown. ACCESS COVER ON/OFF GAS SWITCH VALVE FLEX TUBE Figure 1 1 3 2 4 5 7 6 CAUTION: L
Краткое содержание страницы № 8
Heat-n-Glo GRL-700/GRL-850 Glowing Embers (Mineral Wool) Placement Natural Gas • Place single layer of 10mm circular sized pieces next to burner ports, taking care not to place material on or between ports. • Do not use all of the ‘ember’ in the packet. One packet should last 5-6 applications. • Repeat application at the start of each season or at the next fireplace service (annually). Note: The contents of the bag is intended for multiple applications. D
Краткое содержание страницы № 9
Heat-n-Glo GRL-700/GRL-850 Glowing Embers (Mineral Wool) Placement LPG • Place single layer of 10mm circular sized pieces on top of burner ports. • Increase the quantity of the “glowing embers” on the right, centre and left hand side, as indicated, of the burner where there is a cluster of burner ports. • Do not use all of the ‘ember’ in the packet. One packet should last 4-5 applications. • Repeat application at the start of each season or at the next fireplace service (a
Краткое содержание страницы № 10
1 1 STEP 3: LOG #1 (SRV2011-707) Put log #1 behind the locating tab on the right rear corner and up against the locating tab in the center. 2 2 STEP 4: LOG #2 (SRV530-717) Place log #2 on the left front corner of the grate using its locating groove and tab. 3 3 STEP 5: LOG #3 (SRV2011-703) Place log #3 onto the center of the burner using its locating tabs and slot. 8
Краткое содержание страницы № 11
4 4 STEP 6: LOG #4 (SRV568-706) Rest log #4 in the front right hand side between log #3 and the right edge of the set. 5 5 STEP 7: LOG #5 (SRV720-722) Rest log #5 on log #2 and rest the top in the grove on log #1. 6 6 248mm STEP 8: LOG #6 (SRV347-712) Place log #6 in the groove on top of log #1 with its front on log #2. The left front edge of log #6 must be located 248mm from the left decorative front corner. 9
Краткое содержание страницы № 12
7 7 STEP 9: LOG #7 (SRV571-707) Place log #7 in the groove on log #1 with its front resting on log #4. 3.0 OPERATING GUIDELINES AND Note to Installer: Disconnect this appliance and ad- MAINTENANCE INSTRUCTIONS vise owner if any spillage or abnormal operation oc- Upon completing the gas line connection, a small curs which can't be rechecked immediately. amount of air will be in the lines. When first lighting the To obtain proper operation, it is imperative that the pi- pilot light, it will tak
Краткое содержание страницы № 13
SAFETY INFORMATION FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS ! EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROP- ERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE. A. This appliance has a pilot which must be lighted C. Use only your hand to push in or turn the gas by hand. When lighting the pilot, follow these in- control knob. Never use tools. If the knob will structions exactly. not push in or turn by hand, don’t try to repair it, call a qualified s
Краткое содержание страницы № 14
LIGHTING INSTRUCTIONS LIGHTING INSTRUCTIONS 1. "STOP!" Read the safety information on previous PILOT ASSEMBLY page. 2. Remove the control access cover. 3. Turn the valve control knob to the "OFF" position. To do this, you must turn the knob clockwise to the "Pilot" position, and then press in and continue turning 6. To put the control in the "Pilot" position, turn the clockwise to the "OFF" position. control knob counter-clockwise to the "Pilot" position. 7. To light t
Краткое содержание страницы № 15
GRL-850-AU Service Parts u (NG, LP) Exploded Parts Diagram Beginning Manufacturing Date: 4-2003 Ending Manufacturing Date: ________ 2 12 11 3 5 4 7 1 8 9 6 10 13 Log set assembly 14 18 19 20 16 17 15 Part number list on following page. 13
Краткое содержание страницы № 16
4.0 REPLACEMENT PARTS: GRL-850-AU When requesting service or replacement parts for your decorative gas log set, please provide model number and serial number. All parts listed in this manual may be ordered from an authorized dealer. ITEM Description SERIAL # PART NUMBER 1 ON/OFF Rocker Switch 060-521A 2 Burner NG 2011-003 2 Burner LP 2011-005 3 Burner Orifice NG 526-801 3 Burner Orifice LP 526-800 4 Piezo Ignitor 418-513 5 Valve NG 060-524 5 Valve LP 060-526 6 Access Door 2011-216 u 7 Flex Ga
Краткое содержание страницы № 17
LIMITED 10 YEAR WARRANTY HEAT-N-GLO, a brand of Hearth & Home Technologies Inc. In order to presumptively establish the dates to which your HEAT-N-GLO Limited Warranty runs, you must mail the completed warranty card to HEAT-N-GLO, a brand of Hearth & Home Technologies Inc., 20802 Kensington Boulevard, Lakeville, MN 55044, within 60 days of the date of the fireplace installation. If you fail to do so, you may be required to prove the date of installation before warranty work can be performed. The