Краткое содержание страницы № 1
SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY
THIS MANUAL IS PRINTED ON RECYCLED PAPER
EG 28 Direct Vent
By SHERWOOD INDUSTRIES
OWNERS MANUAL
WHAT TO DO IF YOU SMELL GAS
WARNING
• Open windows
If the information in this manual
• Do not try to light any appliance.
is not followed exactly, a fire or
explosion may result causing
• Do not touch any electrical switch; do not use any
property damage, personal
phone in your bui
Краткое содержание страницы № 2
SAFETY PRECAUTIONS FOR SAFE INSTALLATION AND OPERATION OF YOUR "ENVIROGAS" STOVE, PLEASE, CAREFULLY READ THE FOLLOWING INFORMATION: • To prevent injuries do not allow anyone who is GENERAL unfamiliar with the operation to use the stove. • Installation and repair should be done by a qualified service person. The appliance should • Always keep the appliance area clear be inspected before use and at least annually and free of combustible materials, gasoline by a qualified servic
Краткое содержание страницы № 3
TABLE OF CONTENTS Safety Precautions 2 Code Approvals 3 Deciding where to locate your stove 4 Planning your installation 6 Installation of Log Sets and Embers 14 Operating Instructions 15 Maintenance and Technical 16 Trouble Shooting 17 Gas Line Connection 18 Electrical 19 Parts and Accessories 20 Fuel Conversion 21 Warranty 22 Parts List 23 Exploded Views 24-25 Installation Data Sheet 26 Mobile Home Information 3,13,19,21 CODE APPROVALS • This Direct Vent appliance d
Краткое содержание страницы № 4
DECIDING WHERE TO LOCATE YOUR STOVE DIMENSIONS: Front Width: 22"/ 56 cm Rear Width: 22"/ 56 cm Height: 27-1/2"/ 70 cm* Depth 19"/ 48 cm (*not including vent coupling) Shipping Weight: 210 lbs/95 kg FIG. 1 CLEARANCES: A. Side wall to stove 10"/ 25 cm B. Rear wall to stove 4"/ 10 cm C. Combustible to stove Top 22”/ 56 cm D. Floor to stove 0"/ 0 cm E. Corner clearance 2"/ 5 cm F. Alcove depth 48"/ 122 cm Maintain sufficient clearances
Краткое содержание страницы № 5
VENT TERMINAL CLEARANCES A= Clearance above grade, verandah, porch, deck, or H= *Not to be installed above a meter/regulator assembly balcony [*12 inches (30 cm) minimum] within 3 feet (90 cm) horizontally from the center-line of B= Clearance to window or door that may be opened the regulator [*12 inches (30 cm) minimum] I= Clearance to service regulator vent outlet C= Clearance to permanently closed window [*6 feet (1.8m) minimum] [minimum 12 inches
Краткое содержание страницы № 6
These models have been tested and certified for use with SIMPSON DURAVENT DIRECT VENT TYPE "GS" PIPE FOR GAS STOVES. SECURITY VENTING SYSTEMS (SECURE VENT) Kits are available for vertical venting or horizontal venting. It is recommended that a bead of RTV High Temperature Silicone be applied to each outer vent joint and milpac to each inner joint before installation. This model has also been tested for horizontal venting installations when using SHERWOOD INDUSTRIES LTD. horizontal venting
Краткое содержание страницы № 7
When planning your installation, it will be necessary to select the proper length of vent pipe for your particular requirements. It is important to note when passing through a wall, the maximum allowable wall thickness is 10-inches (254mm), 1 ½ inches clearance to combustibles must be maintained. Select the amount of vertical rise desired for “vertical-to-horizontal” type installations. To determine the length of vent pipe required for vertical installations, measure the distance from the ap
Краткое содержание страницы № 8
STEP 7. Slide the decorative wall thimble up to the wall surface and attach with the screws provided. Apply decorative brass or chrome trim if desired. FIG-14. FIG. 11 FIG. 12 FIG-13 FIG-14 NOTES: (1) The four wood screws provided should be replaced with the appropriate fasteners for stucco, brick, concrete, or other types of siding. (2) For buildings with vinyl siding, a vinyl siding standoff (950), should be installed between the vent cap and the exterior wall
Краткое содержание страницы № 9
VERTICAL INSTALLATION STEP 1. Check the instructions for required clearances (air spaces) to combustibles when passing through ceilings, walls, roofs, enclosures, attic rafters , or other nearby combustible surfaces. Do not pack air spaces with insulation. STEP 2. Set the gas appliance in the desired location. Drop a plumb bob down from the ceiling to the position of the appliance flue exit, and mark the location where the vent will penetrate the ceiling. Drill a small hole at this poi
Краткое содержание страницы № 10
NOTES: (1) If an offset is necessary in the attic to avoid obstructions, it is important to support the vent pipe every 3 feet, to avoid excessive stress on the elbows, and possible separation. Wall straps are available for this purpose. FIG-18 (2) When ever possible, use 45° degree elbows instead of 90° degree elbows. The 45° degree elbow offers less restriction to the flow of flue gases and intake air. NOTES: (1) For multi story installations. A ceiling firestop (part 963) is required
Краткое содержание страницы № 11
CATHEDRAL CEILING INSTALLATION STEP 1. Follow installation steps 1 and 2 under Vertical Termination. STEP 2. Using the plumb bob, mark the centerline of the venting system on the ceiling and drill a small hole through the ceiling and roof at this point. From the roof, locate the drill hole and mark the outline of the “Cathedral Ceiling Support Box”. STEP 3. Remove shingles or other roof coverings as necessary to cut the rectangular hole for the “Support Box”. Cut the hole 1/8” larger
Краткое содержание страницы № 12
Install 2 spring spacers around the flex pipe. Slide the horizontal section of pipe over the flexible liner and install through the wall thimble, ensure that this portion of pipe slides onto the vent termination cap. Slide the inside finished collar over the horizontal section of pipe and secure to wall using the screws provided. Slide the 90° elbow over the flex pipe. Stretch the flex liner to a length long enough to ensure the flex liner can be easily connected to the flue outlet of the
Краткое содержание страницы № 13
VENTING INTO CLASS “A” CHIMNEYS Simpson GS Dura This model is also certified and tested to vent into vent cap CLASS “A” wood. stove chimneys Cap Adapter Place the freestanding direct vent appliance in the desired location. Using Simpson Dura Vent conversion kit #s 931-932- Class “a Chimney 933, depend on the ID diameter of the CLASS “A” chimney that this appliance is to be vented into. Place a bead of high temperature silicone or mil pac at each connection to e
Краткое содержание страницы № 14
INSTALLATION OF LOGSET and EMBERS INSTALLATION OF LOGSET and EMBERS INSTALLING THE GLOWING EMBERS INSTALLING THE GLOWING EMBERS A bag of Rock Wool embers is provided for use on the burner. A bag of Rock Wool embers is provided for use on the burner. CAUTION: Use only the type of ember material supplied with CAUTION: Use only the type of ember material supplied with this appliance. Due to the amount of ember material this appliance. Due to the amount of ember material there may b
Краткое содержание страницы № 15
OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE OPERATING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A) This appliance is equipped with a pilot, which must be lit by • If you cannot reach your gas supplier, call the fire hand by following these instructions exactly. department. B) BEFORE LIGHTING smell all around the appliance area C) Use only your hand to push in or turn the
Краткое содержание страницы № 16
MAINTENANCE AND TECHNICAL To Replace: Periodically check to ensure that your "Direct Vent" • open door fully system is clear. • Lift door vertically so that hinge pins lift out of hinge receivers. Periodically check the pilot and burner. Check to see • Return the door assembly to dealer. that all the burner ports are clean and clear. Check Door and glass assembly must be replaced as a the pilot head for blockage. Check to ensure the pilot complete unit by your ENVIROGAS Dea
Краткое содержание страницы № 17
TROUBLE SHOOTING Problem Possible Cause Solution Spark will not light the pilot after Defective piezo igniter Check connections to igniter repeated pressing of spark igniter -If igniter connections are good but there is no spark-replace igniter Broken spark electrode -Check for broken ceramic insulation replace, electrode if broken Miss-aligned spark electrode -If spark is not arcing from the electrode to pilot- adjust by loosening screws on pilot base. Adjust and re- tighten Pilo
Краткое содержание страницы № 18
GAS LINE CONNECTION ORIFICE SIZES, PRESSURE AND BTU’S NATURAL GAS PROPANE GAS Main Orifice #42 dms #53 dms Manifold pressure. 3.8” wc (0.95 kPa) 11” wc (2.74 kPa) Min. Manifold pressure. 1.1” wc (0.27 kPa) 2.7” wc (0.67 kPa) Supply Pressure. 7.0” wc (1.74 kPa) 12” wc (2.98 kPa) Min. Supply pressure. 5” wc (1.25 kPa) 11.5” wc (2.86 kPa) Max. BTUH Input. 26,500 Btu/h(7.87 kW) 26,500 Btu/h(7.87 kW) Min. BTUH Input. 13,500 Btu/h(3.9 kW) 13,500 Btu/h(3.9 kW) Output fan off 21,0
Краткое содержание страницы № 19
The ENVIROGAS EG 28.FS.DV. will operate with no external power supply. These models have a Millivolt gas control which uses the pilot flame to generate enough electricity to operate the main burner. The appliance when installed, must be electrically connected and grounded in accordance with local codes or in the absence of local codes, with the current CSA C22.1 CANADIAN ELECTRICAL CODE. Part 1, SAFETY STANDARDS FOR ELECTRICAL INSTALLATIONS, or THE NATIONAL ELECTRICAL CODE ANSI / NFPA 70 i
Краткое содержание страницы № 20
PARTS AND ACCESSORIES Service Parts available from your local Envirogas Dealer Burner Control Assembly Convection Blower Natural Gas Pilot Assembly Light Bulb Holder Propane Pilot Assembly Light Switch (momentary) Door Bolt Fan Controller Relief Door Gasket Log Set (with Embers) Regulating Valve Thermocouple Piezo Igniter Embers Burner Switch Thermopile Door Gasket B-vent Spill switch 220° Orifice Blank Convection Fan Sensor 120° (48°C) Accessories Gold trim Package Low